Sie sind auf Seite 1von 54

GUIDED BY:

AR. NAWAB AHMAD


AR. KHALID HASSAN
AR. MANISH SAHAI
SUBMITTED BY:
SONAL
(10ARB565)
MALIHA
(10ARB567)
INDEX
1. INTRODUCTION
ABOUT THE PROJECT

2. LITERATURE STUDY


3. BYE LAWS

4. CLIMATE
MAHONEY TABLE
DESIGN INFERENCES

5. SITE STUDY

6. CASE STUDY
NRI RESIDENCY
OZONE CITY
OMAXE GRAND WOODS

7. REQUIREMENTS

8. COMPARITIVE ANALYSIS
ABOUT THE PROJECT
MAJOR REQUIREMENTS:
HOUSING AT ALIGARH, WHICH IS ONE OF THE MAJOR DISTRICT HEAD
QUARTER OF AGRA COMMISSIONAIRE. THE HOUSING HAS TO BE DONE
ON AN AREA OF 8 HECTARES THAT COMPRISES OF GROUP HOUSING,
BUILT DEVELOPMENT AND PLOTTED DEVELOPMENT.


HOUSING FOR :
HIG (HIGH INCOME GROUP)
LIG (LOW INCOME GROUP)
MIG (MIDDLE INCOME GROUP)
COMMUNITY FACILITIES, RECREATIONAL FACILITIES, PARKS AND
PLAY GROUNDS AND SERVICES.


CONSIDERATIONS:
HEAVY TRAFFIC SHOULD BE DISCOURAGED
PLANNING OF DEAD END STREETS SHOULD BE AVOIDED.
PLAN WIDER CORNER PLOTS
PRESERVE NATURAL FEATURES OF THE SITE
PLAN PLOTS FACING DESIRABLE VIEWS


STANDARS:
APPROACH ROAD ATLEAST 12M WIDE
INTERNAL ROADS ATLEAST 4.5M WIDE FOR 50M LONG ROAD AND 6M
WIDE FOR 125M LONG ROAD
SETBACK SHOULD BE 6M FROM EACH SIDE
GROUND COVERAGE :35%
FAR: 1.5
50 TREES MUST BE PLANTED PER HECTARE
IN GROUP HOUSING AND OTHER MULTI STOREYED BUILDINGS AREA
FOR PARKING AT STILT WILL BE CONSIDERED AS COVERED AREA
MAXIMUM HEIGHT OF STILT WILL BE 2.1M AND IT WILL COUNT IN FAR
MINIMUM CEILING HEIGHT SHOULD BE 2.75M
ECS FOR CARS :1
FOR TWO WHEELERS : 0.25



Requirements in this project:



AREA OF PLOT = 89929 SQM
PERCENTAGE OF COVERED ARE = 35%
POPULATION CONSIDERED = 4000
HOUSEHOLD NUMBER = 4.1-4.6
NO. OF FLATS TO BE DESIGNED = 4000/4.1=975.6= 1000 (APPROX.)
FAR = 1.5
ECS = 0.25 (for bicycle)
= 1.0 (for cars)
Services Total area (sqm)
Electrical substation 200
Generator 100
STP 120
Pump house 15
Store 100
Maintenance 200
Electrical panel room 200
Total 935

Type Coverage
Area (%)
No. of
Flats
Area per
flat
(sqft)
Area per
flat
(sqm)
Total
covered
area
(sqm)
No. of
storey
Area
covered
by one
floor
(sqm)
No. of
towers
LIG 35 250 900 83 20750 G+3 5187.5 5
EWS 35 100 600 56 5600 G+3 1400 6
MIG 55 550 1200 112 61600 G+6 8800 3
HIG 10 100 1600 149 14900 G+3 375 2

THE NEED FOR NEW HOUSING UNDER CONTINUING URBANIZATION
INDICATES THAT HOUSING MARKET WILL BE DEVOTED TO
MULTIFAMILY TYPES OF HOUSING OR APARTMENTS. THIS TREND
CONTAINS A CHALLENGE TO THE ARCHITECT TO DO MORE THAN
MERELY MEET A STATISTICAL DEMAND. HE MUST RATHER
ADDRESS, IDENTIFY, AND SOLVE THE PROBLEMS OF MULTIFAMILY
BUILDING TYPES AS AN ATTRACTIVE ALTERNATIVE TO
FREESTANDING SINGLE FAMILY BUILDINGS.

AT THE SAME TIME, INDIAS POPULATION HAS CROSSED A MARK OF
100 CRORES AND ESTIMATION SAYS THAT BY THE YEAR 2021, 350
MILLION PEOPLE WILL BE ADDED WITH FURTHER CONCENTRATION
OF POPULATION IN URBAN CENTER UP TO 12 PERCENT.
ACCORDING TO CENSUS OF 2001, INDIA HAD TOTAL RESIDENTIAL
HOUSING STOCK OF 187 MILLION WITH ONLY 51% PERMANENT
DWELLING UNITS. FURTHERMORE, OUT OF THIS HOUSING STOCK
MOSTLY HAVE NO SANITATION FACILITY, ELECTRICITY AND
DRAINAGE FACILITY. ACCORDING TO AN ESTIMATE INDIA HAD A
CHRONIC SHORTAGE OF 21.23 MILLION DWELLING UNITS, OUT OF
WHICH 36% ARE REQUIRED IN URBAN CENTERS. HOWEVER, IT
SEEMS TO BE DIFFICULT FOR PUBLIC SECTOR AGENCIES TO
ACCELERATE RATE OF HOUSING PROVISION LOOKING AT LIMITED
FINANCIAL RESOURCES. SO WORKING ON THIS HOUSING PROJECT
WOULD POSE A CHALLENGE IN UNDERSTANDING THE PROBLEM
AND THE ANALYSIS OF IT.

THE URBAN GROUP HOUSING BASICALLY OUTLINES THE NEED TO
OVERCOME THE SHORTAGE OF HOUSING DUE TO DENSE
POPULATION GROWTH RATE IN URBAN CITIES. THUS THE NEED OF
PROVIDING CHEAP EASY AFFORDABLE HOUSING WITH AMENITIES
CATERING TO ALL THE INCOME GROUPS.

THE LIG,HIG,MIG ARE DISTRIBUTED ACROSS THE AREA IN
PERCENTAGES ARE CONNECTED ACCORDINGLY TO THE
COMMERCIAL CENTERS , TRANSPORTATION , HOSPITALS AND
SCHOOLS

THE PERCENTAGES OF DISTRIBUTION OF THE INCOME GROUPS IS
DONE ACCORDING TO THE CURRENT DEVELOPMENT RATE OF THE
CITY CONCERNED

INTRODUCTION
AFFORDABLE HOUSING CAN BE DEFINED USING THREE KEY
PARAMETERS VIZ. INCOME LEVEL, SIZE OF DWELLING UNIT AND
AFFORDABILITY. WHILE THE FIRST TWO PARAMETERS ARE
INDEPENDENT OF EACH OTHER, THE THIRD PARAMETER IS
CORRELATED INCOME. HOUSING COSTS HERE INCLUDE TAXES
AND INSURANCE FOR OWNERS, AND UTILITY COSTS

