Sie sind auf Seite 1von 1

SECTION-III(G) TENDER NOTICE NO.

TE-655/2009-10

For the Supply Of 8.5 mtr. long Pre Stressed Concrete Pole having
working load 180Kg. conforming to IS: 1678-1998 with latest amendments

GURANTEED TECHNICAL PARTICULARS OF 8.5 MTR. LONG PCC POLES

Sno. PARTICULARS UNIT DETAILS


1 2 3 4
1. Name of the Manufactuere Anand Industrial Enterprises
(Pole Div.)
2. Overall length of the pole Mtr. 8.5
3. Depth of Plantation Mtr. 1.52
4. Minimum Ultimate Traverse Load Kg.. 450
5. Weight of the pole in Kgs Kg. 400 (approx.)
6. Factor of Safety Not less 2.5
7. Working Load applied at 300mm from top Kg. 180
8. Volume of the pole in cubic meter Cubic Mtr. 0.1702175
9. Dimensions of pole
a) Top Dimension mm 90 x 145
b) Bottom Dimension mm 90 x 300
10. Actual consumption / quantity of material used
in manufacture of each PCC POLES
i) Cement Kg. 110
ii) Aggregate 1 : 2 : 3 (Cement : Corse Sand :
Stone Chip)
iii) Sand Cft 2.85
iv) Stone Chips Cft 5.50
v) HT Steel Wire
a) Dia of Wire mm 4
b) No. of wire No. 14 (12 full + 2 half length)
c) Weight of Wire Kg. 12 / 13 (Approx.) inclusive of
wastage
vi) Other M.S. Reinforcement
a) HT wire Rings mm 4 HT Wire bar total 12 nos.
b) HT Wire Hooks Nos. 2
c) Weight of Steel Kg. 0.500 (4 mm HT wire)
11. Process adopted for compacting By shutter vibration and curing
by spray water / steam
12. Earthing arrangement in each PCC Poles
a) Length of GI Wire & SWG Mtr. 8.2
b) Weight of GI Wire Kg. 0.75
c) No. of Galvanized Bolts, with 2 nuts & 3 No. 2 (1at top & 1at bottom)
washers
13. Method of Prestrssing By tensioning of HT wire through
machine
14. Concrete mix and cube strength after
i) 72 Hours Kg./Cum^2 245
ii) 28 days Kg./Cum^2 450
15. Are these supports suitable for use at angle YES, if properly used
points where stays are needed.