PHONE: 91-22-2667-4506 or 2667-4787, FAX: 91-22-2667-2737, E-MAIL: systech@bom4.vsnl.net.in SOFTWARE VALIDATION TEST REPORT FOR TRIFLEX - PIPING SYSTEM DESIGN & ANALYSIS PROGRAM, (PREPROCESSOR VERSION 1.1.2, ANALYSIS - FEM - STIFFNESS, VERSION 1.7.9) Reference: Bezler, P., Subudhi, M. and Hartzman, M., "Piping Benchmark Problems", Dynamic Analysis independent Support Motion Response Spectrum, Regulatory Commission, NUREG/CR-1677, Vol. 2, August 1985. Modal Analysis Program Verification This section presents a comparison of the program-generated solution with a known solution of a selected benchmark problem. This provides a confirmation of the adequacy of the program for modal analysis of piping systems. Benchmark Problem It simulates a 3-1/2 inch diameter water line extending between two elevations. It is a simple configuration joining two anchors and having numerous intermediate supports. The geometric and material properties of the pipe elements are given below. Pipe outside diameter =3.5 in, Pipe wall thickness =0.216 in, Pipe density =0.403 lb/in3 Young's Modulus of Elasticity =25,800,000 psi, Poisson's Ratio =0.3 Mode number Frequency NRC Frequency TRIFLEX Difference