DEFINING AFFORDABLE HOUSING IN INDIA IS A DIFFICULT TASK
GIVEN THAT AT EVERY SQUARE KILOMETER OF THE COUNTRY, THE
DYNAMICS OF THE MARKET ARE DIFFERENT. THEREFORE
BROADLY DEFINED AFFORDABLE HOUSING IN INDIA FOR TIER I, II
AND III CITIES BASED ON THREE KEY PARAMETERS
TWO ISSUES THAT DELINEATE TRADITIONAL INDIAN LIVING ARE,
FIRST A CLIMATIC NEED FOR LIVING OUTDOORS, AND SECOND A
FAMILYS SOCIAL NEED TO INTERACT WITH THE SURROUNDING.
MOST PRIVATE MULTI-STORIED HOUSING TODAY FAILS TO
ADDRESS THESE TWO INITIAL ISSUES OF TRADITIONAL LIVING.
SINCE, THE COURTYARD AND TERRACES ADDRESS THESE
ISSUES THEY OFTEN FORM AN INTEGRAL PART OF A
TRADITIONAL SETTLEMENT.
I
N
T
R
O
D
U
C
T
I
O
N
LITERATURE STUDY
HOUSING IS PERMANENT SHELTER FOR HUMAN HABITATION. BECAUSE
SHELTER IS NECESSARY TO EVERYONE, THE PROBLEM OF PROVIDING
ADEQUATE HOUSING HAS LONG BEEN A CONCERN, NOT ONLY OF
INDIVIDUALS BUT OF GOVERNMENTS AS WELL. THUS, THE HISTORY OF
HOUSING IS INSEPARABLE FROM THE SOCIAL, ECONOMIC, AND POLITICAL
DEVELOPMENT OF HUMANKIND.
A NEIGHBORHOOD IS A GEOGRAPHICALLY
LOCALIZED COMMUNITY WITHIN A LARGER CITY, TOWN OR SUBURB.
IT IS SIMPLY A PHYSICAL ENVIRONMENT IN WHICH A MOTHER KNOWS
THAT HER CHILD WILL HAVE NO TRAFFIC STREETS TO CROSS ON HIS WAY
TO SCHOOL- A SCHOOL THAT IS WITHIN EASY WALKING DISTANCE FROM
HOME, AN ENVIRONMENT IN WHICH HOUSEWIFE MAY HAVE EASY WALK
TO SHOPPING CENTRE, AN EMPLOYED PERSONS MAY FIND CONVENIENT
TRANSPORTATION TO AND FROM WORK, CHILDREN MAY PLAY IN SAFETY
WITH THEIR FRIENDS. WE CAN SAY IT REPRESENTS A UNIT OF
POPULATION WITH BASIC COMMON NEEDS FOR EDUCATIONAL,
RECREATIONAL AND OTHER SERVICE FACILITIES. THIS CONCEPT WAS
DEFINED BY CLARENCE A. PERRY.
NEIGHBOURHOOD CONCEPT-
PRINCIPLES OF
NEIGHBOURHOOD THEORY:

UNIT OF URBAN PLANNING
STREET SYSTEM
FACILITIES
POPULATION
SECTOR
SIZE AND DENSITY
NEIGHBORHOOD WALKWAYS
PROTECTIVE STRIPS
Single Detached:
HOME DESIGN
UNIT LAYOUT CAN BE FLEXIBLE AT LOWER DENSITIES.
STRONG INDIVIDUAL IDENTITY AND PERSONALIZATION.
THERE IS A RICHLY DEVELOPED DESIGN VOCABULARY AND
MUCH VARIETY FOR THIS TYPE.
TREND TOWARD LARGER UNITS CONSUMES MORE MATERIAL
AND ENERGY.
SITE DESIGN
YARD CAN STRONGLY EXPRESS IDENTITY OF RESIDENTS.
CLEAR MARKING OF PUBLIC AND PRIVATE SPACE IS POSSIBLE.
FEWER NEIGHBORS MEANS FEWER OVERLOOKERS BUT ALSO
FEWER WATCHERS WHICH MAY NEGATIVELY AFFECT INFORMAL
SURVEILLANCE IN THE NEIGHBORHOOD.
PARKING IS FLEXIBLE EVEN AT HIGHER DENSITIES.
INCREASING LAWN SIZES CAN HAVE A DISPROPORTIONATELY
NEGATIVE IMPACT ON WATER QUALITY AND NATURAL HABITAT.

NEIGHBORHOOD AMENITIES
NUMBER AND TYPE OF RETAIL AND PUBLIC AMENITIES WITHIN
WALKING DISTANCE CAN BE LIMITED DUE TO LOWER NUMBERS OF
RESIDENTS.
TRANSIT ACCESS IS OFTEN POOR.
REGIONAL ENVIRONMENTAL IMPACTS AND TRANSPORTATION
COSTS AT LOWER DENSITIES CAN BE GREAT DUE TO VEHICLE
MILES TRAVELED.
BIG HOUSE/MULTIPLEX:
HOME DESIGN
UNITS CAN BE SINGLE- OR MULTI-LEVEL.
UNIT ACCESS CAN BE PRIVATE AND EXTERIOR; SHARED ENTRANCE
PRESENTS PRIVACY AND MAINTENANCE CHALLENGES.
OVERLOOKS AND REAR YARD DISTANCES HAVE SIGNIFICANT IMPACT
ON PRIVACY AND FUNCTION OF OUTDOOR SPACES.
ACCESS TO SUNLIGHT AND AIR IS AFFECTED BY THE NUMBER OF
EXTERIOR WALLS WITH WINDOWS AND THE DIRECTION THEY FACE.
SITE LAYOUT VERY IMPORTANT AND VARIES BY ARRANGEMENT OF
UNITS IN BUILDING.
PARKING CAN BE CHALLENGING, BUT OPPORTUNITIES EXIST FOR
BOTH ON- AND OFF-STREET IN A VARIETY OF FORMS.
NEIGHBORHOOD AMENITIES
POTENTIAL FOR INCREASED RETAIL AND SERVICES DUE TO
INCREASED DENSITY.
TRANSPORTATION OPTIONS GENERALLY GREATER.
NEARBY OPEN SPACES ARE
NEEDED FOR SOME
OUTDOOR ACTIVITIES.
L
I
T
E
R
A
T
U
R
E

S
T
U
D
Y

HOUSING TYPES
SIDE ATTACHED:
HOME DESIGN
INDIVIDUAL FRONT DOORS IN A COMPACT FORM ALLOW FOR MORE
INFORMAL SURVEILLANCE.
PERSONALIZATION IS CRITICAL IN DISTINGUISHING ONE UNIT
FROM THE NEXT IN WHAT CAN BE A RATHER UNIFORM
STREETSCAPE.
MANY VARIATIONS APPEAR ACROSS THE COUNTRY.
.
.
SITE DESIGN
OVERLOOKS AND REAR YARD DISTANCES HAVE SIGNIFICANT IMPACT ON
OUTDOOR PRIVACY.
SIDE-TO-SIDE LAYOUT ACHIEVES INTENSITY BUT ACCESS TO OUTDOOR
SPACE AND NATURAL LIGHT REQUIRE CAREFUL DESIGN.
WIDE VARIETY OF SITE LAYOUTS ARE POSSIBLE TO SHAPE OUTDOOR
SPACES SUCH AS STREET CORRIDORS.
PARKING CAN BE ON-STREET, OFF-STREET, UNDER UNITS.
PRIVATE AND SHARED OUTDOOR SPACE CAN TAKE A VARIETY OF
SHAPESDESPITE LIMITED SIZEAND SHOULD ACCOMMODATE A
VARIETY OF USES
HOME DESIGN
PRIVATE AND SHARED
OUTDOOR ACTIVITIES
SHOULD BE
ACCOMMODATED WITH
ELEMENTS SUCH AS
STOOPS, BALCONIES,
TERRACES, AND
PLAYGROUNDS.
Stacked Row house:
INCREASE IN DENSITY BEGS MORE ATTENTION TO PRIVACY AND
TERRITORY, ESPECIALLY FOR SIGHTLINES AND PRIVATE OUTDOOR
SPACE.
PERSONALIZATION IS CRITICAL IN DISTINGUISHING ONE UNIT FROM
THE NEXT IN WHAT CAN BE A RATHER UNIFORM STREETSCAPE.
DUPLEX/ TRIPLEX:
HOME DESIGN
EXTERIOR ENTRIES CAN BE SHARED OR SEPARATE, BUT CAREFUL
ATTENTION TO PRIVACY, TERRITORY, AND MAINTENANCE IS NEEDED.
PERSONALIZATION IS POSSIBLE AND DESIRABLE, ESPECIALLY AT
ENTRIES.
ADAPTABLE TO MANY DIFFERENT KINDS OF SITES.
EXTERIOR SIZE AND MASSING USUALLY APPEARS VERY SIMILAR TO
A SINGLE DETACHED UNIT
SITE DESIGN
TERRITORY AND MAINTENANCE IMPORTANT IN YARD; PROVIDE
PRIVATE OUTDOOR SPACE FOR EACH UNIT.
OVERLOOKS AND BACK-TO-BACK DISTANCES HAVE SIGNIFICANT
IMPACT ON PRIVACY OF OUTDOOR SPACES.
RELATIVELY HIGH RATIO OF IMPERVIOUS SURFACE TO UNIT.
UNITS SERVED BY BOTH STREET AND ALLEY SEEM TO HAVE AN
ADVANTAGE.
PARKING IS FLEXIBLE, WITH ON- AND OFF-STREET BOTH POSSIBLE.

