A-3 GROUND FLOOR PLAN
3 A-4 SECOND FLOOR PLAN _________________________________
SCHEDULE OF DOORS
11 SCHEDULE OF WINDOWS
SANITARY
E-1 FIRST FLR. ELECTRICAL PLAN
12 E-2 2ND FLR. ELECTRICAL PLAN
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE
PROPOSED TWO-STOREY RESIDENTIAL
BUILDING GIRLEY T. SANICO
1
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15
THIS SITE
1.
25
m
N
1.
95
PAT
m
HW
ALK
K
L 4.
25
m
A m
3.
5
W .0
15
10
10
H
.2
T
m0
PAT BLOCK 33
0m HW
A 1.
1 ALK
P
PR
O
RI
PE
DG
m
50
RT
3.
E
2. LOT 7
80
Y
LI
m
NE
m
RI
95
DG
0.
E
BLOCK 34
RO
LL
1.
R O
25
A D
m
2.
50m
RI
BLOCK 35
DG
E
RO
LL
PR
L O T
O
PE
RD
3.
R
TY
20
YA NE
LI
m
LI
N ICE Y
E
RV RT
SE PE
10
O
PR BLOCK 39
.2
5
5m
m
00
9.
3.
35
m
LOCATION/VICINITY MAP
A SITE DEVELOPMENT PLAN NOT DRAWN TO SCALE
2 SCALE: 1 : 100
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014 PROPOSED TWO-STOREY RESIDENTIAL
Issued At: CARIGARA,LEYTE BUILDING
2
JANE YVONNE J. JACOBE, CE GIRLEY T. SANICO
REG. No. 0095507 TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE OWNER 15
1 3 4 6 7 1 3 4 6 7
8.20m 8.20m
1.60m 1.15m 3.10m 2.35m 1.70m 1.05m 0.95m 1.20m 0.80m 2.50m
F F
1.70m
1.70m
2.00m
2.00m
CANOPY
2.70m D W
2 BEDROOM KITCHEN 3 BEDROOM
3.25m
3.25m
W FAMILY HALL W
3.80m
3.80m
4 3
E DINING
CANOPY
1.55m
1.55m
D
W D DOWN
2
D
1.80m
1.80m
5 W 4
4
1.10m
5
D D
D
7.10m
7.10m
5 3 D
C 1.80m
D
5
4
2.65m
2.65m
OPEN
CANOPY
2.15m
2.15m
3.35m
3.35m
W W BEDROOM
2.60m
2.60m
3 LIVING GARAGE 3 BALCONY
0.95m D UP D
1 2
B 0.95m
B
0.70m
0.70m
0.20m W
2 0.20m
ENTRY TERRACE
A W 0.55m
CANOPY
W CANOPY
0.50m A
0.70m 1 0.60m 0.70m 1
1.00m 1.00m
8.20m 8.20m
1 2 3 4 5 6 7 1 2 3 4 5 6 7
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014 PROPOSED TWO-STOREY RESIDENTIAL
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE BUILDING GIRLEY T. SANICO
3
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15
1 2 3 5 6 7 7 6 5 4 1
8.20m 8.40m
0.20m
0.50m 1.00m 3.00m 1.10m 2.40m 0.20m 3.50m 4.70m 0.20m
0.20m
0.20m
TOP OF PARAPET
0.80m
0.80m
0.65m
0.65m
4" CHB PARAPET 0.20m 4" CHB PARAPET
TOP OF BEAM TOP OF BEAM
2ND FLOOR CEILING LINE 2ND FLOOR CEILING LINE
W D
2.60m
2.60m
2.60m
2 D W
2.55m
1 3
2 ANALOK FRAME
1"x1 21" Analok Rect. Tube TWO-LEAF
ANALOK FRAME
1
4" Glass Panel Analok Frame SLIDING WINDOW
0.30m
6.65m
6.65m
2ND FLR. LINE
BALCONY FLR. LINE
0.70m
2.65m
W W
2.60m
3.00m
2.25m
2 W
1 D ANALOK FRAME
3
TWO-LEAF D
1 D 2
ANALOK FRAME
3 ANALOK FRAME 0.15m
TWO-LEAF SLIDING WINDOW
1ST FLR. LINE
0.35m
0.20m
8.20m
8.20m
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014 PROPOSED TWO-STOREY RESIDENTIAL
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE BUILDING GIRLEY T. SANICO
