Sie sind auf Seite 1von 28

1

M1

Power Supply
(10-12 Vcc)

D1
1N4001

IN

+
C1
100uF

COM

4
+5

R1

OUT

U1
7805

+5

C2
100nF

4k7

C3
100uF

R2

4k7

R3

M2

1
2
ICSP 3
4
5
6

Q3
BC327

4k7

Q2
BC327

Q1
BC327

+5
DS3

+5

+5

R10
10k

R11
10k

15

18
1
3

RA5

RB1
RB2
RB3

RA6
U2
PIC16F628A

RA1

RB7
RB6
RB5
RB4

RA2
RA0

S3

S4

S5

DL2

R12
10k

13
12
11
10

10k
R13

17

RA7

5
3
2
4

A
B
C
D

6 16
1
LD PH +V a
b
c
U3
CD4543
d
e
f
g
BL GND
8
7

9
10
11
12
13
15
14

R19
R14
R15
R16
R17
R18

a b c d e f g
7 6 4 2 1 9 10

220
220
220
220
220
220
220

R20

Al Ballast
R24
220

+5

R4

16

Q4
BC337

4k7

+1s

a b c d e f g
7 6 4 2 1 9 10

M3

1
2

Reset
D2

Start/Pause

+5
R6
4k7
16
+VCC

R22
220k

C7

Cext
U4
CD4060

10

Rext

47p
C8

R21
2M2

47p XTAL1
32,768 kHz

11

Rs
GND

Q4
Q5
Q6
Q7
Q8
Q9
Q10
Q12
Q13
Q14

7
5
4
6
14
13
15
1
2
3

Rx
BUZ1
2300 Hz@85dB
(Autoscillante)

Q5
BC337

Cop.
Chiuso

R5
4k7
K

R23
220

Valter Narcisi - San Benedetto del Tronto (AP)

Project:

Timer Bromografo con Microchip PIC16F628A

2 Hz

OFF

Size:
Note:

220 Vac

DLverde

Author:

Conteggio
ON

+5

220

DL3
Led Bicolore R-V
(Red & Green)

Reset
12

Q6
BC337

Microswitch Sicurezza Cop. Aperto


SW1

+5

OFF ON

100nF

ON/OFF

RL1
SMI-05VDC-SL-2C

C6

TP
32,768 kHz

Accensione
Neon UV-A

1N4148

+10s

GND

S2

+1m

a b c d e f g
7 6 4 2 1 9 10

100nF

7
8
9

RA4

RB0

3
8
5
AC AC DP

S1

DS1

RA3
Int.

3
8
5
AC AC DP

C5

100nF

DL1

+5

14

R9
10k

+V

R8
10k

DS2

TDSR515 x 3
Anodo Comune

C4
R7
10k

3
8
5
AC AC DP

A4

DWG no.

Rev.:

Scale:

1:1

www.narcisivalter.it - info@narcisivalter.it
4

Year:
Sheet:

2012
1 di 1

LA SEZIONE CONTROLLO

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

M1

Power Supply

D1
1N4001

IN

+
C1
100uF

OUT

U1
7805

COM

+5

C2
100nF

C3
100uF

D
M2

+5

1
2
3
ICSP
4
5
6

+5

1
2
3 M101
4
5

+5
C4

R9
10k

R10
10k

R11
10k

4
C

C5

100nF

14

R8
10k

15
18
1
3

RA5

+V

RB1
RB2
RB3

RA6
U2
PIC16F628A

RA1

RB7
RB6
RB5
RB4

RA2
RA0

+1m

S3

+10s

S4

S5

+1s

RB0

GND

S2

13
12
11
10

10k
R13

17

RA7

5
3
2
4

A
B
C
D

1
6 16
LD PH +V a
b
c
U3
CD4543
d
e
f
g
BL GND
7
8

9
10
11
12
13
15
14

1
2
3
4
M102
5
6
7
8

Al Ballast

2
+5
Accensione Neon UV-A
M3

16

1
2

S1

R12
10k

RA4
RA3

Int.

