Sie sind auf Seite 1von 8

CALCULO DEL NUMERO DE LOTES

MANZANA
A
B
C
D
E
F
G
H
I

LOTE/MANZANA
10
9
9
11
7
8
8
18
18

# MANZANA

LOTES

1
1
1
1
1
1
1
1
1
LOTES TOTALES

10
9
9
11
7
8
8
18
18
98

densidad=

2000 l/conex/dia
250.00 l/hab/dia

CALCULO DE LA DENSIDAD
consumo = dotacion
dotacion=
consumo=
consumo=
consumo=

250.00 l/hab/dia
60.00 m3/conex/mes
60000.00 l/conex/mes
2000.00 l/conex/dia

densidad= 8.00 Hab/Conexion

CALCULO DE LA POBLACION INICIAL, CAUDAL PROMEDIO Y CAUDAL MAXIMO HORARIO


P0= 784 HAB
TASA DE CRECIMIENTO= 0.009
F.R= 0.80
K2= 1.96

AO

POBLACION
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

784
792
799
806
813
820
828
835
843
850
858
866
873
881
889
897
905
913
922
930
938

DENSIDAD
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion
8.00 Hab/Conexion

# LOTES
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118

DOTACION
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia
250.00 l/hab/dia

CONSUMO
CONSUMO
PROMEDIO
MAX HOR
POR AO
2.27 l/s
4.446 l/s
2.29 l/s
4.49 l/s
2.31 l/s
4.53 l/s
2.33 l/s
4.57 l/s
2.35 l/s
4.61 l/s
2.37 l/s
4.65 l/s
2.40 l/s
4.70 l/s
2.42 l/s
4.74 l/s
2.44 l/s
4.78 l/s
2.46 l/s
4.82 l/s
2.48 l/s
4.87 l/s
2.51 l/s
4.91 l/s
2.53 l/s
4.95 l/s
2.55 l/s
5.00 l/s
2.57 l/s
5.04 l/s
2.60 l/s
5.09 l/s
2.62 l/s
5.13 l/s
2.64 l/s
5.18 l/s
2.67 l/s
5.23 l/s
2.69 l/s
5.27 l/s
2.71 l/s
5.32 l/s

DESAGUE
SUJETO DE
CONSUMO
(DOMESTICO)
3.56 l/s
3.59 l/s
3.63 l/s
3.66 l/s
3.69 l/s
3.72 l/s
3.76 l/s
3.79 l/s
3.82 l/s
3.86 l/s
3.89 l/s
3.93 l/s
3.96 l/s
4.00 l/s
4.03 l/s
4.07 l/s
4.11 l/s
4.14 l/s
4.18 l/s
4.22 l/s
4.25574 l/s

CALCULO DEL CAUDAL DE DISEO


CONEXIN EQUIVALENTE POR LOTE =
CAUDAL POR CONEXIN AL AO 20 =
TRAMO
BZ

N CONEXIONES
AO "0"

BZ
1
2
3
4
5
1
7
8
9
2
6

2
3
4
5
6
7
8
9
6
7

9
15
0
14
17
11
11
0
13
8

DESCARGA
CONEXIOMES=

98

SIFON
SIFON 01
SIFON 02

Q MAX
m3/s
0.00256
0.13120

1.204081633
0.04343 L/S
N CONEXIONES
AO "20"
11
18
0
17
20
13
13
0
16
10
0
118

Q PROM
m3/s
0.00120
0.10757

intensidad= 85.00 l/s/ha


0.43
AREA DE INFLUENCIA= 32408.18 m2 = 3.24 Ha

coeficiente de impermeabilidad=

CI= 20000.00 L/KM/DIA =


SUJETO DE CONSUMO
DOMESTICO INSDUSTRIAL
0.39083 L/S
0.65139 L/S
0.00000 L/S
0.60796 L/S
0.73824 L/S
0.47769 L/S
0.47769 L/S
70 L/S
0.00000 L/S
0.56454 L/S
0.34741 L/S
0.00000 L/S
4.25574 L/S