NEIGHBORHOOD AMENITIES
TYPE CAN INCREASE POPULATION DENSITY WHILE MAINTAINING A
SINGLE DETACHED CHARACTER.
NEARBY FACILITIES AND TRANSIT ARE LIKELY TO BE GREATER THAN
SINGLE DETACHED SITUATIONS.
CAN PROVIDE OPTIONS FOR HOUSING CHOICE AND AFFORDABILITY
CURRENTLY UNAVAILABLE IN MANY AREAS.
SMALL APARTMENT:
Home design
CENTRAL HALL OR STAIR ACCESSIBLE FROM THE STREET.
MUST HAVE SOME SHARED ACCESS TO UNITS - SHARING AMONG 6-
10 UNITS IS RECOMMENDED.
AT LEAST TWO SIDES WITH WINDOWS RESULTS IN COMFORTABLE
LIGHT AND AIR QUALITY OF INDOOR SPACES.
SOME FIRST FLOOR UNITS ACCESSIBLE FROM GROUND, AFFECTING
OVERLOOKS AND SECURITY.
UNIT IDENTITY AND PERSONALIZATION POSSIBLE IN OUTDOOR
SPACE, UNIT FRONT DOOR (OR WINDOWS), INSTEAD OF FRONT DOOR
TO BUILDING.
SITE DESIGN
PARKING IS A CHALLENGE DUE TO HIGH LOT COVERAGE.
GROUND IS TYPICALLY SHARED TO SOME DEGREE.
MOST OFTEN FOUND ON URBAN PARCELS, SO STREET FACADE
AND ENTRY SEQUENCE DESIGN IS CRITICAL.
CLEAR MARKING OF PRIVATE AND SHARED TERRITORY IS
IMPORTANT.

NEIGHBORHOOD AMENITIES
LOCAL STORES ARE OFTEN WITHIN WALKING DISTANCE.
PEDESTRIAN ACCOMMODATIONS ARE CRITICAL.
TRANSIT ACCESS IS USUALLY VERY GOOD.
LOW RISE APARTMENT:
HOME DESIGN
UNITS USUALLY ACCESSED BY INTERIOR HALLWAY.
VIEWS AND OVERLOOKS AN ISSUE FOR LOWEST FLOORS.
INDIVIDUAL UNIT IDENTITY AND PERSONALIZATION IS FOCUSED ON
PRIVATE OUTDOOR SPACE OR, INTERIOR UNIT ENTRANCE INSTEAD OF
OUTSIDE FRONT DOOR.
IN RENTAL UNITS, CAREFUL DESIGN CAN ENCOURAGE SENSE OF
OWNERSHIP AND TERRITORY, LEADING TO BETTER MAINTENANCE.
INTERIOR LAYOUTS CRITICAL TO LIVABILITY.
SITE DESIGN
PARKING REQUIRES A CLEAR STRATEGYUSUALLY OFF-STREET AND
INCREASINGLY UNDERGROUND.
FLEXIBLE FORM CAN RESPOND TO NATURAL OR BUILT FEATURES, BUT
OFTEN SITED TO PRODUCE MAXIMUM UNIT COUNT.
PRIVATE OUTDOOR SPACE AVAILABLE ON BALCONIES OR PATIOS, BUT
MOST OUTDOOR SPACE IS SHARED BY ALL RESIDENTS.

NEIGHBORHOOD AMENITIES
POPULATION IN DENSER EXAMPLES CAN SUPPORT LOCAL, WALK ABLE
RETAIL.
TRANSIT ACCESS IS OFTEN VERY GOOD COMPARED TO THE
SURROUNDING AREA.
Mid Rise Apartment:
HOME DESIGN
BUILDING BULK IS LARGE BUT CAN BE SHAPED TO RESPOND TO
SURROUNDINGS.
INTERIOR UNIT LAYOUT CRITICAL FOR LIVABILITY.
GROUND IS USUALLY SHARED. PRIVATE OUTDOOR SPACE
POSSIBILITIES LIMITED TO BALCONY, ROOFTOP.
ELEVATORS ARE REQUIRED.
SECURITY AT GROUND CAN BE CHALLENGING WITH HIGH NUMBER
OF RESIDENTS AND RELATIVELY FEW AT A LEVEL WHERE THEY CAN
ADEQUATELY OBSERVE.
NEEDS CLEAR DEFINITION OF PUBLIC AND PRIVATE SPACE
SITE DESIGN
PARKING IS STRUCTURED IN DENSER LOCATIONS, ABOVE OR
BELOW GRADE.
GREAT ACCESS TO STREET, BUT CAREFUL DESIGN NEEDED TO
MAINTAIN PRIVACY.
SITE PLANNING HAS POTENTIAL TO AFFECT THE ECOLOGICAL
CHARACTER OF THE SITE.

NEIGHBORHOOD AMENITIES
CAN INCORPORATE A VARIETY OF UNIT SIZES AND AFFORD ABILITIES
SEAMLESSLY.
DENSITY CAN SUPPORT FREQUENT TRANSIT SERVICE AND LOCAL
SHOPPING, AND BE NEAR REGIONAL AMENITIES SUCH AS
DOWNTOWNS AND RECREATION.
WELL DESIGNED PUBLIC OUTDOOR SPACES SUCH AS SIDEWALKS,
PARKS, AND TRAILS ARE CRUCIAL.
Apartment over Commercial:
HOME DESIGN
INTERIOR UNIT LAYOUT IS CRITICAL FOR LIVABILITY.
SHARED ENTRIES, HALLWAYS, ELEVATORS, AND STAIRS REQUIRE
CAREFUL DESIGN FOR SAFETY AND SOCIABILITY.
UNIT INDIVIDUALIZATION OCCURS MOSTLY AT INTERIOR UNIT
ENTRANCE.
WIDE VARIETY OF OUTDOOR SPACES IF ROW HOUSES ARE
BELOW, MUCH NARROWER RANGE IF COMMERCIAL.
DISTINCT BUILDING USES REQUIRE CAREFUL DESIGN TO
SEPARATE OR INTEGRATE PEDESTRIAN ACCESS, PARKING,
DELIVERIES, AND TRASH PICK-UP.
SITE DESIGN
PARKING NEEDS CAREFUL ATTENTION TO BALANCE DAY AND
EVENING USES.
MAY EXIST IN STREET-FRONTAGE SITUATION OR, MORE RARELY,
WALK-UP OPTIONS.

NEIGHBORHOOD AMENITIES
HIGH DENSITY ALLOWS FOR GOOD ACCESS TO SERVICES AND
FACILITIES, INCLUDING TRANSPORTATION, RECREATION,
EDUCATION, SHOPPING, ETC.
AN ACTIVE PEDESTRIAN ENVIRONMENT AND SHARED PARKS ARE
REQUIRED FOR LIVABILITY.
High Rise Apartment
HOME DESIGN
PRIVATE OUTDOOR SPACE POSSIBLE ON BALCONIES OR
PRIVATE ROOF GARDENS; SHARED OUTDOOR SPACE ON ROOF
OR GROUND AROUND BUILDING.
UNIT PRIVACY GENERALLY HIGH.
SHARED ENTRIES, HALLWAYS, ELEVATORS, AND STAIRS
REQUIRE CAREFUL DESIGN FOR SOCIABILITY.
PERSONALIZATION OF UNITS IS DIFFICULT EXCEPT AT INTERIOR
UNIT ENTRIES.
IMAGE RELIES ON OVERALL BUILDING CHARACTER AND FORM.
SITE DESIGN
STRONG POSSIBILITY OF PRESERVING OPEN SPACE, AT THE
EXPENSE OF LARGE SHADOWS, INTERRUPTED VIEWS, AND EXTREME
SCALE SHIFT FROM LOWER SURROUNDING DENSITIES.
PARKING MUST BE STRUCTURED, PROBABLY UNDERGROUND.
PEDESTRIAN AMENITIES ARE CRITICAL.

NEIGHBORHOOD AMENITIES
TRANSIT AND COMMERCIAL ACCESS GENERALLY HIGH, UNLESS
TOWER IN THE GREEN SITE DESIGN SEPARATES THE BUILDING
FROM OTHER FACILITIES.
CAN BE IN VERY URBAN LOCATIONS.
RADBURN LAYOUT
INSPIRED BY GARDEN CITY CONCEPT. IT IS LOCATED IN NEW
JERSEY, WHICH IS WITHIN COMMUTING DISTANCE FROM NEW
YORK.
THIS LAYOUT WAS PLANNED BY HENRY WRIGHT AND CLARENCE
STEIN , CONCEPT OF SUPER BLOCK OF 30 TO 50 ACRES WAS
INTRODUCED.
IN THIS LAYOUT PEDESTRIAN AND VEHICULAR TRAFFIC ARE
SEGREGATED .SINGLE FAMILY DWELLINGS WERE GROUPED
AROUND CUL-DE-SAC ROADS. KITCHENS AND GARAGES FACED
THE REAR ROAD AND LIVING ROOMS FACED THE FRONT GARDEN.
ACCESS TO THE DWELLING BY CAR IS FROM REAR COURTYARDS,
WHERE GARAGES ARE LOCATED .
THE PEDESTRIAN ENTRY IS FROM FRONT SIDE.
T HAS ALLOCATED SPACE FOR INDUSTRY , SHOPPING AND
APARTMENTS BUT GREENBELT WAS NOT INCORPORATED.
IT IS A WELL LAID OUT SAFE AND QUITE AREA
FOR THE RESIDENTS AND BECAME A MODEL FOR LATER LAYOUT
PLANNING OF RESIDENTIAL AREAS.

