Foundation Schedule

F1: 1100 X 1100 X 350, 8 - 16 both ways (Bottom Bars)


F2: 1100 X 1100 X 350, 8 - 16 both ways (Top & Bottom Bars)
Column Schedule
C1: 200 X 400: 6 16 vertical bars; 10-mm ties: 1 @ 50, 4 @ 100, rest @ 200 o.c. to midheight
C2: 200 X 400: 8 16 vertical bars; 10-mm ties: 1 @ 50, 4 @ 100, rest @ 200 o.c. to midheight
Beam Schedule
B1: 200 X 300, 3 16 @ supports (Top & Bottom), 2 16 @ midspan (Top & Bottom); 1 @ 50, 4 @ 100, rest @ 150 o.c. to midspan
TB1: 250 X 400, 3 16 @ supports (Top & Bottom), 2 16 @ midspan (Top & Bottom); 1 @ 50, 4 @ 100, rest @ 200 o.c. to midspan
Floor Slab
100-mm slab; 10-mm bottom bars @ 150 mm o.c. both ways
C-Purlins on Roof
Cold-formed 100 x 50 x 12 x 2 @ 750 mm o.c. (sagrod is optional)
Box-Type Tubular Purlins on Garage roof
Cold-formed 100 x 50 x 5 @ 500 mm o.c.
Wall footings
WF1a & WF1b: Long Direction: 3 16; Short Direction: 10 @ 200 o.c.
WF2: 3 12 Bottom Bars; 12 @ 300 extra bottom bars

CHB

CHB

CHB

400

400

400

400

600

WF1a

WF1b

Extra bottom bars

400

400
WF2

FFL