The document provides specifications for installing a chain link fence. It specifies that the fence will be made of 50mm wire mesh with a 3.55mm diameter and galvanized. Posts will be spaced no more than 3 meters apart and will include straining posts at ends, corners, and every 30 meters. It also provides details on the types of posts that can be used, how the wire mesh and lines wires will be attached to the posts, and other installation details.
The document provides specifications for installing a chain link fence. It specifies that the fence will be made of 50mm wire mesh with a 3.55mm diameter and galvanized. Posts will be spaced no more than 3 meters apart and will include straining posts at ends, corners, and every 30 meters. It also provides details on the types of posts that can be used, how the wire mesh and lines wires will be attached to the posts, and other installation details.
The document provides specifications for installing a chain link fence. It specifies that the fence will be made of 50mm wire mesh with a 3.55mm diameter and galvanized. Posts will be spaced no more than 3 meters apart and will include straining posts at ends, corners, and every 30 meters. It also provides details on the types of posts that can be used, how the wire mesh and lines wires will be attached to the posts, and other installation details.
1. EXCEPT WHERE OTHERWISE MODIFIED THECHAIN LINK FENCE SHALL
GENERALLY BE IN ACCORDANCE WITH B.S. 1722 PART 10 AND B. S. 4102. 2. THE CHAIN LINK FENCING SHALL BE OF 5 0mm WIRE MESH TO A NET GAUGE OF 3.55mm DIA. AND GALVANISED. 3. ALL POSTS SHALL BE SPACED AT NOT MORE THAN 3 METRES APART. 4. STRAINING POSTS SHALL BE SPACED EQUA LLY AND PROVIDED AT ALL ENDS AND CORNERS, AT CHANGES IN DIRECTION ORACUTE VARIATIONS IN LEVEL AND AT INTERVALS NOT EXCEEDING EVERY TEN POST IN STRAIGHT LENGTHS OF FENCE THAT IS 30 METRES. 5. ALL BOLTS, NUTS, STAPLES AND WASHERSSHALL BE PLATED OR COATED WITH STAINLESS METAL. 7. THE BARBED WIRE SHALL CONSIST OF 2 PLY DIA. 2.5mm STEEL WIRE WITH 8. ALL M.S. POSTS, STRUTS, ETC. SHALL B DIP PROCESS AFTER FABRICATION. HOLDING DOWN THE WIRE MESH. 11. ALL STRUCTURES ABOVE GROUND TO BE AT LEAST 2.3 METRES CLEAR OFF ALL BOUNDARIES. PLASTIC COATED GALVANISED WIRE CHAIN LINK FENCING OUTSIDE DIA. mm CORE DIA. mm CHAIN LINK FENCING LINE WIRE STIRRUP WIRE TYING WIRE 4.75 3.55 4.75 3.55 3.55 2.00 2.50 1.40 TABLE 1 : SIZES OF WIRE CHAIN LINK FENCING CORNER POST POSITION AND TYPE OF GATE DEPENDING ON