A DIAGRAM SHOWING THE STREET NETWORK STRUCTURE OF
RADBURN AND ITS NESTED HIERARCHY. SEPARATE PEDESTRIAN
PATHS RUN THROUGH THE GREEN SPACES BETWEEN THE CULS-DE-
SAC AND THROUGH THE CENTRAL GREEN SPINE.
ELECTRICAL SERVICE
BASED ON THE ESTIMATED REQUIREMENT OF WATER SUPPLY , THE
CONSUMPTION WORK OUT TO BE 2 KW PER HOUSE HOLD AT CITY
LEVEL. THE PROVISION OF ONE ELECTRIC SUBSTATION OF 11KV FOR
POPULATION OF 15000 IS RECOMMENDED AS A GENERAL STANDARD .

DRAINAGE
THE DRAINAGE SYSTEM OF ANY CITY IS GOVERNED BY ITS NATURAL
DRAINAGE COURSE AND TOPOGRAPHY BESIDES ON ITS IMPACT ON
REGION LEVEL OF DEVELOPMENT , ITS CLIMATIC AND
HYDROLOGICAL CONSIDERATION THE DISCHARGE IS CALCULATED
THAT GUIDES THE CONSIDERATION OF PROVISION OF ADDITIONAL
DRAIN AND UP GRADATION OF EXISTING ONE.

WATER SUPPLY
FOR TOWN HAVING POPULATION LESS THAN 50000(SMALL TOWN)
ABSOLUTE MIN WATER SUPPLY FOR DOMESTIC PURPOSE IS 70 LPCD
BUT 100 LPCD IS DESIRABLE.

FIRE FIGHTING
THE FIRE SERVICE OF SMALL OR MEDIUM SIZE TOWN SHALL BE
PROVIDED TAKING CONSIDERATION OF NEEDS OF SURROUNDING
VILLAGES.
PARKING
PARKING SPACE REQUIREMENT FOR CAR 3M X 6M (FOR INDIVIDUAL
PARKING) AND 2.5M X 5M(FOR COMMUNITY PARKING).
19
LOCATION :
SITE IS LOCATED NEAR ACN COLLEGE OF ENGINEERING AND
TECHNOLOGY ,NATIONAL HIGHWAY 93.

ACCESS :
BY NATIONAL HIGHWAY 93

DISTANCE FROM :
RAILWAY STATION : 17KM
HOSPITAL: 1.5KM
SCHOOL: 2KM

SITE SURROUNDING :
NORTH, NORTH-WEST, NORTH-EAST - AGRICULTURAL LAND
EAST ACN COLLEGE
SOUTH WEST NATIONAL HIGHWAY (ENTRANCE TO THE SITE)
POLICE LINE ALIGARH AT THE LEFT SIDE NEAR THE ENTRANCE

SITE
SOIL CONDITION :
SILTY CLAY

SIESMIC ZONE :
ZONE 4

TO BE USED FOR :
GROUP HOUSING

PRESENTLY USED AS :
A GRAZING LAND + AGRICULTURAL

SITE AREA : 22 ACRES
DEVELOPMENT AUTHORITY :
THE PROPOSED SITE COMES UNDER THE JURISDICTION OF THE
ALIGARH DEVELOPMENT AUTHORITY
FOUNDATION :
ISOLATED FOUNDATION
SERVICES :
ELECTRICITY LINES ARE GOING THROUGH THE SITE.
TRANSFORMER ON THE SITE.
SEWAGE FACILITY IS PRESENT THOUGH NOT EFFICIENT.
THE SITE IS 1OOMM BELOW THE ROAD LEVEL.
TOPOGRAPHY:
TREES ARE PLANTED ON THE FRONT SIDE OF THE SITE .
THE LAND IS MOSTLY EVEN EXCEPT FOR A FEW PLACES .



20
BUILDING BYE LAWS AND
REGULATIONS
Emergence of building bye-laws is a phenomenon that rules parallel to human civilization and its
progress. Initially, the necessity of bye-laws was felt due to safety aspect of buildings.
These building bye-laws are considered to be useful tool to control building activities and are
necessary to be forward. A free for all situations is certainly not desirable since human tendency to
take advantage those prevail.
BYE-LAWS FOR GROUP HOUSING
These are double or multi-storied
Minimum area = 1000 sq.m
ROADS:
Approach road leading to the proposed area for housing (4 floors), minimum width = 9m.
For more than 4 storied building, or site more than 4000 sq.m, minimum width = 12m.
For internal roads minimum width = 4.5m & length = 50m,
for length = 125m, the minimum width should be = 6m & for length = 250m the width
should be = 9m.
Length (m) Min. width (m)
50 4.5
Up to 125 6.0
Up to 250 9.0
251 400 12.0
401 600 18.0
More than 600 24.0
Road adjacent to park or open space can be 7.5 m wide instead of 9m.
FOR LIG & EWS
Type of roads length (m) min. width (m)

Motor able roads 6.0
Walk able roads
One side unit & other 50 3.0
side open space
Both side units 80 4.5
DRAINAGE SYSTEM: As part of roads with proper slope or gradient.
21
PARKS, OPEN SPACES & LANDSCAPING

Open spaces to be left = 0.1 hectare for 1000 persons.
Trees @ 50 per hectare.
GROUND COVERAGE = 35%
F.A.R = 1.5
MAX. DWELLING UNITS = 150 PER HECTARE
MAX. AREA OF ONE = 125 SQ.M
DWELLING UNIT
CONVINIENT SHOPS@ 5 PER 1000 PERSONS
AREA OF COMMON FACILITIES = 10% OF THE LAND AREA TO A MAX. OF 400 SQ.M.
BYE LAWS FOR DWELLING UNIT
A). LIVING ROOM
Min. area = 9.5 sq.m, min. width = 2.4m
Min. ceiling height from floor = 2.75 m
Min. floor to duct or false ceiling height = 2.4m
Min. height of floor to bottom of beam = 2.45m
B). KITCHEN
Min. area = 5 sq.m, min. width = 1.8m
If area of flat less than or equal to 60 sq.m then
Min. area =3.5 sq.m, min. width = 1.5m
Min. ceiling ht. from floor = 2.75m
Min. area = 4.5 sq.m (if separate store)
Min. area = 9.5 sq.m (if extended for dining) min. width= 1.8m

C). BATHROOM & TOILET (W.C)
Min. area of bath = 1.5 sq.m, min. width 1.0m
Min. area of w.c = 1.1 sq.m, min. width = 0.9m, min. ht. = 2.2m
Min. area of bath with w.c = 2.8 sq.m, min. width = 1.2m

D) LIGHT
1). LIVING ROOM
Provision of windows, ventilators, opening towards an O.T.S or verandah (max. width = 3.0 m).
Open area in the room (excluding doors) should be min. 10% of the floor area of the room.
Any part of the room whose distance is more than 7.5 m will not be treated lit or ventilated.
If residential room is being lit by internal open spaces then minimum area of open space (for building
upto 10m) = 7.5sq.m and minimum width = 3m and area = 1.5 times the length of the highest
adjoining wall.
22
B
U
I
L
D
I
N
G

B
Y
E
L
A
W
S

2). KITCHEN
Minimum 1 sq.m or 10% of floor area of kitchen should have a window.

3). BATHROOM & TOILET (W.C)
For ventilation, ventilators should have open area of minimum width = 3m for areas having
less width shaft should be provided whose sizes are as follows:
Height of building Area of min. Width of shaft
(m) (sq.m) (m)
Up to 6 1.2 0.9
Up to 12 2.8 1.2
Up to 18 4.0 1.5
Up to 24 5.4 1.8
Up to 30 8.0 2.4
More than 30 m 9.0 3.0
E) STAIRS:
For group housing min. width=1.2m
Min tread=25cm
Min riser=19cm
Max. Number of steps in one flight-12
Min height of hand rail from middle of tread=85
BOUNDARY WALL:
Max. Height of front wall=1.65m (above the level at the center of the road.
Wall of rear yard=2m or a max. of 3m.above the level at the Centre of the service road.

