Power house intersected by a fault

The figure shows the slip on the fault.


In this example the powerhouse is constructed with FF (fictitious force) elements and the fault is
constructed with DD (displacement discontinuity) elements. The DD elements are filled with an
elasto-plastic gouge material that yields according to the frictional strength Mohr-Coulomb
criterion.
838 surfaces were used to describe this problem. Map3D subsequently discretized the model
into 5236 boundary elements.
Dow nload example (ex3-t10.zip 361 KB)

ex3-t10.zip contains the analysis results pictured above.

1. Unzip ex3-t10.zip to create ex3-t10.001


2. To display these results in Map3D, use File > Open Analysis Results and select ex3t10.001

3. To display the ride on the fault use Plot > Surface Components > Ride.
4. To display the stress distribution around the powerhouse use Plot > Stress > Major
Principal Stress.