Beruflich Dokumente
Kultur Dokumente
May 3, 2006
Methods:
Electrolytic Analysis of Cu in an Ore
In order to find the electrolytic analysis of Cu in an Ore, we precisely
weighed out a 3.4585 g of the unknown (#75) ore sample into a 250
ml beaker. We then added 25 ml of de-ionized water, 2 ml of
concentrated sulfuric acid, and 1 ml of concentrated nitric acid. We
then heated the mixture over a hot plate until no more dissolving
occurs. We then cooled the solution and diluted it with de-ionized
water to a 100 ml volume. We then used the, Eberbach Corp #6,
electrolysis machine (serial # 749864) to stir the electrodes in the
beaker of solution for approximately 30 minutes at 3 volts and 1.4
amperes. We then added de-ionized water to bring the volume of
solution up and continued the process. We repeated the adding of
de-ionized water and the stirring of solution until no more blue color
remained in the solution and no further copper plating was observed.
Spectrophotometric Analysis of Cu in an Ore
In order to find the spectrophotometric analysis of Cu in an Ore, we
made a 0.0500 M Cu2+ solution by pouring 35 ml of the stock 0.100
M Cu2+ solution and transferring 25.00 ml