G) BASEMENT:
Constructed ensuring the structural safety of the adjacent building or 2m away from the adjoining
building.
Min. height of each part from floor to ceiling=2.4m
Walking distance should not be more than 15m & proper exits should be provided.
No kitchen, bathroom or toilet (w.c) to be provided in basement.

H) PARKING SPACE:
13.75SQMX1.25 (ECS/100SQM) 142.85(TOTAL AREA) =245.23SQM
For buildings less than 15m, 50% area can be used for parking on if an offset of 3.6m will be left
free from parking or loading or unloading activity.
23
SETBACK FOR GROUP HOUSING:
LANDUSE FOR THE GROUP HOSING PROJECT
24
Mahoney table 1 First part
Rain and wind
TOTAL: 721.4mm
Mahoney table 1 SECOND part
Relative Humidity: %

MAHONEY TABLE
25
C
L
I
M
A
T
E
A
N
A
L
Y
S
I
S
MAHONEY TABLE 2- FIRST PART
MAHONEY TABLE 2- SECOND PART
Mahoney table 3
INDICATOR TOTALS FROM TABLE 2

LAYOUT
SPACING
26
27
MAHONEY TABLE 4
INDICATOR TOTALS FROM
TABLE2
28
GEOGRAPHICAL LOCATION :
ALIGARH LIES AT LATITUDE 2730N AND LONGITUDE 7940

ALTITUDE :
300M

CLIMATE :
COMPOSITE CLIMATE
THIS TYPE OF CLIMATE IS NEITHER CONSISTENTLY HOT AND DRY NOR
WARM AND HUMID

CHARACTERISTICS CHANGES FROM SEASON TO SEASON
ALTERNATING BETWEEN LONG HOT DRY PERIODS TO SHORTER
PERIODS OF CONCENTRATED RAINFALL AND HIGH HUMIDITY
TWO SEASONS OCCUR NORMALLY
~ 2/3 OF THE YEAR HOT-DRY OR COOL DRY
~ 1/3 OF THE YEAR WARM HUMID
HOT SUMMERS AND COLD WINTERS
WARM HUMID JUNE TO OCTOBER
HOT DRY APRIL TO JUNE
COLD DRY NOVEMBER TO FEBRUARY

29
HUMIDITY :
ALL THE YEAR ROUND R-H IS LOW 20 55%
DURING MONSOON 55-95%

PRECIPITATION :
ANNUAL RAINFALL VARIES FROM 500- 1000MM.

SKY CONDTION :
HEAVILY OVERCAST AND DULL DURING MONSOON AND CLEAR
WITH DARK BLUE COLOUR IN DRY SEASON.

SOLAR RADIATION :
RADIATIONS ARE STRONG WITH A HIGH DIFFUSE COMPONENT DUE
TO THIN CLOUDS AND SUSPENDED MOISTURE FOR HOT AND DRY
PERIOD OF THE SEASON.
WHEREAS DURING WARM HUMID PERIOD , RADIATIONS EVEN
THOUGH BEING REFLECTED BY CLOUDS REACHES GROUND LEVEL
AND CAUSES GLARE .
THESE ARE THE POINTS TO BE CONSIDERED FOR CLIMATIC
DESIGN AT ALIGARH :-

(A) FORM AND PLANNING :
COURTYARD TYPE BUILDINGS ARE VERY SUITABLE , SHOULD
BE GROUPED IN SUCH A WAY SO AS TO TAKE ADVANTAGE OF
PREVAILING BREEZE DURING THE PERIOD WHEN MOVEMENT IS
NECESSARY
A MODERATELY LOW RISE DEVELOPMENT WITH VARIATION IN
HEIGHT OF THE BUILDING SUITABLE FOR THESE CLIMATES ,
WHICH WILL ENSURE PROTECTION OF OUTDOOR SPACES
MUTUAL SHADING OF EXTERNAL WALLS , SHELTER FROM WIND
IN COLD SEASON , SHELTER FROM DUST AND REDUCTION OF
SURFACES EXPOSED TO SOLAR RADIATION.
ROOFS SHALL HAVE LOW TRANSMITTANCE VALUE AND GOOD
THERMAL CAPACITY . THERMAL LOADING REDUCED DURING
HOT-DRY AND COLD SEASONS
B) EXTERNAL SPACES :
LARGE PROJECTION EAVES AND WIDE CORRIDORS ARE
NEEDED FOR WARM HUMID SEASON AS OUT DOOR AREAS ,
TO REDUCE SKY GLARE , KEEP OUT OF THE RAIN AND
PROVIDE SHADE.
LOUVERS NEEDED
VEGETATION CAN ALSO HELP IN STOPING SUN RAYS AND
DUSTY WINDS
A COURTYARD IN THE MOST PLEASANT OUTDOOR SPACE
FOR MOST OF THE YEAR AS IT EXCLUDES THE WINDS AND
TRAPS THE SUN . BUT SHOULD BE ALLOWED IN SUCH A
MANNER THAT IT ALLOWS SUN RADIATION DURING WINTERS.
C) ROOFS AND WALLS :
ROOFS AND EXTERNAL WALLS SHOULD BE THEREFORE
CONSTRUCTED OF SOLID MASONRY OR CONCRETE TO HAVE
TIME LAG OF 9-12 HOURS IN HEAT TRANSMISSION , SINCE
HEAT CONTROL IS NECESSARY IN BOTH THE SEASONS
.
(E) OPENINGS :
NORTH AND SOUTH WALLS PREFFERED ACCORDING TO GLARE
PREVENTION
NORTH WEST WINDS PREVAILS SO OPENING SHOULD BE THERE
NEVER GIVE BALCONY OR WINDOWS IN SOUTH WEST
DIRECTION AS HOT SUN COMES IN
CROSS VENTILATION IS REQUIRED , SO VENTILATORS
NECESSARY
SIZE OF OPENINGS ( 25 40 ) %
( D ) SURFACE TREATMENT :
THE PREVENTION OF HEAT ENTERING THROUGH OUTER
SURFACES OF THE WALLS AND ROOF IS FUNDAMENTAL RULE.
SURFACED EXPOSED TO THE SUN DURING THE HOT AND
WARM SEASONS SHOULD BE LIGHT COLOURED OR SHINY
POLISHED METAL .
DURING WINTERS OPPOSITE IS THE CASE . THEREFORE
COMBINATION IS PREFERRED WITH DOMINANCE OF
REFLECTING SURFACE
IT IS BENEFICIAL TO OBTAIN SOME SUNLIGHT IN THE DWELLING DURING
THE DAY .A DWELLING THAT IS FACING DIRECTLY NORTH AND RECEIVING
NO SUNLIGHT TENDS TO BE A COOL OR AIRY DWELLING.
BEDROOMS
SUNLIGHT STREAMING INTO THE BEDROOM UPON WAKING UP IN THE
MORNING IS A PLEASANT FEELING.
WEST EXPOSURE SHOULD BE AVOIDED BECAUSE THE WEST SUN DURING
THE SUMMER MONTHS IS STRONG AND HEATS UPS THE ROOM DURING THE
LATE AFTERNOON AND EARLY EVENING.
LIVING ROOM
THE LIVING ROOM SHOULD HAVE A SOUTHERLY EXPOSURE.IN HOT
CLIMATES,
A PROPERLY DESIGNED OVERHANG WILL PREVENT DIRECT SUNLIGHT
FROM ENTERING THE ROOM.IN WINTER TIME THE LOW ANGLE OF THE SUN
WILL ALLOW SUNLIGHT TO PENETRATE THE DEPTH OF THE ROOM.
KITCHEN
NORTH IS GENERALLY CONSIDERED TO BE THE BEST ORIENTATION FOR
KITCHENS AND LAUNDRY AREAS BECAUSE IT PROVIDED AN EVEN ,NO
GLARE LIGHT,
LOCATION: PARICHOWK EXPRESSWAY, GREATER NOIDA

