Sie sind auf Seite 1von 10

Cell 1 AQFD

Comparison of Cell 1 and Cell 12 Air Quench From Die


2 Data classification: Internal 02/21/2014
Abdalla Fares-Hammad/Greg Rausch
TS Temp: 200C Or below
TS air speed: 15 m/s minimum


Temperature reading
ODD Tray: 270 C, 303 C
Even Tray: 290 C, 395 C


Cell # 1A
Air Flow in meters/second



3 Data classification: Internal 02/21/2014
Abdalla Fares-Hammad/Greg Rausch
TS Temp: 200C Or below
TS air speed: 15 m/s minimum


Temperature reading
ODD Tray: 300 C, 298 C
Even Tray: 300 C, 280 C

Cell # 1B
Air Flow in meters/second
4 Data classification: Internal 02/21/2014
Abdalla Fares-Hammad/Greg Rausch

Cell 1 AQFD/WQFD Machine
5 Data classification: Internal 02/21/2014
Abdalla Fares-Hammad/Greg Rausch
TS Temp: 200C Or below
TS air speed: 15 m/s minimum


Temperature at one cycle
ODD: 280 C, 276 C
Even: 290 C, 280 C

Cell #12A
Air Flow in meters/second

6 Data classification: Internal 02/21/2014
Abdalla Fares-Hammad/Greg Rausch
TS Temp: 200C Or below
TS air speed: 15 m/s minimum


Temperature at one cycle
ODD: 267 C, 286 C
Even: 290 C, 295 C

Cell #12-B
Air Flow in meters/second

7 Data classification: Internal 02/21/2014
Abdalla Fares-Hammad/Greg Rausch
TS Temp: 200C Or below
TS air speed: 15 m/s minimum


Temperature at Two cycles
ODD: 150 C, 140 C
EVEN: 157 C, 150 C

Cell #12-A
Air Flow in meters/second

8 Data classification: Internal 02/21/2014
Abdalla Fares-Hammad/Greg Rausch
TS Temp: 200C Or below
TS air speed: 15 m/s minimum



Temperature at Two cycles
ODD: 177 C, 175 C
EVEN: 170 C, 169 C

Cell #12-B
Air Flow in meters/second

9 Data classification: Internal 02/21/2014
Abdalla Fares-Hammad/Greg Rausch

Cell 12 AQFD Machine
10 Data classification: Internal 02/21/2014
Abdalla Fares-Hammad/Greg Rausch
We need strip temperature from cell 1 and 12.
Single cavity cycle time is 88 seconds
Dual cavity cycle time is 93 seconds
Notes

Das könnte Ihnen auch gefallen