0 Bewertungen0% fanden dieses Dokument nützlich (0 Abstimmungen)
379 Ansichten14 Seiten
The document provides instructions for connecting to a Siemens S7 PLC using OPC Scout software. It describes creating a connection to the PLC, adding symbolic addressing when creating a data block, and monitoring PLC data items in OPC Scout by dragging symbols or using the OPC syntax of Protocol:[connection]item. The goal is to explore and monitor PLC symbols and data through the OPC Scout interface.
The document provides instructions for connecting to a Siemens S7 PLC using OPC Scout software. It describes creating a connection to the PLC, adding symbolic addressing when creating a data block, and monitoring PLC data items in OPC Scout by dragging symbols or using the OPC syntax of Protocol:[connection]item. The goal is to explore and monitor PLC symbols and data through the OPC Scout interface.
The document provides instructions for connecting to a Siemens S7 PLC using OPC Scout software. It describes creating a connection to the PLC, adding symbolic addressing when creating a data block, and monitoring PLC data items in OPC Scout by dragging symbols or using the OPC syntax of Protocol:[connection]item. The goal is to explore and monitor PLC symbols and data through the OPC Scout interface.
Tell that you want to use symbols (not mandatory, but easier later on)
Example no liability of any kind Create S7 connection
You can give the connection a name (local ID)
this name appears in the OPC syntax later on
Example no liability of any kind Here we create a DB with symbolic addressing
Example no liability of any kind Just a small PLC program to animate the data in OB35
Example no liability of any kind VAT table
Not mandatory
Just to be able to see the symbols and the data
Example no liability of any kind Compile HW again
Example no liability of any kind Download HWConfig to the PC
To be sure you have the symbols loaded in the OPC
Example no liability of any kind OPC Scout 2008 V10 - Explorer exploring symbols
Example no liability of any kind OPC Scout 2008 V10 Explorer Exploring S7 connection You cannot add items here Adding items takes place in the data views See next slides
Example no liability of any kind Drag and drop OPC Scout 2008 V10 Workbook - Add a server to your project
Example no liability of any kind Drag and drop OPC Scout 2008 V10 Workbook - Add items using symbols by drag and drop
Example no liability of any kind Follow the classical syntax Protocol:[connection]item OPC Scout 2008 V10 Workbook - Add items using the OPC syntax
Example no liability of any kind OPC Syntax for S7
Example no liability of any kind OPC Scout 2008 V10 Workbook - Monitor the added items