Session name: RELIANCE INDUSTRIES LIMITED-HAZIRA (E1-122A ZONE1) Date of inspection: 13/Sep/2013 Inspection site: RELIANCE INDUSTRIES LIMITED-HAZIRA End customer: RELIANCE INDUSTRIES LIMITED-HAZIRA Company performing inspection: ARUDRA ENGINEERS PVT LIMITED -CHENNAI Description of inspection: ACOUSTIC EYE Inspected equipment: HEAT EXCHANGER E1-122A ZONE1(TOP TO BOTTOM) Inspection technicians: N.MURALITHARAN Inspection witnesses: T.THIAGARAJAN Report produced by: T.THIAGARAJAN Thresholds: Blockages cross-section reduction threshold: 5.0% Erosions wall reduction threshold: 5.0% Pittings wall reduction threshold: 20.0% Summary: Signature: ________________ Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 1 of 14 2D Map Legend Name Value Holes Blockages Erosions Pittings Unknown No faults detected Not inspected Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 2 of 14 Custom pictures Picture: RIL-HAZIRA E1-122A ZONE1 Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 3 of 14 Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 4 of 14 Defect tables by type Blockages Tube ID Pos[m] Cross Section Reduction[%] Condition Comments Displayed Filter Graph R[2]C[7] 0.681 1.34 Sub-threshold blockage None Link R[5]C[5] 0.769 1.77 Sub-threshold blockage None Link R[5]C[11] 1.9 1.02 Sub-threshold blockage None Link R[6]C[1] 3.07 3 Sub-threshold blockage None Link R[7]C[1] 0.769 1.53 Sub-threshold blockage None Link R[8]C[21] 0.366 1.49 Sub-threshold blockage None Link Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 5 of 14 Erosions Tube ID Pos[m] Wall Reduction[%] Condition Comments Displayed Filter Graph R[3]C[7] 0.242 4 Sub-threshold erosion None Link R[4]C[5] 1.83 4.2 Sub-threshold erosion None Link R[5]C[10] 1.22 2 None Link R[5]C[17] 0.341 3.8 None R[6]C[12] 3.1 2 Sub-threshold pit None Link R[8]C[1] 0.554 3.06 Re-Assigned None Link R[8]C[20] 0.348 3 Sub-threshold pit None Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 6 of 14 Signals - Blockages Filter: None Filter: None Filter: None Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 7 of 14 Filter: None Filter: None Filter: None Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 8 of 14 Signals - Erosions Filter: None Filter: None Filter: None Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 9 of 14 Filter: None Filter: None Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 10 of 14
General Technology Introduction Pulse Reflectometry (PR) is based on measurements of one dimensional acoustic waves propagating in tubes. Schematically: Any change in the cross sectional area in the tubular system creates a reflection. All reflections propagate back and the proprietary algorithms enable self-analysis. Each defect has its own signature, for example an erosion signature will look like this: As a result the APR gives exact location, type and size of the defect.
What can we learn from reflections? Reflections are created whenever a change in cross section is encountered: Constrictions: a reduction in cross section due to a partial blockage or a connector to a narrower pipe. Expansions: erosion or connection to a wider pipe. Effective changes in cross section due to openings into the atmosphere - such as holes and cracks. Schematically: Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 11 of 14
More typically, we will have: a local blockage (deposits, dents, welding material):
or degradation (pitting):
Schematically:
Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 12 of 14 Some actual signal examples: A hole: Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 13 of 14 Tube wall degradation:
The technology advantages: Non-traversing. FAST Inspection. Any pipe configuration (narrow, fin tubes, y & t joints, 90 turns). Non-material dependent inspects all: carbon, stainless, copper or brass. Easy to operate. Results analysis is simple.
The technology disadvantages: Only Inner diameter defects are being detected outer diameter isnt inspected. Arudra Engineers Pvt Ltd, 79, Valmiki Street, Thiruvanmiyur Chennai, Tamil Nadu, India Report number: 1 Page 14 of 14