4
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15
A B D F F C B A
7.20m 7.20m
0.20m
0.20m
1.00m 2.60m 3.45m 3.80m 2.30m 0.90m
TOP OF PARAPET
0.75m
0.80m
0.65m
4" CHB PARAPET 4" CHB PARAPET
TOP OF BEAM TOP OF BEAM
ANALOK FRAME ANALOK FRAME
SLIDING WINDOW AWNING WINDOW
3.35m
W
2.60m
2.55m
2.70m
W W W W W
6 3 3 3 1
5
6.65m
SLIDING WINDOW SLIDING WINDOW CORNER FIXED
6.50m
SLIDING WINDOW
2ND FLR. LINE
BALCONY FLR. LINE
2.70m
2.75m
2.75m
W W W
W W
2.75m
4 3 1
3 5
ANALOK FRAME
AWNING WINDOW
0.25m ANALOK FRAME
ANALOK FRAME
SLIDING WINDOW
ANALOK FRAME 0.30m
CORNER FIXED
SLIDING WINDOW
1ST FLR. LINE
KITCHEN FLR. LINE
FIN. GRADE LINE FIN. GRADE LINE
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014 PROPOSED TWO-STOREY RESIDENTIAL
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE BUILDING GIRLEY T. SANICO 5
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15
S COLUMN DETAIL
4 NOT DRAWN TO SCALE
1 3 4 6 7
REBARS ALONG B
8.20m
C1
200 mm x 350 mm
2.75m 4.05m 1.35m 10mm LATERAL TIES SPACED
1 - 50mm, 5 - 100mm, 4 - 150mm
REBARS ALONG A REST @ 200mm FROM SLAB TO
1.60m 1.15m 3.10m 2.35m MIDHEIGHT
1.70m
F2-C2 F2-C2 F2-C2 250 mm x 250 mm
2.00m
F2-C2
4" C.H.B. WALL (TYPICAL) 10mm LATERAL TIES SPACED
2.70m
Elev. 250mm
Elev. 250mm 1 - 50mm, 5 - 100mm, 4 - 150mm
3.25m
REST @ 200mm FROM SLAB TO
3.80m
1.55m
(TYPICAL)
1.80m
Elev. 200mm
1.10m
D
7.10m
7.10m
F2-C2 F2-C2
C F1-C2 F1-C2 F1-C2
2.65m
4" CONCRETE NATURAL GRADE LINE
2.15m
0.80m
3.35m
SLAB ON FILL 4" thick CONCRE HOLLOW BLOCKS
2.60m
B Elev. 350mm
B MAIN VERTICAL BARS
1.20 m
0.20m F2-C2
Elev. 200mm F2-C2 F2-C2
A F1-C1 F1-C1
RAMP
0.50m A
0.70m STAIR UP 0.20 m BARS SPACED AT 300mm O.C.
0.30 m
1.00m
0.40 m
3.00m 2.50m
0.70m 1.00m
WALL FOOTING
2.85m 1.85m 3.50m DETAIL SECTION
S (A or B)
FOOTING DIMENSION
5 SCALE: 1:30
8.20m
1 2 3 4 5 6 7
SCHEDULE OF FOOTING
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014 PROPOSED TWO-STOREY RESIDENTIAL
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE BUILDING GIRLEY T. SANICO
6
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15
1 3 4 6 7 1 3 4 6 7
8.20m 8.20m
1.70m 1.05m 0.95m 1.20m 0.80m 2.50m 1.70m 1.05m 0.95m 1.20m 0.95m 2.35m
1.70m
1.70m
2.00m
3.25m
3.25m
RB2
RB1
RB1
2B1
2B3
3.80m
2B1
S-3
RB2
2B3
E S-1 S-2
1.55m
1.55m
2B3
1.80m
2B2 RB1 D
7.10m
7.10m
7.10m
2B2 2B2 RB1 RB1
C STAIR
WELL
2.65m
2.65m
2B3
RB1
RB2
2.15m
2B1
2B1
RB1
3.35m
3.35m
2B3
S-4 S-5
3.30m
S-6
0.95m
0.70m
0.70m
0.20m
S-7 2B1
2B4
A 2B4
0.50m
RB1
0.50m A
1.00m 1.00m
8.20m 8.20m
1 2 3 4 5 6 7 1 2 3 4 5 6 7
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE
