CALCULATION CHECK FOR SHEAR & STABILITY OF PANELS - VS1-ILP-19 & 19X:

Design Forces: Pu =

Given:

203.00 kN. Wp =

51.00

kN.
61.20

Wpu = 1.2* Wp =

kN.

Check for Panel Stability:


M@Pt.'x' = 0 ]
Overturning Moment, OM:
49.1
OM = Pu*0.242 =

kN-m.

Resisting Moment, RM:


RM = Wpu*1.354 = 82.9

kN-m.

Factor of Safety, FS:


1.7

FS = OM / RM =

> 1.5

Hence, OK!

Check for Beam Shear:


* Considering potential crack line w/

eff. Depth,deff=1100+1120=2220mm
Net thickness, tn = 150 - 70 = 80mm
fc' = 32 Mpa. ; fy = 420 Mpa
*Mesh - T8@200c/c, As = 252mm2 /m
Concrete Shear Capacity, Vc:
Vc = 0.75 * fc^0.5 * tn * deff
(LOWER PANEL)

Vc =

125.6

kN.

Steel Shear Capacity, Vs:


Vs = 0.75 * 0.6 * fy * As * deff
Vs =

105.7

kN.

Total Shear Capacity, Vt:


Vt = Vc + Vs = 231.3
kN.

< Pu = 203 kN.


Hence, OK!