LOCATION AND SIZE OF PLANT TYPICAL SITE PLAN OF CHAIN LINK FENCE x x x x x x x x x x x x 75 75 8 0 0 2 8 9 0 7 5 0 2 4 0 0 5 0 2 5 2 5 75 75 8 0 0 8 0 08 0 0 2 8 9 0 2 4 5 0 1 5 0 7 0 0 7 0 0 7 0 0 1 5 0 3 2 0 0 2 0 0 2 0 0 6 2 0 8 0 0 2 4 5 0 8 0 0 2 8 9 0 7 5 0 2 4 0 0 5 0 2 5 75 75 1 0 0 0 0 6 STIRRUP AT 300 CRS CHAIN LINK MESH CHAIN LINK MESH SECURED BY 25x5 M.S. FLAT CLAMP BARS 4 NUMBERS 0 10 BARS CONCRETE 450x450x800 DEEP LINE WIRE 3 COMPLETE TURNS 0 10 HOLE 0 6 STIRRUP AT 300 CRS 4 NUMBERS 0 10 BARS 64x64x5 M.S. ANGLE 76x76x6 M.S. ANGLE BARBED WIRE 6mm THICK M.S. PLATE WELDED AT ENDS 64x64x6 M.S. ANGLE 76x76x6 M.S. ANGLE 2450x25x5 CLAMP BAR BARBED WIRE CHAIN LINK FENCING CORNER POST CORNER POST M10 0 STEEL BOLT WELDED 76x76x6 M.S. ANGLE 44x44x5 M.S. STRUT WELDED TO 150x150x5 M.S. PLATE 44x44x5 M.S. ANGLE 76x76x6 M.S. ANGLE CHAIN LINK FENCING M8 0 STEEL BOLT 25x5 CLAMP BAR STEEL POST CHAIN LINK FENCING 0 5 HALF ROUND STAPLES OR 0 2.5 PLASTIC COATED STIRRUP WIRE LINE WIRE / / / / 45 25 25 100 45 / / INTERMEDIATE POST 45 7 0 5 7 5 6 2 0 7 5 7 5 7 5 7 5 2 0 0 2 0 0 7 0 5 7 5 70 2 0 0 2 0 0 45 6 2 0 / / / / 20mm COVER TO REINFORCING BARS 150x150 100x125 x x x x x x 200 2 0 0 70 450x450 450x450 CUT ENDS OF PLASTIC COATED GALVANISED WIRE CHAIN LINK FENCING TO BE THERMAL SEALED CHAIN LINK FENCING MESH SIZE 50mm WIRE DIA. 3.55mm ( SEE TABLE 1 ) R.C. CORNER POST ( 150x150x3.2m ) R.C. STRUT ( 100x100x3.25m ) R.C. INTERMEDIATE POST ( 125x100x3.2m ) 2 NOS. LINE WIRE ( SEE TABLE 1 ) TO BE THREADED THROUGH CHAIN LINK MESH LINE WIRE TO BE THREADED THROUGH CHAIN LINK MESH R.C. STRUT ( 200x100x3.25m ) LINE WIRE TO BE THREADED THROUGH CHAIN LINK MESH R.C. INTERMEDIATE POST ( 125x100x3.2m ) LINE WIRE TO BE THREADED THROUGH CHAIN LINK MESH R.C. STRAINING POST ( 150x150x3.2m ) TYING WIRES AT 450 CRS FOR SECURING CHAIN LINK FENCING TO LINE WIRE (150 CRS FOR TOP & BOTTOM LINE WIRE) R.C. STRUT (100x100x3.25m) CHAIN LINK FENCING MESH SIZE 50mm WIRE DIA. 3.55mm ( SEE TABLE 1 ) CORNER POST INTERMEDIATE POST INTERMEDIATE POST 44x44x5 M.S. STRUT LENGTH 3.15m STRAINING POST 44x44x5 M.S. STRUT LENGTH 3.15m 2 5 0 250 600x300 450x450 8 0 0 8 0 0 8 0 0 8 2 0 75 75 8 0 0 7 5 0 8 0 0 8 0 0 8 0 0 2 NOS. LINE WIRE ( SEE TABLE 1 ) TO BE THREADED THROUGH CHAIN LINK MESH LINE WIRE TO BE THREADED THROUGH CHAIN LINK MESH TYING WIRES AT 450 CRS FOR SECURING CHAIN LINK FENCING TO LINE WIRE (150 CRS FOR TOP & BOTTOM LINE WIRE) 8 2 0 LINE WIRE TO BE THREADED THROUGH CHAIN LINK MESH