Beruflich Dokumente
Kultur Dokumente
ID Fan
100 % MCR Test Block
Flow
m3/s
39.53
49.41
Head
mmWC
244
227
Oper.Temp
Deg c
140
140
Efficiency
%
71
78.5
Motor Rating KW
160
Motor speed RPM
980
Fan Details
FD Fan
100 % MCR Test Block
Flow
m3/s
28.24
35.3
Head
mmWC
941
815
Oper.Temp
Deg c
40
40
Efficiency
%
80.5
82
Motor Rating KW
380
Motor speed RPM
1480
Fan Details
PA Fan
100 % MCR Test Block
Flow
m3/s
4.46
5.57
Head
mmWC
850
800
Oper.Temp
Deg c
165
165
Efficiency
%
76
80
Motor Rating KW
75
Motor speed RPM
1480
mm
43.5 X 10
mm
119 X 10
5 compartments
4 PA Lines / compartments
Total
20 Lines
Kcal / Hr
Kcal / Hr
65960652
64403673
Kcal / Kg
Kcal / Kg
Kcal / Kg
6000
4115
3600
TPH
TPH
10.993442
15.6509533
mm
<6
Performance Fuel
Imported Coal
Indian Coal
Worst Coal
Fuel Consumption
Imported Coal
Indian Coal
Coal Size
LOGSHEET :
Date : 23/04/2010
12:15
12:45
TPH
91.1
92.5
Deg C
523
527
Kg/cm2
82.3
82.4
Deg C
170
171
Deg C
274
272
TPH
117
114
TPH
1226
1223
UNITS
PA Header Pressure
mmWC
Deg C
135
135
Deg C
--
--
Deg C
211
210
Deg C
128
128
PA Header Temperature
Deg C
135
135
mmWC
657
661
29.8
29.7
3.5
KW
65.7827456
66.415272
Volts
415
415
Amps
104
105
P.F
0.88
0.88
Bed DP
mmWC
570
580
mmWC
605
611
mmWC
--
--
TPH
--
--
Kcal / Kg
3154
3154
Coal flow
GCV of Coal
430 / 410 /
505 / 550 /
530
Same
KG/m3
---
---
Length
mm
---
---
Width
mm
---
---
Height
mm
---
---
OD X Thick./ ID
119 X 10
119 X 10
No's
20
20
No's
20
20
Feeder RPM
Coal Density
Feeder Dimension
mmWC
Flow
Total Air flow
Air Flow Per Line
TPH
TPH
TPH
450
18.75
0.9375
%
%
1.45123839
4.204035874
PA Fan Details
100 % MCR
m3/s
4.46
m3 / Hr
m3 / Hr
16.056
0.223
Approximate
Calculation
Test Block
5.57