PROPOSED TWO-STOREY RESIDENTIAL
BUILDING GIRLEY T. SANICO
7
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15
LONG SPAN (L)
SCHEDULE OF SLAB
SLAB No. SIZE (m) THICKNESS (mm) TOP REBARS BOTTOM REBARS
L/4 L/2 L/4 S1 2.80 x 3.80 100
SHORT SPAN 12 mm 300 mm ON CENTER
LONG SPAN 00 mm ON CENTER 300 mm ON CENTER
SHORT SPAN 12 mm 300 mm ON CENTER
S2 3.00 x 3.80 100
LONG SPAN 00 mm ON CENTER 300 mm ON CENTER
SHORT SPAN 300 mm ON CENTER 300 mm ON CENTER
S3 2.50 x 3.30 100
S/4
TOP REBARS LONG SPAN 12 mm 300 mm ON CENTER
TOP REBARS
SHORT SPAN (S)
Span (L)
LEFT END RIGHT END
TOP REBARS
0.10 m
D
BOTTOM REBARS B
L/4 L/2 L/4 SEE SCHEDULE
SCHEDULE OF BEAMS
SIZE (mm) REINFORCEMENTS
BEAM No. LOCATION
B D LEFT END MID SPAN RIGHT END
TOP 4 4
2B1 200 350 1 @ 50mm, 5 @ 100mm, 4 @ 150mm, REST @ 200mm
BOTTOM 3 3 3
TOP 3 3
2B2 200 400 1 @ 50mm, 5 @ 100mm, 4 @ 150mm, REST @ 200mm
BOTTOM 3 3 3
TOP 4 3 4
2B3 250 400 1 @ 50mm, 5 @ 100mm, 4 @ 150mm, REST @ 200mm
BOTTOM 4 4 4
TOP 3 3
2B4 200 300 1 @ 50mm, 5 @ 100mm, 4 @ 150mm, REST @ 200mm
BOTTOM 3
TOP 3 2 3 - 12
RB1 200 250 1 @ 50mm, 5 @ 100mm, 4 @ 150mm, REST @ 200mm
BOTTOM 2 2 2
TOP 3 - 12 2 3 - 12
RB2 200 300 1 @ 50mm, 5 @ 100mm, 4 @ 150mm, REST @ 200mm
BOTTOM 3 - 12 3 - 12 3 - 12
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014 PROPOSED TWO-STOREY RESIDENTIAL
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE BUILDING GIRLEY T. SANICO
8
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15
1 3 4 6 7 1 3 4 6 7
8.20m 8.20m
1.70m 1.05m 0.95m 1.20m 0.95m 2.35m 1.70m 1.05m 0.95m 1.20m 0.95m 2.35m
3
2"x4"x16 " C-PURLINS
4" C.H.B. PARAPET @ 0.60m O.C. 3 Layers 4" Thick C.H.B. PARAPET
F DS
T-1
DS DS DS
F
1.70m
1.70m
2.00m
2.00m
CANOPY
CANOPY
RIDGE ROLL
R.C. GUTTER
3.25m
3.25m
R.C. GUTTER
R.C. GUTTER
R.C. GUTTER
3.80m
RIDGE
E
CANOPY
CANOPY
1.55m
1.55m
1.80m
1.80m
DS DS
D
7.10m
7.10m
DS T-1 DS
C DS
T-2
DS
TURNBUCKLE
DS DS
R.C. GUTTER
R.C. GUTTER
(TYPICAL)
R.C. GUTTER
RIDGE ROLL
2.65m
2.65m
R.C. GUTTER
CANOPY
CANOPY
12 mm CROSS
2.15m
2.15m
RIDGE
3.35m
3.35m
BRACING
3.30m
B
DS T-2 DS DS DS
0.70m
0.70m
0.20m 0.20m
RIDGE
RIDGE
CANOPY
CANOPY
T-3
A CANOPY
0.50m
CANOPY
0.50m A
1.00m 1.00m
8.20m 8.20m
1 2 3 4 5 6 7 1 2 3 4 5 6 7
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014 PROPOSED TWO-STOREY RESIDENTIAL
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE BUILDING GIRLEY T. SANICO
9
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15
1 4.10 m
S TRUSS-1 DETAIL PREPAINTED COLOR ROOF
0.80 m
0.70 m
2 S- 2" x 2" x 41"
2 S-1 21" x 1 21" x 41"
KING POST
4.10 m
0.10 m
5.30 m 13 SECOND FLOOR LINE
12
1.25 m 0.70 m 0.70 m 0.70 m 0.70 m 1.25 m
11
0.