Q MIN
m3/s
0.00067
0.08891

LONGITUD
(m)
76.44
70.29
17.25
68.80
69.23
95.570
65.117
30.000
63.625
69.142
21.370

0.23148 L/KM/SEG
COEFICIENTE DE
INFILTRACION
0.000231 l/seg/m
0.000231 l/seg/m
0.000231 l/seg/m
0.000231 l/seg/m
0.000231 l/seg/m
0.000231 l/seg/m
0.000231 l/seg/m
0.000231 l/seg/m
0.000231 l/seg/m
0.000231 l/seg/m
0.000231 l/seg/m

CAUDAL DE
INFILTRACION
0.01769 L/S
0.01627 L/S
0.00399 L/S
0.01593 L/S
0.01603 L/S
0.02212 L/S
0.01507 L/S
0.00694 L/S
0.01473 L/S
0.01601 L/S
0.00495 L/S
0.14973 L/S

2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%

0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43

85.00 l/s/ha
85.00 l/s/ha
85.00 l/s/ha
85.00 l/s/ha
85.00 l/s/ha
85.00 l/s/ha
85.00 l/s/ha
85.00 l/s/ha
85.00 l/s/ha
85.00 l/s/ha
85.00 l/s/ha

A
3293.2898
4086.6558
1206.3648
4215.9197
3353.4180
4034.566
3639.829
1891.2441
3292.7084
2018.3149
1375.8681
32408.18

CAUDAL DE
COEXIONES ERRADAS
0.24074 L/S
0.29873 L/S
0.08819 L/S
0.30818 L/S
0.24513 L/S
0.29493 L/S
0.26607 L/S
0.13825 L/S
0.24070 L/S
0.14754 L/S
0.10058 L/S
2.36904 L/S

CAUDAL DE DISEO
0.649 L/S
0.966 L/S
0.092 L/S
0.932 L/S
0.999 L/S
0.795 L/S
70.759 L/S
0.145 L/S
0.820 L/S
0.511 L/S
0.106 L/S
76.77451 L/S

CALCULO HIDRULICO PARA EL SISTEMA DE ALCANTARILLADO SANITARIO POR EL CRITERIO DE TENSIN TRACT
Proyecto: SOLUCIONARIO DE PTRACTICA CALIFICADA N01
sMin=1.00 Pa
3

COLECTOR
CONTRIBUYENTE

m /s

Q. de
Aguas
Arriba
(m3/s)

10

11

Q.
Del
Tramo
(m3/s)

Q. de
Aguas
Abajo
(m3/s)

12

Descarga
en el
Colector
N

1
1
1
1
1
1
2
2
2
2
3

VI
V
IV
III
II
I
IV
III
II
I
I

1
2
3
4
5
6
1
7
8
9
2

2
3
4
5
6
Des
7
8
9
6
7

76.44
70.29
17.25
68.80
69.23
21.37
95.57
65.12
30.00
63.63
69.14

0.0000
0.0000
0.0000
0.0000
0.0000
0.1320
0.0580
0.0015
0.0000
0.0000
0.0000

0.00
0.00150
0.00247
0.00256
0.00349
0.00449
0.00000
0.05879
0.13105
0.13120
0.0000

0.0015
0.000966
0.000092
0.000932
0.000999
0.000106
0.000795
0.070759
0.000145
0.000820
0.0015

0.00150
0.00247
0.00256
0.00349
0.00449
0.13661
0.05879
0.13105
0.13120
0.13202
0.00150

1
1
1
1
1

V
IV
III
II
I

2
2
2
1
2

83.50

0.0000

0.0000

0.0580

0.05800

Nombre

Abajo

Arriba

N
DE BUZON

Tramo

VMax= 5 m/s

Colector

DMin= 200 mm

Long.
(m)

13

14

Cota de Terreno

y/D Max=
15

16

Profundidad

17

18

0.75

19

20

23

24

Dh
(m)

S
(m/m)

D Teo
(mm)

25

26

27

28

29

30

A0

V0
(m/s)

P0
(m)

