Sie sind auf Seite 1von 3

EGO:;

PAGE

PRESET
PARAMETER
VALUE
VALUE MODIFIABLE
-----------------------------------------------------------------------------T4
60.00 S
60.00 S
YES
T7
20.00 S
20.00 S
YES
T8
12.00 S
12.00 S
YES
T10
22.00 S
8.00 S
YES
T13
15.00 S
15.00 S
YES
T17
4.00 S
4.00 S
YES
T18
12.00 S
12.00 S
YES
T25
20.00 S
20.00 S
YES
T3101
5.00 S
3.00 S
YES
T3103
20.00 S
6.00 S
YES
T3105_D
0.28 S
0.28 S
NO
T3105_F
0.10 S
0.10 S
NO
T3107
20.00 S
6.00 S
YES
T3109
15.00 S
12.00 S
YES
T3111
0.50 S
0.50 S
NO
T3111_DTM
0.30 S
0.30 S
YES
T3121
12.00 S
12.00 S
YES
T3122
6.00 S
6.00 S
YES
T3168
1.00 S
1.00 S
YES
PAGE

PRESET
PARAMETER
VALUE
VALUE MODIFIABLE
-----------------------------------------------------------------------------T3192
0.50 S
0.50 S
YES
T3192_SAT
1.50 S
1.50 S
YES
T9101
10.00 S
10.00 S
NO
T9103
2.00 S
2.00 S
NO
T9104
15.00 S
15.00 S
YES
T9105
10.00 S
10.00 S
YES
T9108
2.00 S
2.00 S
NO
T9113
15.00 S
13.00 S
YES
TBBI
15.00 S
15.00 S
YES
CSDAP
90.00 S
90.00 S
YES
CELL IDENTIFIER
LAC+CI
LAC+CI
YES
BLOCK MSG INCOMING GLOBAL RESET
YES
YES
YES
BLOCK MSG OUTGOING GLOBAL RESET
YES
YES
YES
UNBLOCK MSG IN GLOBAL RESET
NO
NO
YES
SEND SYS INFO GLOBAL RESET
YES
YES
YES
CELL BARRING INCOMING GLOBAL RESET
NO
NO
YES
ALLOW SENDING OF CONFUSION MESSAGES
NO
NO
YES
ALLOW CIRCUIT GROUP MESSAGES
NO
NO
YES
ALARM LIMIT FOR UNAVAILABLE A-IF CIRCUITS
100 %
100 %
YES
PAGE

PRESET
PARAMETER
VALUE
VALUE MODIFIABLE
-----------------------------------------------------------------------------ALARM DELAY FOR UNAVAILABLE A-IF CIRCUITS
60 S
60 S
YES
ALARM LIMIT FOR SUCCESSIVE REMOTE TC FAIL
3
3
YES
ALLOW SENDING OF UNEQUIPPED CIRCUIT MESSAGES
NO
NO
YES
ALLOW SENDING OF TA VALUE TO MSC
0
0
YES
PREFERENCE PROCEDURE IN CONFLICT SITUATION
ASSIGN
ASSIGN YES

BS_CV_MAX
DECREMENT VALUE FOR COUNTER N3102
INCREMENT VALUE FOR COUNTER N3102
MAXIMUM VALUE FOR COUNTER N3102
DOWNLINK DTX
NMO - NETWORK MODE OF OPERATION
REPEAT COUNT FOR ALARM 3121
FEP CORR WITH RXQUAL IN PC&HO ALGRTHM
FEP CORR WITH RXQUAL IN PC&HO ALGRTHM
FEP CORR WITH RXQUAL IN PC&HO ALGRTHM
FEP CORR WITH RXQUAL IN PC&HO ALGRTHM
FEP CORR WITH RXQUAL IN PC&HO ALGRTHM
FEP CORR WITH RXQUAL IN PC&HO ALGRTHM
FEP CORR WITH RXQUAL IN PC&HO ALGRTHM
PAGE

CL1
CL2
CL3
CL4
CL5
CL6
CL7

9
1
1
1
YES
01
10
2
4
6
8
10
12
14

BIN
%
%
%
%
%
%
%

9
1
1
1
NO
01
10
2
4
6
8
10
12
14

YES
YES
YES
YES
YES
BIN YES
YES
%
YES
%
YES
%
YES
%
YES
%
YES
%
YES
%
YES

PRESET
PARAMETER
VALUE
VALUE MODIFIABLE
-----------------------------------------------------------------------------SGSN RELEASE
1
1
YES
MSC RELEASE
1
1
YES
DRX TIMER MAX
3
3
YES
TWO-WAY SPEECH PATH CONNECT TRIGGER POINT
0
0
YES
BS_CV_MAX_SAT
15
15
YES
REPEAT COUNT FOR INTERNAL HO REQUIRED
2
2
YES
CSDAP_THR
5
5
YES
COMMAND EXECUTED
GSM TIMER AND BSC PARAMETERS HANDLING COMMAND <EG_>
INTERROGATING SCCP SIGNALLING POINT PARAMETER SETS
SET NUMBER: 00001
SET NAME: A-INT
========================================================================
NO: NAME
VALUE
UNIT
--- ------------------------------ -----1 Q714_T_CONN_EST
90 1 S
2 Q714_T_IAS
120 1 S
3 Q714_T_IAR
660 1 S
4 Q714_T_REL
150 0.1 S
5 Q714_T_INT
60 1 S
6 Q714_T_RES
15 1 S
7 Q714_T_REP_REL
100 0.1 S
8 Q714_T_STAT_1ST
100 0.1 S
9 Q714_T_STAT_INC
300 0.1 S
10 Q714_T_STAT_MAX
9000 0.1 S
11 A_INTERFACE
YES
12 WHITE_BOOK_MGMT_USED
NO
13 SS_MANAGEMENT_USED
YES
14 XUDT_USED
NO
15 UDT_DENIED
NO
16 SEG_X_THRES
272 OCTETS
17 SEG_Y_THRES
272 OCTETS
18 TCAP_LOAD_SHARING_USED
NO
19 ADD_DPC_IF_RI_SSN
NO
20 ADD_GT_IF_RI_SSN
NO
21 ADD_DPC_IF_RI_GT
NO
22 ANALYSE_ROOT_OF_CALLING_GT
NO
23 ALLOWED_GTI_VALUES
1-4,5,6,7,8,9,10,11,
-

12,13,14,15
24
25
26
27
28

SSA_FILTER_TIMER
SSP_FILTER_TIMER
LUDT_USED
CO_SEGM_USED
GT_ADDR_FIXED_LEN

COMMAND EXECUTED

10
10
NO
NO
NO

0.1 S
0.1 S
-