100nF

7
8
9

Reset
D2

Start/Pause

1N4148

R7
10k

+5

B
+5

100nF
16

R22
220k

C7

10

Cext

U4
CD4060

Rext

47p
C8

R21
2M2

47p XT1
32,768 kHz

11

Rs
GND
8

Q6
BC337

Rx

+VCC
9

OFF ON

Microswitch Sicurezza Cop. Aperto


SW1

+5

Q4
Q5
Q6
Q7
Q8
Q9
Q10
Q12
Q13
Q14

7
5
4
6
14
13
15
1
2
3

BUZ1
2300Hz@85dB
(Autoscillante)

Cop.
Chiuso

R5
4k7

+5

220
DLverde
220 Vac

Q5
BC337

DL3
K

Led Bicolore R-V

R23
220

2 Hz

Author:

Valter Narcisi - San Benedetto del Tronto (AP)

Project:

Timer per Bromografo - Solo sez. Controllo

Reset
12

Conteggio
ON

Size:

OFF

Note:
1

ON/OFF
Interruttore Accensione

R6
4k7

C6

TP
32,768 kHz

RL1
SMI-05VDC-SL-2C

A4

DWG no.

Rev.:

Scale:

1:1

www.narcisivalter.it - info@narcisivalter.it
4

Year:
Sheet:

2012
1 di 2

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

PCB Componenti Controllo (75x75 mm)


I 13 ponti in BLU vanno montati allinizio.
Al posto di DL3 inserire un connettore tripolare.
Per alimentazione superiore ai 10-12 Vcc, alettare U1 (7805).
Il cicalino BUZ1 del tipo autoscillante a 5 Vcc.
Il rel RL1 da 5 Vcc

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

ELENCO COMPONENTI del circuito CONTROLLO


Sigla

Valore

Library Reference Sheet

BUZ1
C1
C2
C3
C4
C5
C6
C7
C8
D1
D2
DL3
DLverde
M1
M2
M3
M101
M102
ON/OFF
Q5
Q6
R5
R6
R7
R8
R9
R10
R11
R12
R13
R21
R22
R23
Rx
RL1
S1
S2
S3
S4
S5
SW1
TP
U1
U2
U3
U4
XT1

BUZZER Autoscill.
100uF
100nF
100uF
100nF
100nF
100nF
47p
47p
1N4001
1N4148
Led Bicolore
Led Verde
Connettore 2 poli
Connettore 6 poli
Morsettiera 2 poli
Connettore 5 poli
Connettore 8 poli
Interruttore 220V
BC337
BC337
4k7
4k7
10k
10k
10k
10k
10k
10k
10k
2M2
220k
220
Res. 220 ohm
SMI-05VDC-SL-2C
Pulsante +1m
Pulsante +10s
Pulsante +1s
Puls. Start/Pause
Pulsante Reset
Microswitch Sicur.
Pin Test Poin
7805
PIC16F628A
CD4543
CD4060
Quarzo 32,768 kHz

Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.
Timer_CONTROLLO.

Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

LA SEZIONE DISPLAY

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

+5

M101

1
2
3
4
5

R1 4k7

R2 4k7
Q3
BC327

R3 4k7

Q2
BC327

Q1
BC327

+5
DS3

8
5
3
AC AC DP

DS2
DL1

8
5
3
AC AC DP

DS1

8
5
3
AC AC DP
C

K
TDSR515 x 3
Anodo Comune

DL2

K
a b c d e f g
7 6 4 2 1 9 10
R19

M102

1
2
3
4
5
6
7
8

R14
R15
R16
R17
R18

R24
220

a b c d e f g
7 6 4 2 1 9 10

220
220
220
220
220
220
220

R20

B
R4

4k7

Q4
BC337

Author:

Valter Narcisi - San Benedetto del Tronto (AP)

Project:

Timer per Bromografo - Solo sez. Display

Size:
Note:
1

a b c d e f g
7 6 4 2 1 9 10

DWG no.