81 10
200mm ON CENTER
0.45 m
m
9
0.25 m 0.25
2.26 m
8
0.25 m
1. 7
0.23 m 0.23 m
S TRUSS-2 DIAGRAM
2.95 m
65
2.85 m
3. m 6
27
0.23 m
13 SCALE: 1:30 m
5
4
0.
81 3
4.00 m m
2
0.69 m
1.30 m 0.70 m 0.70 m 1.30 m
1
0.34 m
S TRUSS-3 DIAGRAM
14 SCALE: 1:30 S STAIR DETAIL
15 SCALE: 1:30
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014 PROPOSED TWO-STOREY RESIDENTIAL
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE BUILDING GIRLEY T. SANICO
10
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15
1.40 m 1.40 m 0.70 m 0.70 m 0.60 m
SCHEDULE OF DOORS
SCALE: 1:30
2.10 m
2.10 m
2.10 m
2.10 m
2.10 m
FINISH FLOOR LINE
D D D D D
1 2 3 3 3
ANALOK FRAME ANALOK FRAME ANALOK FRAME FLUSH-TYPE HOLLOW PVC DOOR
TWO-LEAF ENTRANCE DOOR TWO LEAF DOOR FLUSH TYPE CORE
SCHEDULE OF WINDOWS
0.20 m
SCALE: 1:30
0.30 m
0.40 m
0.80 m
1.45 m
1.45 m
1.45 m
1.90 m
1.30 m
0.65 m
0.65 m
0.65 m
FINISH FLOOR LINE
W W W W W W
1 2 3 4 5 6
ANALOK FRAME ANALOK FRAME ANALOK FRAME ANALOK FRAME ANALOK FRAME ANALOK FRAME
SLIDE UP WINDOW CORNER WINDOW SLIDING WINDOW AWNING WINDOW AWNING WINDOW SLIDING WINDOW
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014 PROPOSED TWO-STOREY RESIDENTIAL
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE BUILDING GIRLEY T. SANICO 11
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15
1 3 4 6 7 1 3 4 6 7
8.20m 8.20m
1.60m 1.15m 3.10m 2.35m 1.70m 1.05m 0.95m 1.20m 0.80m 2.50m
F REF
9
F
1.70m
1.70m
2.00m
2.00m
2.70m
3.25m
3.25m
3.80m
3.80m
E 11
S3
S1 8
1.55m
1.55m
AC
4
S2
10 S2W S3
1.80m
1.80m
6 R S2
S1 2
1.10m
S2 S3
3
D
7.10m
7.10m
S1 S2
LPP
S1 S1
C 5 12
AC
S3
2.65m
2.65m
2.15m
2.15m
1
3.35m
3.35m
2.60m
2.60m
0.95m
S2 S2W 7
B
S1
B 0.20m S3
S3
S1
0.95m
0.20m
S3
A 0.55m 0.50m A
0.70m 0.70m
1.00m 1.00m
8.20m 8.20m
1 2 3 4 5 6 7 1 2 3 4 5 6 7
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014 PROPOSED TWO-STOREY RESIDENTIAL
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE BUILDING GIRLEY T. SANICO
12
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15
CELING FLOOR LINE
TO POWER SOURCE SPECIFICATIONS LEGEND
C3 C4
SYMBOL DESCRIPTION
1. ALL ELECTRICAL WORKS SHALL COMPLY IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. THE APPLICABLE PROVISIONS
OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE. THE RULES AND REGULATION OF THE LOCAL ENFORCING AUTHORITY FLUORESCENT LAMP
TO POWER SOURCE
AND THE REQUIREMENTS OF THE LOCAL POWER COMPANY. THE ELECTRICAL WORKS SHALL BE DONE UNDER THE IMMEDIATE
LPB SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER. PIN LIGHT
100 AT
C7 C8 C11 C12 2. THE ELECTRICAL SERVICE POWER IS 1-PHASE, 2-WIRE, 240 V AC, 60Hz. INCANDESCENT WALL LAMP
1 2 3. WIRING METHOD SHALL BE AS FOLLOWS:
20 AT 20 AT CONVENIENCE OUTLET
7 8
20 AT 20 AT S1 ONE GANG DEVICE SWITCH
5. ALL OUTLET BOXES SHALL BE GALVANIZED GAGE No. 16 DEEP TYPE WITH FACTORY KNOCKOUTS
9 10 S2 TWO GANG DEVICE SWITCH
20 AT 40 AT 6. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND APPROVED TYPE FOR THE PARTICULAR LOCATION AND PURPOSE USAGE.