R0
(m)

Cota de Fondo

A. Arriba A. Abajo A. Arriba A. Abajo A. Arriba A. Abajo


(m)
(m)
(m)
(m)
(m)
(m)

Q0
D Com
(mm) (m3/s)

(m2)

185.50
184.10
184.00
184.15
183.70
184.00
185.80
184.20
184.10
183.70
185.80

1.00
2.00
1.20
1.80
2.65
2.45
1.50
2.70
1.35
1.62
1.00

2.00
1.20
1.80
2.65
2.45
2.85
2.70
1.35
1.62
1.45
1.70

184.00
183.50
182.90
182.20
181.50
181.25
183.50
183.10
182.85
182.48
184.50

183.50
182.90
182.20
181.50
181.25
181.15
183.10
182.85
182.48
182.25
184.1

0.50
0.60
0.70
0.70
0.25
0.10
0.40
0.25
0.37
0.23
0.40

0.0065
0.0085
0.0406
0.0102
0.0036
0.0047
0.0042
0.0038
0.0125
0.0036
0.0058

0.009
0.009
0.009
0.009
0.009
0.009
0.009
0.009
0.009
0.009
0.009

59
68

200
200

0.0384 0.0314 1.2209 0.6283 0.0500


0.0438 0.0314 1.3947 0.6283 0.0500

III
II
I
I
III

185.00
185.50
184.10
184.00
184.15
183.70
185.00
185.80
184.20
184.10
185.50

75
100
342
254
349

200
200
400
315
400

0.0479
0.028
0.206
0.103
0.187

0.0314
0.031
0.126
0.078
0.126

1.5232
0.907
1.639
1.322
1.485

0.6283 0.0500
0.628 0.05
1.257
0.1
0.99 0.079
1.257
0.1

355
60

400
200

0.18
0.036

0.126
0.031

1.429
1.148

1.257
0.628

0.1
0.05

2 IV

184.80

185.00

1.20

1.50

183.60

183.5

0.10

0.0012

0.009

320

355

0.076

0.099

0.766

1.115

0.089

RITERIO DE TENSIN TRACTIVA MEDIA

31

32

33

34

35

36

37

38

39

40

y
(m)

y/D

Vf
(m/s)

s
(Pa)

RH
(m)

VCritica
(m/s)

TABLA

Qr/Q0

Vr/V0

Condiciones para que el calculo Hidraulico sea CORRECTO

yr/D0

Rr/R0

Verificacion de Verificacion de Verificacion de Verificacion de


Vf < 5.0
D>160mm
y < 0.75D
s>1.0Pa

Analisis de la "y" cuando


Vf > VCritica

0.04
0.06

0.4270 0.1650 0.4100


0.4730 0.1960 0.4810

0.033
0.039

0.16500
0.19600

0.521
0.66

1.315 0.021
2.014 0.024

2.69
2.91

Correcto
Correcto

Correcto
Correcto

Correcto
Correcto

Correcto
Correcto

No Analizar y
No Analizar y

0.07
0.16
0.66
0.57
0.70

0.492
0.613
0.927
0.885
0.945

0.21
0.308
0.666
0.608
0.692

0.51
0.704
1.16
1.125
1.175

0.042
0.0616
0.2664
0.1915
0.2768

0.21000
0.308
0.666
0.608
0.692

0.749
0.556
1.52
1.17
1.403

2.547 0.026 3.00


1.247 0.04 3.526
5.325 0.12 6.401
3.638 0.09 5.594
4.425 0.12 6.442

Correcto
Correcto
Correcto
Correcto
Correcto

Correcto
Correcto
Correcto
Correcto
Correcto

Correcto
Correcto
Correcto
Correcto
Correcto

Correcto
Correcto
Correcto
Correcto
Correcto

No Analizar y
No Analizar y
No Analizar y
No Analizar y
No Analizar y

0.74
0.04

0.961
0.427

0.719
0.165

1.188
0.41

0.2876
0.033

0.719
0.165

1.373
0.49

4.145
1.163

0.12
0.02

6.477
2.691

Correcto
Correcto

Correcto
Correcto

Correcto
Correcto

Correcto
Correcto

No Analizar y
No Analizar y

0.77

0.972

0.738

1.195

0.262

0.738

0.744

1.246

0.11

6.12

Correcto

Correcto

Correcto

Correcto

No Analizar y

D Com
(mm)