Rev.:

Scale:

Year:
Sheet:

1:1

www.narcisivalter.it - info@narcisivalter.it
3

2012
2 di 2

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

PCB Componenti Display (75x60 mm)


I ponti in ROSSO vanno montati sotto i display; in BLU gli altri 7 ponti.
DL1 e DL2 vanno leggermente limati alla base

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

ELENCO COMPONENTI del circuito DISPLAY


Sigla

Valore

Library Reference Sheet

DL1
DL2
DS1
DS2
DS3
M101
M102
Q1
Q2
Q3
Q4
R1
R2
R3
R4
R14
R15
R16
R17
R18
R19
R20
R24

LED Rosso 3,5 mm


LED Rosso 3,5 mm
TDSR515 display
TDSR515 display
TDSR515 display
Connettore 5 poli
Connettore 8 poli
BC327
BC327
BC327
BC337
4k7
4k7
4k7
4k7
220
220
220
220
220
220
220
220

Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.
Timer_DISPLAY.

Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic
Schematic

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

COME REALIZZARE LA SCHEDA PULSANTI


CON UNA MILLEFORI
Non ho realizzato un PCB dei comandi perch chi realizzer questo bromografo
pu avere diverse soluzioni e motare pulsanti e LEDs a proprio gusto
(ad esempio, utilizzando il vecchio contenitore di uno scanner oppure un diverso
tipo di pulsanti).
La scheda che ospita i pulsanti ed il LED, quindi, dovr essere realizzata a seconda
delle proprie esigenze.
In queste righe illustro come ho realizzato la mia utilizzando una semplice millefori.
Ritagliare un pezzo prendendo come riferimento 27 fori in larghezza
e 14 in altezza. Evitare possibilmente i bordi visto che da piastra a piastra
potrebbero esserci piccole ma sostanziali differenze.
Una volta tagliata la piastra (ricordo, lungo il 27esimo foro in larghezza e lungo
il 14esimo foro in altezza), si avr un PCB con le misure di circa 66 x 33 mm.
Fate i due fori per il fissaggio della scheda allargando due di quelli gi esistenti,
come visibile nel disegno: quindi inserite i pulsanti tutti nello stesso verso.
Chi realizzer il bromografo del sottoscritto, noter che la larghezza massima del
vano cavi di 77 mm per cui le schede non dovranno mai superare questa misura.

27 FORI

Ritagliare questo pezzo


da una millefori

14 FORI

33,0 mm (14 fori)

66,0 mm (27 fori)

Allargare i due fori fino al diametro di 3 mm,


serviranno per il fissaggio della scheda.
Quindi inserire i pulsanti come in figura
e saldarli.
Nel posto riservato al pulsante mancante,
andr inserito e saldato il LED bicolore.
2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

FOTO DEI CIRCUITI STAMPATI

Alimentazione: da 8 Vcc a 12 Vcc


Assorbimento: circa 80-90 mA in Stand-By e 180-200 mA in fase di conteggio.
2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

LA REALIZZAZIONE DEL PANNELLINO COMANDI

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

LA REALIZZAZIONE DEL PANNELLINO COMANDI

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

LA REALIZZAZIONE DEL PANNELLINO COMANDI

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

SERIGRAFIA

PROGRAMMING
+1 Min.

+10 Sec.

+1 Sec.

UV-A
neon

Start/Pause

Reset

COMMANDS

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

LA REALIZZAZIONE DEL COPERCHIO VANO CAVI


VISTA FRONTALE

VISTA SEZIONE

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

LA REALIZZAZIONE DEL COPERCHIO VANO CAVI

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

MONTAGGIO ULTIMATO DEL COPERCHIO VANO CAVI

AVANTI

SEZIONE

9,2 mm
Distanziatore
Scheda
Display

85 mm

3,5 mm
Spessore
Pannello

285 mm

9 8

67 mm

116 mm

130 mm

116 mm

14
mm

10 8

33 mm

102 mm

8
10,5 mm
Distanziatore
Scheda
Pulsanti

18 mm

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html

IL FUNZIONAMENTO DEL BROMOGRAFO con TIMER


Il funzionamento del Timer (e dell'intero bromografo) semplicissimo.
Dopo l'accensione, il bromografo emette un beep di mezzo secondo, il LED UV-A neon sul
pannellino si accende di colore verde e il display visualizza 0:00.