C5 C6 C9 C10 S3 THREE GANG DEVICE SWITCH
11 12 7. GROUNDING SYSTEM SHALL BE PROVIDED TO ALL LIGHTING AND POWER CIRCUIT AS PER PHILIPPINE ELECTRICAL CODE REQUIREMENT
20 AT 20 AT S2W TWO WAY SWITCH
8. MOUNTING HEIGHT OF WIRING DEVICES SHALL BE AS FOLLOWS:
GROUND FLOOR LINE RACEWAY CONDUIT CONCEALED IN CEILING
A. PANEL BOARD SHALL BE LOCATED 1.50 m ABOVE FINISH FLOOR LINE.
GROUND RACEWAY CONDUIT CONCEALED UNDER FLOOR
B. ALL LIGHT SWITCHES SHALL BE 1.20m ABOVE FINISH FLOOR LINE.
PANEL BOARD
C. CONVENIENCE OUTLET SHALL BE 0.30m ABOVE FINISH FLOOR LINE.
SINGLE LINE RISER DIAGRAM FEEDER DIAGRAM
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014 PROPOSED TWO-STOREY RESIDENTIAL
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE BUILDING GIRLEY T. SANICO
13
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15
1 3 4 6 7 1 3 4 6 7
8.20m 8.20m
1.60m 1.15m 3.10m 2.35m 1.70m 1.05m 0.95m 1.20m 0.80m 2.50m
F F
FAU
DS DS DS DS
1.70m
2.00m
2.00m
KS
3.25m
3.80m
3.80m
E FD
1.55m
FD
WC
1.80m
1.80m
WC
D
7.10m
DS DS DS
7.10m
FAU LAV DS
LAV
FAU FD
C
DS DS
2.65m
2.15m
2.15m
3.35m
2.60m
2.60m
SEPTIC
VAULT
B DS 0.95m DS
B
0.95m
0.20m
0.70m
FD
TO DRAINAGE CANAL
A 0.50m A
0.20m 0.70m
M
1.00m 1.00m
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014 PROPOSED TWO-STOREY RESIDENTIAL
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE BUILDING GIRLEY T. SANICO
14
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15
P SEPTIC VAULT DETAILS
3 SCALE: 1:35
LEGEND: 0.10 m
1.20 m
2.30 m
0.10 m
0.80 m
0.10 m
0.10 m
WC WATER CLOSET
LAV LAVATORY
1.10 m
1.30 m
C.O. MANHOLE MANHOLE C.O.
DS DOWNSPOUT PLAN
FAU FAUCET
C.O. C.O.
400mm x 400mm 400mm x 400mm
0.10 m
SOIL PIPE LINE INLET PIPE
AIR SPACE
OUTLET PIPE
WATER LINE
1.50 m
DIGESTIVE CHAMBER LEACHING
M WATER METER 100 mm thk CHB spaced every 3rd Layer
CHAMBER
0.20 m
SECTION
0.10 m 1.20 m 0.80 m
0.10 m 0.10 m
2.30 m
DRAWN BY: PTR No. 7623541 PROJECT TITLE: APPROVED: SHEET No.
Issued On: July 18, 2014 PROPOSED TWO-STOREY RESIDENTIAL
JANE YVONNE J. JACOBE, CE Issued At: CARIGARA,LEYTE BUILDING GIRLEY T. SANICO 15
REG. No. 0095507
TIN: 932-817-659 LOCATION: BRGY. CANDAHUG, PALO, LEYTE
OWNER 15