Sie sind auf Seite 1von 1

Mix Design adopted for M80 Grade of concrete

Basic Materials Without ALCCOFINE 1203 With ALCCOFINE 1203


Cement 460 460
Silicafume 50
ALCCOFINE 1203 50
FLY ASH 80 80
Cost benefit analysis for a standard Mix of M80 with Alccofine 1203 vis a
vis silicafume fromLocally available market
Mix Design adopted for M80 Grade of concrete
FLY ASH 80 80
Water 145 145
AGG 20mm 607 586
AGG 10mm 518 502
Natural Sand 600 611 Item Rateper Kg Cement+Silicafume+FA Cost /Cum Cement+ALCCOFINE 1203+FA Cost per Cum
Admixture doses 1.10% 0.90% Cement 5 460 2300 460 2300
Cost Benefit analysis with ALCCOFINE 1203 MIX
MIX Without ALCCOFINE 1203-A MIX With ALCCOFINE 1203-B
Silicafume 25 50 1250 0
ALCCOFINE 1203 25 0 50 1250
Fly Ash(FA) 1.5 80 120 80 120
Admixture Dose 1.10% 0.90% Admixture 130 6.49 843.7 5.31 690.3
Rs 4513.7 Rs 4360.3
(a) Initial Collapse Collapse
1 34
Fresh Concrete Properties: (Workabillity)
Result obtained M80 Grade of concrete
(b) 30 Min Collapse Collapse Net Savings / cum(A - B) =Rs 4772.1-Rs 4401.7)=Rs 153.4
60 min 150 165 Note:
(d) 90 Min 130 140 The Mix is for M80 Grade of concrete done at ACC Concrete.
(e) 120 Min 100 110 Admixture used is PC based admixture in both the mixes with same per Kg rate considered
(e) 180 Min 90 100 The rates taken are based on Mumbai market and an avg of prevaling market prices in first half of 2012 year.
It is observed that ALCCOFINE 1203 reduces PC Based Admixture demand in high grade concrete. Hardended Concrete Properties: (Compressive strength) g g
(i) 1 Day 25 29 It is also observed because of cementetious constituent present in ALCCOFINE 1203 , it futher optimizes the does of total
(ii) 3 days 45 49 Cementetious content in concrete.
(iii) 7 days 70 74 It is witnessed that silicafume comes in Condensed formand is in need of colloidal Mixer for Dedensifying the same
(iv) 28 days 83 88 If not done properly may result into higher consumption of Admixture resulting in to cost increase of concrete.
p ( p g )

Das könnte Ihnen auch gefallen