Sie sind auf Seite 1von 1

UP DN

STAND-BY GENERATOR
GENERATOR
SERVICE
LIFT FIRE
LIFT
UP DN
UP
DN
E
X
P
A
N
S
IO
N
J
O
IN
T
E
X
P
A
N
S
IO
N
J
O
IN
T
TEMPORARY
FOUL TANK
OPEN BELOW
S
W
T
-3
SWT-1
OPEN
BELOW
PIT PIT
R
A
M
P
U
P

R
A
M
P
U
P

HANDICAP PARKING = 2 CARS
CAR PARK = 147 CARS
TOTAL CAR PARK = 149 CARS
R
A
M
P
U
P

B1-01-01
LIFT LOBBY
B1-01-10
STORAGE
ROOM
SMOKE
STOP LOBBY B1-02-02
B1-02-01
STAIR 07
B1-01-02
WATER FEATURE
MECH. ROOM
B1-01-03
FWT-1
B1-01-04
FWT-2
B1-01-05
LAUNDRY STEAM
BOILER ROOM
B1-01-06
STEAM
BOILER
CONTROL
ROOM
B1-01-07
SWT-2
B1-01-15
MC C
B1-01-14
E L V
B1-01-13
FIRE PUMP ROOM
B1-01-21
QTEL ROOM
B1-01-22
MV ROOM
B1-02-05
FUEL TANK
ROOM
B1-02-04
GENERATOR ROOM
FIRE
FIGHTING
LOBBY
B1-01-11
STORAGE
B1-01-12
CORRIDOR
B1-01-09
STAIR 02
B1-01-08 SERVICE
LIFT
LOBBY
B1-01-20
ELECT.
ROOM
B1-01-16
SMOKE STOP
LOBBY
B1-01-18
STAIR 03
B1-01-19
FOAMTANK
ROOM
B1-01-17
B1-02-06
GAS TANK
B
1-02-03
B1-02-07
OWNER'S GARAGE
B1-02-07A
GARAGE
F2 F2
F3 F3
F8
F2
F8
F3 F3 F3
F3 F3 F3
F2
F2
F18 F18
F18
F18 F18
F18
F2
F2
F2
F2
F8
F2
F2E
F2E
F8E
F8E
F8E F8E F8E
F18E
F2E
F6E
F6E
F6E
F6E F6E
F6E F6E
F2E
F18E
F2E
F8E
F8
F2
F2E
F2E
F2E
F18E F18E
F18E
F18E
F18E
F18
F18E
F18E
F4E
F4E
F18E
LCP
CBU
L1
L1E
L1
L1
L1
L1 L1 L1 L1 L1 L1 L1 L1 L1 L1E
L1
L1
L1 L1 L1 L1 L1 L1
L1 L1 L1 L1 L1 L1 L1 L1E L1E L1E L1E L1E L1E L1E
L1
L1
L1E
L1E
L1
L1
L1E
L1E
L1
L1
L1E
L1E
L1 L1 L1 L1 L1 L1 L1 L1 L1E L1E L1E L1E L1E L1E
L1 L1 L1 L1 L1 L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1 L1 L1 L1
L1E
L1E L1E L1E L1E
L1E
L1E L1E
L1E
L1E L1E L1E L1E
F2
L1 L1 L1E
L1 L1
L1E
L1E
E E
L1E
1ST BASEMENT FLOOR PLAN
LIGHTING
Issue Purpose
Date Started
Scale
DESCRIPTION REV DATE
NOTES
DISCIPLINE, AREA CODE &SHEET NUMBER
REVISION NUMBER STAGE PHASE PROJ ECT NO
Date Issued
Drawn
Checked
Approved
THIS DRAWING MUST NOT BE USED FOR CONSTRUCTION UNLESS
STAMPED AND SIGNED ISSUED FOR CONSTRUCTION AS APPROVED.
E
D
C
B
A
1 2 3 4 5 6 7
E
D
C
B
A
1 2 3 4 5 6 7
E
D
C
B
A
THIS DRAWING IS THE PROPERTY OF M.Z. & PARTNERS AND SHALL
NOT BE COPIED OR REPRODUCED IN ANY MANNER WITHOUT
THE WRITTEN CONSENT OF MZ & PARTNERS.
ARCHITECTURAL
STRUCTURAL
ELECTROMECHANICAL
SUPERVISION
PROJ ECT MANAGEMENT WLL
TEL:44 363813-4 P.O.B: 5785-QATAR , 44 360764-5 FAX:44 363812
AL BROOQ TOWER
PIN NO.63120028 (3B+G+M+43+S)
H.E. ABDUL RAHMAN AL ATTI YAH
ISSUED FOR CONSTRUCTION
SEPTEMBER 2012
SEPTEMBER 2013
SVA
LRL
VGK
1:200
12228 -- IFC
00
EL-1030
Sheet Size : A1 Monday, October 07, 2013 4:49:20 PM File Name : 1ST BASEMENT FLOOR PLAN LIGHTING.dwg Ploted By : Shameer Aboo
SCALE
1ST BASEMENT FLOOR PLAN LIGHTING
1
EL-1030 1:200
B
A
A
B
4 2
3
1. THIS DRAWINGS SHALL BE READIN CONJ UNCTION WITH ALL
RELEVANT DOCUMENTS, PROJ ECT SPECIFICATIONS ANDDRAWINGS
OF OTHER TRADE OF WORKS.
2. ALL LIGHTING FIXTURES INSIDE TOILET,PANTRIES,KITCHEN ANDALL
OTHER WET AREAS SHALL BE RATEDIP 44 AS MINIMUM.
3. ALL LIGHTING FIXTURES CONTROLLEDTHROUGH PDS AND
EMERGENCY LIGHT SHALL BE PROVIDEDWITH DALI BALLAST.
4. ALL LIGHTING FIXTURES SELECTION ANDLAYOUT SHALL BE
AS PER INTERIOR DESIGN; EXCEPT BACK OF THE HOUSE AREA.
5. ALL LIGHTING FIXTURES OTHER THAN BACK OF HOUSE ARE
SUBJ ECT TO INTERIOR DESIGN LIGHTING FIXTURES SCHEDULE.
6. POWER SUPPLY FOR FACADE LIGHTING IS PROVIDEDIN THE
DESIGN, THE CONTRACTOR SHALL IMPLEMENT THE FACADE
SPECIALIST'S DESIGN AS PER CLIENT'S REQUIREMENT AND
APPROVAL.
7. ALL LIGHTING POINT WHICH ARE MARKED"TO BE FINALIZEDBY
INTERIOR DESIGN" ARE ON HOLD, CONTRACTOR SHALL IMPLEMENT
THE FINAL INTERIOR LIGHTING FIXTURE SELECTION, CONTROLS
ANDFUNCTIONS.
8. FOR EXIT/DIRECTIONAL LIGHT DETAIL, REFER TO DWG NO. SG-000.
9. ALL EXIT/DIRECTIONAL LIGHTS OTHER THAN BACK OF THE HOUSE
AREA SHALL BE PROVIDEDWITH DELUXE FINISH.