Sie sind auf Seite 1von 109

UniTest for Excel

Example Case

Gage Gage Gage Gage MVMNT


#1
#2
#1
#4
Average
unit unit unit unit

LOAD

MVMNT

(kips)

(inch)

LOAD (KN)

2,000
1,500
1,000
500
0
10

20

30

40

MOVEMENT (mm)

324 mm

Length

16.2 m

Wall

9.5 mm

Toe Diam.

324 mm

Modulus, E

205 GPa

4.448

25.4

CHIN

LOAD
(KN)

MVMNT
(mm)

mvmnt/load

0
89
178
267
356
445
534

0.00
0.28
0.81
1.27
1.78
2.41
3.15

3.1
4.6
4.8
5.0
5.4
5.9

623

3.99

6.4

712
801
890
979
1,068
1,157

4.98
5.84
6.78
7.87
8.94
10.03

7.0
7.3
7.6
8.0
8.4
8.7

1,245
1,334
1,423
1,512
1,601
1,690
1,779
1,868

11.15
12.24
13.84
15.49
20.52
26.42
36.83
53.34

9.0
9.2
9.7
10.2
12.8
15.6
20.7
28.6

(mm/N)
1,000

2,500

Diameter

50

60

As =

2
1.017 m /m

94.1 cm

823.7 cm

94 cm

Ac =
At =
Aw =
EA/L =
Hansen

OFFSET LIMIT LOAD

119 KN/mm
Decourt

(mvmnt)/load (load/mvmnt)

(mm/N)

(N/mm)

1,000

CHIN

Hansen

Decourt

Qcalc.

Qcalc.

Qcalc.

Simulated Curves

(KN)

(mm)

at X-axis =

6.7

end of line =

1,868

22.35

Offset Limit =

1,595

20.06

CHIN
mvmnt/load

MVMNT

1st =

28.55

53.34

C1 =

2nd =

10.24
2,072

15.49

C2 =

5.9
5.1
4.2
3.7
3.5
3.3

318.4
218.9
210.2
200.1
184.3
169.5

93
250
366
479
600
720

243
410
509
598
690
780

96
256
373
487
610
730

R-ult=

3.2

156.2

834

868

3.1
3.0
2.9
2.9
2.8
2.7

143.0
137.1
131.2
124.3
119.4
115.3

947
1,029
1,106
1,183
1,247
1,303

2.7
2.6
2.6
2.6
2.8
3.0
3.4
3.9

111.7
109.0
102.8
97.6
78.0
64.0
48.3
35.0

1,353
1,397
1,451
1,499
1,608
1,693
1,785
1,865

inv.slope =

Hansen
(mvmnt)/load

MVMNT

1st =

3.91

53.34

C1 =

845

2nd =

12.82

20.52

C2 =

956
1,023
1,088
1,155
1,213
1,267

957
1,039
1,116
1,192
1,255
1,311

R-ult=

1,871

1,316
1,360
1,417
1,469
1,592
1,691
1,794
1,861

1,361
1,403
1,457
1,504
1,611
1,693
1,783
1,861

u = C2/C1 =

Decourt
load/mvmnt

MVMNT

1st =

35.03

53.34

C1 =

2nd =

97.61
2,061

15.49

C2 =

R-ult=

QChin
QHansen

QDecourt

C1 C 2

C1 C2

C 2
1 C1

0.4826
2.857

120

y = 0.4826x + 2.8571
R = 0.9999

30

LOAD/MVMNT (MN/mm)

2,072

MVMNT/LOAD (mm/MN)

35

25
20
15
10
CHIN

Chin

0
0

0.0329

20

40

60

MOVEMENT (mm)

2.170

66.0

-0.1741
358.88

(MVMNT)/LOAD ((mm)/MN)

4.5
y = 0.0329x + 2.1704
R = 0.998

4.0
3.5
3.0
2.5
2.0

1.5
HANSEN

1.0
0.5

Hansen

0.0
0

20

40

MOVEMENT (mm)

60

y = -0.1741x + 358.88
R = 0.9953

100
80
60

DECOURT

40
20
0
0

500

y = -0.1741x + 358.88
R = 0.9953

DECOURT

500

1,000
LOAD (KN)

1,500

2,000

..

2,500

Decourt

0 2,061
35 1,868

LOAD (KN)

2,000
1,500
1,000
500
0
0

10

20

30

40

MOVEMENT (mm)
Hansen 1,871
1,871

74
70

Chin 2,072
2,072

74
70

Decourt 2,061
2,061

74
70

Davisson 1,595
1,595

74
70

50

60

30.0

7.0
(MVMNT)/LOAD ((mm)/MN)

MVMNT/LOAD (mm/MN)

CHIN-KONDNER

25.0
20.0
Inv.Slope
2,067 KN

15.0
10.0
5.0

HANSEN

6.0
5.0
4.0

3.0
2.0
1.0
0.0

0.0
0

20

40

MOVEMENT (mm)

60

20
MOVEMENT (mm)

350
LOAD/MVMNT (MN/mm)

DECOURT

300
250
200

150
100
50
0

40

MOVEMENT (mm)

60

1,000

2,000

LOAD (KN)

3,000

..