ACCESS: NOIDA-GREATER NOIDA EXPRESSWAY

ZONE: ZONE4

SITE SURROUNDING: EXPO MART, ANSAL PLAZA, JP GREEN GOLF
COURSE, KNOWLEDGE PARK, GOLF LINK, NRI CITY SOME OF THE
BEST ACADEMIC INSTITUTIONS LIKE GAUTAMA BHUDH UNIVERSITY,
IEC, GALGOTIA, GNIT, IIT ROORKEE GREATER NOIDA ARE ALREADY
ESTABLISHED NEARBY THIS RESIDENCY.
DND EXPRESSWAY: 25MINS FROM NEW FRIENDS COLONY. 35MIN
FROM SOUTH EXTENSION. 50MIN FROM CONNAUGHT
PLACE

TOTAL FLATS-
CASE STUDY 1
NRI RESIDENCY
TYPES OF HOUSES: TYPE A (220SQFT/205SQM)
TYPE B (1490SQFT/139SQM)
TYPE C (1215SQFT/113SQM)
TYPE D (1135SQFT/105SQM)
TYPE A: 4BED+SERVENT , 2TOWERS(16 FLOORS EACH), 14 FLATS + 2
PENTHOUSES
TYPE B: 3BED+SEVENT, 4TOWERS
TYPE C: 3 BEDS, 2 TOWERS
TYPE D: EWS, STUDIO APARTMENTS, 1 TOWER,120FLATS (TOTAL)
FACILITIES (OTHER):
1. SOCIAL CLUB: INDOOR GAMES-SNOOKER,TABLE TENNIS,
CARD ROOMS
2. COMMUNITY HALL
3. PARTY HALL
4. DINING HALL
5. HEALTH CLUBS: GYM, STEAM SAUNA, JACUZZI, MASSAGE
THERAPY, MEDITATION, YOGA CENTRE.
6. ENTERTAINMENT CENTRE, FOOD CENTRE: ARE IN CLOSE
PROXIMITY
7. WATER SUPPLY
8. ALARM SYSTEM
9. SUFFICIENT BASEMENT PARKING
10. TRANSFORMER
11. PASSIVE ENERGY METHODS: SOLAR WATER PANELS, RAIN
WATER HARVEST
12. ONE GARBAGE SHOOT IN EACH FLOORS
13. FIRE EXIT STAIRCASE IN EACH BLOCK.
C
A
S
E
S
T
U
D
Y
ZONE(EARTHQUAKE): AS IF IT LIES IN ZONE4 SPECIAL
SPECIFICATIONS HAVE BEEN PROVIDED IN THE CONSTRUCTION.
EXAMPLE: SHEAR STIRRUPS HAVE BEEN PROVIDED DESIGNED IN
SUCH A WAY THAT SHEAR ZONE INCREASES AND BREADING
ZONE DECREASES.
FOUNDATION: RAFT FOUNDATION (150 MM THICKNESS)
PILE FOUNDATION PROVIDED: 300-360 PILES USED IN 1 BLOCK.
SOIL BEARING CAPACITY IS LESS.
CLC BRICKS AND AIR RAISED BRICKS ARE USED TO DECREASE
THE DEAD LOAD OF THE BUILDING.
SPECIFICATIONS:
STRUCTURE: SEMI LOAD BREAKING BRICK WALL, RCC FRAME
STRUCTURE
EXTERNAL FINISH-LONG LASTING PAINTS
WALL FINISH-INTERNAL WALL PLASTERED
TOILET WALLS- DADO UPTO 7-0 HEIGHT OF GLAZED CERAMIC
TILES
TOILET FLOORING- NON SKID TILES
FITTING-WASH BASIN,EWC, HOT AND COLD WATER SYSTEM
KITCHEN-PRE POLISHED GRANITE PLATFORM WITH STAINLESS
STEEL
DADO UP TO 2-0 HEIGHT ABOVE PLATFORM IN CERAMIC OR
GLAZED TILES
WINDOWS-POWDER COATED ALUMINUM WINDOW, WOODEN
WINDOWS, BRUSHED STEEL WINDOW
ELECTRICAL-COPPER CONCEALED WIRING, PROVISION FOR
LIGHTS, PLUG POINTS IN EACH BEDROOM, DRAWING, DRIVING
AND LOUNGE
FLOORING- VITRIFIED TILES. COMBINATION OF UDAIPUR GREEN
AND MARBLE IN STAIRCASE AND CORRIDOR
DOORS- HARDWOOD FRAMED, TEAK FURNISH FLUSH DOORS,
WOODEN ALMIRAH IN BEDROOM, GRANITE TOP PLATFORM,
MODULAR KITCHEN, POWER BACKUP.
MODULAR KITCHEN
CLC BRICKS
USED
MERITS:
1. THOUGH TYPES OF BLOCKS HAVE DIFFERENT PLANNING BUT
THE ELEVATION TREATMENT OF BLOCKS IS DONE IN SIMILAR
MANNER TO MAINTAIN UNIFORMITY. ELEVATION TREATMENT IS
DONE WITH ACP PANELS










2.. AN OPEN TERRACE OR GREEN AREA HAS BEEN PROVIDED ON
EACH BLOCK TO ENHANCE THE GREENERY OF THE SITE

3.ELEVATION OF EACH BLOCK IS NOT DONE IN ARE INDIVIDUAL
MANNER BUT IT WAS DONE IN SUCH A WAY THAT ALL THE BLOCKS
WERE COMBINED TOGETHER TO GIVE ONE SEAMLESS LOOK.

4.. AERATED BRICKS WERE USED IN UPPER FLOORS TO REDUCE
THE DEAD LOAD OF THE BUILDING STRUCTURE. THUS OUT OF THE
MAIN CONSIDERING EARTHQUAKE RESISTANCE ALONG WITH
INCREASING THE BEAUTY OF THE BUILDING.

5. MODULAR KITCHENS ARE USED (IMPORTED FROM CHINA) TO
MAINTAIN UNIFORMITY IN THE BUILDINGS.

6. SUFFICIENT
BALCONIES WERE
PROVIDED FOR EACH
RESIDENTIAL UNIT.

7. PROPER
VENTILATION WAS
PROVIDED FOR EACH
RESIDENTIAL UNIT.
37
8. FIRE SPRINKLER SYSTEM WAS PROVIDED IN TYPE A BLOCKS.
WHILE FIRE EXTINGUISHERS WERE PROVIDED IN EACH BUILDING
BLOCK. FIRE EXIT STAIRCASE IS PROVIDED IN EACH BLOCK.


















9. ENTERTAINMENT FACILITIES (GYMNASIUM/SWIMMING POOL)
WERE CENTRALLY PROVIDED THUS PROVIDING EASY ACCESS TO
ALL TYPES OF BLOCKS.

10. GARBAGE SHOOT PROVIDED IN EACH BLOCK.
11. BASEMENT. NUMBER OF CARS PROVIDED FOR EACH BLOCK.
13. SEWER DISPOSAL, WATER TANK, RAINWATER HARVESTING
FACILITIES IS PROVIDED.
14. UNITY IN DESIGN CAN BE SEEN
15. SECURITY POST AND ENTRANCE GATE GIVES GOOD
IMPRESSION.
16. APARTMENTS HAVE SEPARATE ENTRY.

DEMERITS:
1. HOUSES ARE TOO CONGESTED.
2. NO AS SUCH PASSIVE ENERGY.
3. LEED/GRIHA TECHNIQUES HAVE NOT BEEN USED.
4. PRESSURIZED FIRE EXITS HAVE NOT BEEN PROVIDED.
5. MIG,HIG,LIG,EWS: ALL NEARBY WITH NO SEGREGATION OF
UNITS THUS LEADING TO COMMOTION OF SPACE.
6.NEGATIVE SPACES
4.ALL THE BUILDING SERVICES SHOULD BE PROVIDED
COVERED PARKING ALONG WITH VISITORS PARKING IS NECESSARY

5.FIRE ESCAPE ARE TO BE FOLLOWED

5.WATER TANK SHOULD BE THERE ALONG WITH 1/3 WATER FOR FIRE
FIGHTING

6..ORIENTATION OF BUILDING IS VERY IMPORTANT SO AS FAR
POSSIBLE STICK TO CLIMATE
EG: BALCONIES SHOULD NOT BE PROVIDED IN SOUTH WEST
DIRECTION

7..FACILITIES LIKE DRINKING WATER POINT , GAS PIPELINE , POWER
BACK UP ARE THE CURRENT NEEDS

8.LANDSCAPING AND PLANNING OF ROADS IS IMP. AND
INTERCONNECTIONS BETWEEN GROUPS IS IMP.