Q0

A0

V0
(m/s)

P0
(m)

R0
(m)

10

11

12

13

14

15

16

17

18

19

y
(m)

y/D

Vf
(m/s)

E
(m)

RH
(m)

VCritica
(m/s)

TABLA
CAUDAL
(m3/s)

SIFON

CAUDAL MAXIMO
CAUDAL PROMEDIO
CAUDAL MINIMO

0.00256
0.00120
0.00067

200
200
200

(m /s)

(m )

Qr/Q0

Vr/V0

yr/D0

Rr/R0

0.0438 0.0314 1.3947 0.6283 0.0500 0.06 0.4730 0.1960 0.4810 0.039 0.19600 0.660
0.0438 0.0314 1.3947 0.6283 0.0500 0.03 0.4000 0.1480 0.3700 0.030 0.14800 0.558
0.0438 0.0314 1.3947 0.6283 0.0500 0.02 0.3620 0.1240 0.3150 0.025 0.12400 0.505

0.061 0.024
0.045 0.019
0.038 0.016

2.91
2.56
2.36

Q1= 0.00067
Q2= 0.00053
Q3= 0.00136
1

SIFON

10

V
(m/s)

D Teo
(m)

D Com
(m)

Vf
(m/s)

L
(m)

hi
(m)

Q1= 0.00067
Q2= 0.00053

1.20

0.027

0.032

0.83

0.009

18.26

0.70

1.20

0.024

0.032

0.66

0.009

18.26

0.45

25mm

Q3= 0.00136

1.20

0.038

0.050

0.69

0.009

18.26

0.29

32 mm

40 mm
50 mm
63 mm
75 mm
90 mm
110 mm

1 1/4
1 1/2
2
2 1/2
3
4

CAUDAL
(m3/s)

0.70
cota de batea entrada 182.70
cota de bateasalida 182.00

EQUIVALENCIAS DE
EN mm. A PULGADAS
20 mm
1/2
3/4

D Com
(mm)

Q0

A0

V0
(m/s)

P0
(m)

R0
(m)

10

11

12

13

14

15

16

17

18

19

y
(m)

y/D

Vf
(m/s)

E
(m)

RH
(m)

VCritica
(m/s)

TABLA
CAUDAL
(m3/s)

SIFON

CAUDAL MAXIMO
CAUDAL PROMEDIO
CAUDAL MINIMO

0.13120
0.10757
0.08891

400
400
400

(m /s)

(m )

Qr/Q0

Vr/V0

CAUDAL
(m3/s)

Q1= 0.08891
Q2= 0.01866
Q3= 0.02363

10

V
(m/s)

D Teo
(m)

D Com
(m)

Vf
(m/s)

L
(m)

hi
(m)

1.20

0.31

0.315

1.14

0.009 29.348

0.22

1.20

0.14

0.160

0.93

0.009 29.348

0.23

1.20

0.16

0.160

1.18

0.009 29.348

0.37

0.37
cota de batea entrada 182.45
cota de bateasalida 182.08

Rr/R0

0.1866 0.1257 1.4847 1.2566 0.1000 0.70


0.98
0.75
1.2
0.300 0.75000 1.455
0.1866 0.1257 1.4847 1.2566 0.1000 0.58 0.9180 0.6510 1.1510 0.260 0.65100 1.363
0.1866 0.1257 1.4847 1.2566 0.1000 0.48 0.8650 0.5820 1.1000 0.233 0.58200 1.284

Q1= 0.089
Q2= 0.019
Q3= 0.024

SIFON

yr/D0

0.408 0.120
0.355 0.115
0.317 0.110

6.51
6.38
6.23

Das könnte Ihnen auch gefallen