Per impostare i MINUTI, premere una o pi volte il pulsante +1 Min. (quando il display
visualizzer la cifra 9, la successiva pressione del pulsante far apparire nuovamente uno 0 e cos via).
Per impostare le DECINE dei SECONDI, premere una o pi volte il pulsante +10
Sec. (quando il display visualizzer la cifra 5, la successiva pressione del pulsante far apparire
nuovamente uno 0 e cos via).

Per impostare le i SECONDI, premere una o pi volte il pulsante +1 Sec. (quando il

display visualizzer la cifra 9, la successiva pressione del pulsante far apparire nuovamente uno 0 e cos
via).

Una volta effrttuata la programmazione (e controllato che il LED DLverde, se installato, sia
regolarmente acceso) possibile avviare il conteggio premendo il pulsante Start/Pause: il
LED UV-A neon diventa rosso e il valore sul display comincer a decrementarsi (questa la fase

di count-down, scandita anche dal caratteristico "toc" emesso dal cicalino ad ogni decremento di cifra, o, se
vogliamo, ad ogni secondo).

Una volta terminato il conteggio, i neon UV-A si spengono, sul display appare nuovamente il
valore 0:00, il LED UV-A neon torner nuovamente verde ed il cicalino emette 3 beep ad
indicare il fine conteggio (Con il firmware 2.0, a fine conteggio appare di nuovo il tempo programmato).
Durante il count-down possibile spegnere momentaneamente i neon UV-A premendo il
pulsante Start/Pause: in tal caso il bromografo rimane in attesa mentre il display visualizza il
tempo rimanente. Durante questa fase di PAUSA possibile "correggere" la programmazione
agendo sui pulsanti dei MINUTI e dei SECONDI per variare il tempo rimasto.
Premere nuovamente il pulsante Start/Pause per far riprende il count-down da dove era
stato fermato (o, eventualmente, dal nuovo valore programmato durante la PAUSA).
Se durante il conteggio si apre il coperchio del vano neon, i neon stessi si spengono ed
il conteggio si ferma momentaneamente in attesa di riprenderlo automaticamente alla chiusura
del coperchio: quando, come in questo caso, lo spegnimento dei neon causato dall'apertura
del coperchio (accidentale o meno), possibile fare solo due operazioni:

premere il pulsante Reset e cancellare la programmazione (e quindi ripristinare il


bromografo nello stato iniziale, come subito dopo l'accensione)
premere il pulsante Start/Pause per entrare in PAUSA ed effettuare, eventualmente,
le modifiche alla programmazione. Va da se che fino a quando non si chiude il coperchio, non ci
sar nessuna ripresa del conteggio.

Il pulsante Reset sempre attivo ed in ogni caso la sua pressione provoca un reset
generale del bromografo, riportandolo nello stato iniziale di stand-by e azzerando il display.
Per effettuare il TEST del Display (cio per controllarne che tutti i segmenti funzionino alla
perfezione) sufficiente premere il pulsante Start/Pause quando il display segna il
valore 0:00: in tal modo saranno visualizzati in sequenza, per un secondo, le tre cifre del
display con tutti i segmenti accesi (Con il firmware 2.0, il Test si avvia anche all'accensione).
La pressione di uno qualsiasi dei pulsanti provoca un brevissimo beep del cicalino tranne che
per il pulsante Reset, la cui pressione provoca sempre l'emissione di un beep di mezzo
secondo.
(NB - Nella versione firmware 2.0, il tempo programmato rimane in memoria anche quando si spegne il bromografo)

2012 by Valter Narcisi info@narcisivalter.it http://www.narcisivalter.it/progetti/bromografo-con-timer_2p.html