9.PROVIDING BASEMENT IT SHOULD HAVE PROPER DRAINAGE
BATHROOM DUCTS , DRAINAGE SHOULD WELL EFFICIENT SO THAT
NO DAMPNESS OCCUR

10..TOWNSHIP SHOULD BE WELL DEVELOPED AND MAINTAINED
INFERENCES:


1. NOT MUCH SPACES HAVE BEEN PROVIDED FOR GREENERY

2. SITE TOO NEAR THE BUSH WOOD THUS INCREASING THE NOISE
POLLUTION.

3. NO PRIVACY IS SEEN. AS THERE WAS NO SEPARATION OF
MIG,HIG,LIG BLOCKS WERE SEEN.
CASE STUDY 2
OZONE CITY,ALIGARH
TYPE OF PROJECT : RESIDENTIAL TOWNSHIP & COMMERCIAL
DEVELOPMENT.

ARCHITECTS : GAUTAM & GAUTAM ASSOCIATES, FARIDABAD.

ABOUT THE PROJECT :
THE OZONE CITY PROJECT IS DEVELOPED BY THE OZONE GROUP
LTD. IT IS CONCEIVED AS A MIXED USE DEVELOPMENT &
INFRASTRUCTURE.IT COMPRISES OF DUPLEX HOUSING,
INDIVIDUAL PLOT HOUSING, HIGH RISE APARTMENT BUILDING,
SUPPORTING INFRASTRUCTURE SUCH AS HOSPITALS, PRIMARY
SCHOOL, COMMUNITY HALLS, AND COMMERCIAL
INFRASTRUCTURE SUCH AS SHOPPING MALL ETC.
SITE LOCATION
THE SITE IS LOCATED NEARLY 3 KM OFF THE MAIN G.T. ROAD
BYPASS. IT IS NEARLY 7 KMS FROM RAILWAY STATION & NEARLY
6 KM. FROM DHANIPUR AIR STRIP.THE SITE IS SURROUNDED ON
TWO SIDES BY ROADS.THE MAIN ACCESS ROAD IS TOWARDS
MAUHA KHERA DUE EAST AND OTHER ENTRY IS FROM A
PROPOSED DELHI-KANPUR BY-PASS ROAD TOWARDS NORTH.
ACCESS ROAD
SITE LAYOUT
THE TOWNSHIP IS DESIGNED ON A RECTANGULAR GRID PATTERN
WITH A 18 M ROAD IN CENTRE.THE ROADS INTERSECT AT RIGHT
ANGLES.THE VARIOUS HOUSING CLASSES ARE DIVIDED AREA
WISE AND ARE ALLOTTED SPECIFIC AREAS. THE ENTRY IS FROM
TWO SIDES. THE SITE HAS A TOTAL AREA OF 125 ACRES,WHICH IS
TO BE DEVELOPED IN PHASES .PHASE 1 COMPRISES OF LIG (2BHK)
& MIG (3BHK) HOUSING DEVELOPMENTS, & PHASE 2 CONSIST OF
HIGH RISE APARTMENT INFRASTRUCTURE .THERE IS ALSO
SCHEME FOR RESIDENTIAL PLOTS. THE SITE HAS A 55 % OPEN
SPACE, WHICH IS UTILISED FOR DEVELOPING GREEN AREAS.

FOLLOWING ARE THE SUPPORTING INFRASTRUCTURES:
1. NURSING HOME.
2. A PRIMARY SCHOOL & A NURSERY SCHOOL.
3. RECREATIONAL CLUB.
4. FOUR SHOPPING MALLS.
5. WATER TREATMENT PLANT.
6. ELECTRIC SUBSTATION ETC.
MODEL SHOWING THE ENTRANCE FROM SIDE.
HIGH RISE BUILDINGS HAVE
A SEPERATE AREA.
FEATURES (HOUSING)
THE HOUSING SCHEME COMPRISES OF 1 BHK, 2 BHK,
3BHK,DUPLEXES,APARTMENTS AND INDIVIDUAL PLOTS.
FACILITIES & SPECIFICATIONS OF G+2 100
SQ.YARDS

THE CHARACTERISTICS OF THE LIG HOME PROVIDED BY THE
OZONE CITY :-
ROW HOUSING DEVELOPMENT HAS BEEN DONE.
EARTHQUAKE RESISTANT STRUCTURE
HUGE SIT OUT BALCONIES
PROVISION FOR
R.O. WATER
POLLUTION AND
NOISE FREE
ENVIRONMENT
MAXIMUM
UTILIZATION OF
SPACE
DEDICATED CAR
PARKING
PROVISION FOR
MODULAR
KITCHEN.
PLAN OF A
1 BHK HOUSE
150
SQ.YARDS
ROW
HOUSING
PROJECT
The bedrooms are spacious & the
west sun is allowed inside the
room through the window. But a
serious flaw is that morning sun is
completely blocked
AN OUTSIDE VIEW OF A 2
BHK RESIDENTIAL
BUILDING. EXCELLENT
ELEVATION TREATMENT.
200 SQ.YARDS ROW HOUSING FOR MIG GROUP
INFERENCES
The housing units are well designed & makes intelligent use of the
space. though the design of dwelling units are not climate sensitive &
the buildings are not oriented climatically.
There is a visual differentiation between various classes of units.
The front setback of the scheme is very less, the building blocks start
just after the main gate.
There is no individual parking space for each unit.
There is no entrance to the shaft in the 2 bhk unit.
The overall location of the site makes it very difficult to approach.no
public transport available .though the future planning indicates the
g.t. road bypass passing right by the side of the site which makes it
promising.
Separate community spaces are provided for each residential area.
No fire fighting system is provided.
The staircase is cramped.
The township is well serviced & well maintained. water is supplied
through overhead tank located within the site.
CONCLUSION
Although the scale of the project is very large, there is ample scope in the
project. the design of the dwelling units is good and provides a good
opportunity to learn the very nature of housing schemes.
LOCATION:- SECTOR 93B, NOIDA, UTTAR PRADESH

ACCESS :-NOIDA-GREATER NOIDA EXPRESSWAY

SITE SURROUNDING:- A COLLEGE IN FRONT AND OTHER GROUP
HOUSING LIKE ALDICO ETC. ARE IN ITS VICINITY.

TOTAL FLATS- 1320 FOR 5600 PEOPLE .