LINE WIRE TO BE THREADED THROUGH CHAIN LINK MESH 75 75 8 0 0 600x300 450x450 250 3 0 0 CHAIN LINK FENCE WITH CONCRETE POSTS DETAIL FOR SECURING LINE WIRE TO STEEL POST ELEVATION PLAN SCALE 1 : 100 DETAIL Y : FIXING STRUTS TO STEEL POSTS FRONT VIEW END ELEVATION SCALE 1 : 2 DETAIL Z INTERMEDIATE POST CORNER AND STRAINING POSTS INTERMEDIATE POST CORNER AND STRAINING POSTS DETAIL X : STIRRUP FIXING IN CONCRETE POST ELEVATION PLAN A-A DETAIL OF FIXING STRUTS TO CONCRETE POSTS SCALE 1 : 10 ARRANGEMENT OF CONCRETE POSTS AT CORNER CONCRETE POSTS STEEL POSTS SEE DETAIL Z 3.0m MAX. 3.0m MAX. 3.0m MAX. 3.0m MAX. CUT ENDS OF PLASTIC COATED GALVANISED WIRE CHAIN LINK FENCING TO BE THERMAL SEALED 2 PLY 0 2.5 STEEL WIRE WITH 4 POINT BARBS SPACED AT 75mm APART 2 5 CHAIN LINK FENCE WITH STEEL POSTS / / 44x44x5 M.S. ANGLE WELDED TO 44x44x5 M.S. ANGLE EXTENSION ARM M 8 0 BOLT SECURING CLAMP BARS 51x51x6 M.S. ANGLE WELDED TO 51x51x6 M.S. ANGLE EXTENSION ARM WIRE STIRRUP PASSED THROUGH A HOLE IN POST AND SECURED TO THE WIRE WITH 3 COMPLETE TURNS ON EACH SIDE OF POST ( SEE DETAIL X ) 0 3.55 PLASTIC COATED STIRRUP WIRE SCALE 1 : 5 2 5 6 2 0 45 2 9 4 0 x 45 3 2 0 0 6. LINE WIRE SHALL BE TO A NET GAUGE OF 3.55mm DIA. AND GALVANISED. 4 POINT BARBS SPACED AT 75mm APART AND GALVANISED. 9. 25mm x 5mm CLAMP BARS TO BE USED ON ALL STRAINING POSTS FOR 3 NUMBERS M 13 0 BOLTS E HEAVILY GALVANISED BY THE HOT / 12. ALL CONCRETE TO BE GRADE 25 AND ABOVE UNLESS OTHERWISE SPECIFIED. 76 x 76 x 6 M.S. ANGLE 10 x 100 GALV. M.S. EYE BOLT M5 STAINLESS STEEL TURNBUCKLE BARBED WIRE OR LINE WIRE BARBED WIRE OR LINE WIRE LOCKING NUT CHAIN LINK FENCE CONCRETE POST 10 x 245 GALV. M.S. EYE BOLT M5 STAINLESS STEEL TURNBUCKLE CHAIN LINK FENCE LOCKING NUT 0 13 INTERNAL GALV. M.S. SLEEVE / SCALE 1 : 3 SCALE : FULL SIZE SCALE : FULL SIZE SCALE 1 : 3 DETAIL W : FIXING STRAINING LINE WIRE DETAIL V : FIXING STRAINING LINE WIRE & BARBED WIRE SEE DETAIL V SEE DETAIL W SEE DETAIL V SEE DETAIL V PILES AND FOUNDATION TO ENGINEERS DETAILS PILES AND FOUNDATION TO ENGINEERS DETAILS SEE DETAIL Y STANDARD 2.4 METRES HIGH CHAIN LINK FENCE [ ORIGINAL BORDER SIZE 810mm X 565mm ] DRG. NO. SCALES 10. ALL LINE WIRES CHAIN LINK FENCING AND BARBED WIRES SHALL BE PROPERLY STRAINED. 2.3M (MIN.) 2 .3 M ( M I N .) 2.3M (MIN.) 2 .3 M ( M I N .) PUB/WRN/STD/105 1 : 20 UNLESS OTHERWISE STATED WATER RECLAMATION (NETWORK) DEPARTMENT Water for All:Conserve,Value,Enjoy ISSUED BY WATER RECLAMATION (NETWORK) DEPARTMENT ON APR 05