TYPES OF HOUSES:- 2BHK , 3BHK AND 3BHK+SERVENT QUARTER

OTHER FACILITIES :-
-SPA
-BANQUET HALL
-RESTAURANT
T.T ROOM
BILLIARDS, CAROM ETC.
-SWIMMING POOL
-PARKS
-SHOPS
-YOGA
FACILITIES :-
WATER SUPPLY
ALARM SYSTEM
SUFFICIENT BASEMENT PARKING
GENERATORS
TRANSFORMER
PUMP ROOM IN BASEMENT
SECURITY CAMERAS AND TIGHT SECURITY AT THE GATE WITH
MODERN TECHNOLOGY SCREENING SYSTEM GATES FOR
VEHICLE PASS
DRINKING WATER SUPPLY PIPES
PASSIVE ENERGY METHODS USED LIKE SOLAR PANELS, RAIN
WATER HARVESTING, ETC.
GOOD ENVIRONMENT FOR PEDESTRIAN DANCE FLOOR
CANOPIES, SLOW MUSIC IS PLAYED IN MORNING AND EVENING
FOR REFRESHMENT OF PEOPLE WHO ARE TAKING MORNING
WALK ETC.
OMAXE GRAND WOODS NOIDA
CASE STUDY
3 BHKS WITH STUDY: 1900 SQFT
MIG HOUSING UNIT :150 SQ.M (AREA)
ELEVATION
GRID IRON PATTERN USED
SEWER DISPOSAL , WATER TANK , ELECTRICITY POLES,
TWO LANE ROADS ARE POSITIVE POINT
SEWER DISPOSAL PLANT IS ALSO THERE
FACILITIES LIKE PARKS, CLUB , SHOPPING COMPLEX
INCREASES ITS IMPORTANCE.
DWELLING UNITS ARE WELL VENTILATED
PURDAH IS TAKEN IN CONSIDERATION THEREFORE EACH
HOUSE HAS TWO DOORS FROM OUTSIDE ONE OPENING
IN DRAWING ROOM OTHER IN LOBBY
ALL OTHER HOUSES WHOSE PLOTS HAS BEEN BOOKED
ARE REQUIRED TO HAVE THE SAME EXTERIOR AS
INTERIOR
ALL THE DWELLING UNITS WHETHER HIG , MIG,LIG HAVE
SAME EXTERIOR ONLY INTERIORS DIFFER
UNITY IN DESIGN CAN BE SEEN
SECURITY POST AND ENTRANCE GATE GIVES A GOOD
IMPRESSION
MERITS
HOUSES ARE TOO CONGESTED
HOSPITAL IS AT ONE CORNER WHICH SHOULD BE
SOMEWHERE AT THE CENTER SO THAT EASILY ACCESIBLE.
THE DELHI- KANPUR HAS NOT BE DEVELOPED AND SO ITS
HAS BECOME A MAJOR REASON FOR ITS
UNSUCCESSFULNESS
TOO MUCH OF SHOPPING COMPLEX HAS BEEN PROVIDED
WHICH IS NOT NEEDED
SITE SURROUNDING IS NOT SO DEVELOPED
NO AS SUCH USE OF PASSIVE ENERGY
SEWER PLANT IS ALMOST OPEN WHICH IS ALSO A
PROBLEM FOR THOSE WHO ARE LIVING BESIDE IT
PARKING FACILITIES ARE NOT VERY GOOD
VISITORS PARKING SPACE IS YET TO BE DECIDED
FLATS ARE NOT THAT LUXURIOUS
APARTMENT SHOULD HAVE SEPARATE ENTRY
DEMERITS
PROPER COMMUNITY ZONES LIKE CLUBS, PARKS SHOULD BE
PROVIDED FOR PEOPLE TO INTERACT AND ENJOY
COMMERCIAL PLACE, HOSPITAL, SCHOOLS ARE ALSO BASIC
NEED
APPROACH ROAD SHOULD BE WIDE ENOUGH
PRIVACY SHOULD BE MAINTAINED
VENTILATION SHOULD BE MAINTAINED
NOISE CONTROL AND OTHER KIND POLLUTION SHOULD BE
CHECKED OUT.
PASSIVE ENERGY METHODS AND RAIN WATER HARVESTING
SHOULD BE IMPLIED
ALL THE BUILDING SERVICES SHOULD BE PROVIDED
COVERED PARKING ALONG WITH VISITORS PARKING IS
NECESSARY
FIRE ESCAPE ARE TO BE FOLLOWED
WATER TANK SHOULD BE THERE ALONG WITH 1/3 WATER FOR
FIRE FIGHTING
ORIENTATION OF BUILDING IS VERY IMPORTANT SO AS FAR
POSSIBLE STICK TO CLIMATE
E.G.: BALCONIES SHOULD NOT BE PROVIDED IN SOUTH WEST
DIRECTION
FACILITIES LIKE DRINKING WATER POINT , GAS PIPELINE ,
POWER BACK UP ARE THE CURRENT NEEDS
LANDSCAPING AND PLANNING OF ROADS IS IMP. AND
INTERCONNECTIONS BETWEEN GROUPS IS IMP.
IF PROVIDING BASEMENT IT SHOULD HAVE PROPER DRAINAGE
BATHROOM DUCTS , DRAINAGE SHOULD WELL EFFICIENT SO
THAT NO DAMPNESS OCCUR
TOWNSHIP SHOULD BE WELL DEVELOPED AND MAINTAINED
INFERENCES
51
NRI RESIDENCY OZONE CITY OMAXE GRAND
WOODS
INFERENCE
PLANNING U-SHAPED
PLANNING,
APARTMENTS
ALONG THE
BOUNDARY OF SITE
WHILE THE GREEN
SPACE IN
BETWEEN.
GRID IRON PATTERN,
ROAD INTERSECTS AT
RIGHT ANGLES
SITE PLANNING:
BLOCKS
SURROUNDED BY
GREEN
COURTYARD, OPEN
SPACE WITH
PERIPHERAL ROAD
FOR THE VEHICLE
MOVEMENT.
RECREATIONA
L CENTRE TO
BE PLACED AT
A PLACE
WHERE
MAXIMUM
NO. OF FLATS
CAN HAVE
VIEW OF
GREEN
SPACES.
2 BHK 1110
SQFT./103SQM

3 BHK 1135SQFT./105SQ
M
1600SQFT./150SQ
M

3 BHK+
SERVANT
1215SQFT./113SQ
M
1900SQFT./180SQ
M

4 BHK 1490SQFT./139SQ
M

4 BHK+
SERVANT
2200SQFT./205SQ
M
280SQM &
340SQM

PENTHOUSE
(3BHK+SERVENT
)
-
PENTHOUSE
(4BHK+SERVENT
)
BY HAMZA
VILLAS - TYPE A- 100SQ
YARDS/602.6SQFT
TYPE B-150SQ
YARD/790.9SQFT

CIRCULATION HORIZONTAL
CIRCULATION IS
CONVENIENT.
ATLEAST 2 LIFTS
ARE PROVIDED FOR
VERTICAL
MOVEMENT. NO
PROPER
SEGREGATION OF
SPACES.
AS IT IS DESIGNED ON
GRID IRON LAYOUT IT
REVEALS A WELL
PLANNED SYSTEMATIC
PLANNING WITH
PROPER SEGREGATION
OF VARIOUS SPACES.
EG:
MIG,LIG,HIG,DUPLEXES
, VILLAS ETC.
HORIZONTAL
CIRCULATION IS
CONVENIENT,
VEHICULAR
MOVEMENT WERE
WELL PLANNED.
PROPER
SEGREGATION OF
SPACES.
PROPER
SEGREGATION
OF SPACES IS
NEEDED TO
MAINTAIN
THE PRIVACY
LEVEL. AT
LEAST 2
STAIRCASES,
ONE FOR THE
FIRE EXIT;
PROPER
PEDESTRIAN
AND
C
O
M
P
A
R
I
T
I
V
E
A
N
A
L
Y
S
I
S
COMPARITIVE ANALYSIS
FACILITIES SOCIAL CLUB,
COMMUNITY
HALL, PARTY HALL,
DINING HALL,
HEALTH CLUB,
SECURITY
RECREATIONAL
CLUB,
PRIMARY SCHOOL,
SHOPPING MALLS.
LAWN TENNIS
COURTS,
BASKETBALL
COURTS,
RECREATIONAL
CENTRE,
GROCERY,
SECURITY.
RESTAURANTS
SHOULD NOT BE
OPEN TO ALL IF IT
IS THERE.
RESTRICTED
MOVEMENTS OF
VISITORS ARE
REQUIRED. A CLUB
HOUSE IS
NECESSARY TO
PROVIDE
ENTERTAINMENT
FACILITIES TO
RESIDENTS.
Light and
ventilation
Proper light and
ventilation for
each residential
unit.
Spacious rooms,
morning sun
blocked as no
rooms in east
direction.
Adequate light
due to open
spaces, sunshades
louvers are
provided for
climatic control.
Direct sunlight in
at least living
room, ventilation
shafts of toilets
are important.
Architectural
character
Residential
character with
recreational
activities
Residential
character with
recreational
activities.
Excellent
treatment of
elevations.
Residential
character
Buildings must
show some
particular
character. There
must be unity in
the form of
design.
Building services Window AC are
provided, 2lifts in
each block, fire
fighting sprinkler
and extinguisher is
provided in each
block,pump
room,electrical
room, water
storage tank,
rainwater
harvesting facility
provided along
with use of solar
panel.
Earth resistant
structure,no fire
fighting system
provided,
Staircase cramped,
Water supply
through overhead
tanks.
Window ACs and
split units, 2 lifts in
each block, fire
fighting hose pipes
and extinguisher
on each floor,
water storage
tank, pump room
and electrical
room
2 lift in each block,
fire fighting
facilities provided,
pump room,
electrical room,
water storage
tank, and rain
water harvesting
facilities available.
External finishes Under
construction but
elevation is
treated with ACP
paneling
Plastered walls Stone cladding can
be used to be
maintenance free
for years.
Parking Basement parking No individual
parking for each
unit.
One level
basement parking
and surface
parking
Proper parking for
visitors should also
be available.


Clubhouse Total area in sqm
Outdoor swimming pool 150-200
Gymnasium 120
Billiards room & gaming area 200
Cards room 120
Table tennis 150
Meditation, yoga & aerobics 150
Entertainment and relaxation complex 100
Lobby 100
Toilets 50
Reading room 100
Spa 400
Restaurant 250
Total 1890


Parking No.of cars Total area
Basement parking
Surface parking
Drivers lounge


Amenities Total area (in sqm)
Childrens park 110
Basketball court 195
Lawn tennis court 195
Nursery school 350

ACN COLLEGE
POLICE LINE
ROAD

Das könnte Ihnen auch gefallen