ELECTRICAL ABBREVIATIONS

ELECTRICAL SYMBOLS LEGEND


LIGHTING

lSI

FLUORESCENT FIXTURE, RECESSED

POWER
::@

..

+4tS

FLUORESCENT FIXTURE, SURFACE MOUNTED

SURFACE, PENDANT OR OTHER FIXTURE

DUPLEX RECEPTACLE, 15A 125V 2P 3W, GROUNDING TYPE,


MOUNTING HEIGHT: +18" AFF UON

DENOTES HEIGHT IN INCHES


AFF (INTERIOR) AFG (EXTERIOR)

RECESSED DOWN LIGHT FIXTURE


RECESSED DIRECTIONAL FIXTURE (ARROW INDICATES AIMING)

_{l_
::@
41>c

SINGLE RECEPTACLE, 20A 125V 2P 3W, GROUNDING TYPE,


MOUNTING HEIGHT: +18" AFF UON

(!)

SPECIAL PURPOSE RECEPTACLE AS DESIGNATED


SEE 'SPECIAL SYMBOLS' ON EACH SHEET

LIGHT TRACK AND TRACK-MOUNTED FIXTURES

DUAL SERVICE RECESSED FLOOR BOX WITH DUPLEX AND DATA


RECEPTACLES

Q)

EXIT SIGN, DOUBLE FACE WITH DIRECTIONAL ARROWS AS


INDICATED

DATA OUTLET- MOUNTING HEIGHT: +18" AFF UON

r
l

TELEPHONE/DATA OUTLET, FLUSH TYPE UON


MOUNTING HEIGHT: +18" AFF UON
DENOTES # OF
DATA JACKS

<jP. ~
-II -'fl-

SURFACE RACEWAY WITH POWER AND TELEPHONE/DATA


RECEPTACLES AS INDICATED

OR Q]

EMERGENCY FIXTURE
MOUNTING HEIGHT: +8'-0" AFF, UON

o-0---

OUTDOOR SITE LIGHT, POLE MOUNTED LUMINAIRE ARROW


INDICATES AIMING DIRECTION, IF APPLICABLE

CATV

CABLE TELEVISION
CONDUIT
CIRCUIT BREAKER
CLOSED CIRCUIT TELEVISION
CONDUIT ONLY
CONTROL POWER
TRANSFORMER
CURRENT TRANSFORMER
COPPER

I@

CLOCK WITH BUZZER- MOUNTING HEIGHT: SEE PLANS

CB
CCTV

BELL, STANDARD 6"- MOUNTING HEIGHT: SEE PLANS PA SYSTEM

CPT

co
CT

cu
@

FLOOR JUNCTION BOX

[J1

DISCONNECT SWITCH - FUSED WHERE APPLICABLE

PI\ SYSTEM SPEAKER - CEILING MOUNTED

I<)

aJ

MOTOR STARTER, COMBINATION WITH DISCONNECT SWITCH

MOTOR STARTER OR CONTROLLER

MOTOR CONNECTION

DC

DIRECT CURRENT

EF
EG
EGU
EM
EMT

EP

EXHAUST FAN
EQUIPMENT GROUNDING
ENGINE GENERATOR UNIT
EMERGENCY
ELECTRICAL METALLIC
CONDUIT
ELECTRICAL NON-METALLIC
CONDUIT
EXPLOSION PROOF

FA
FACP
FC
FU

FIRE ALARM
FIRE ALARM CONTROL PANEL
FAN COIL
FUSE

GND
GFCI

GROUND
GROUND FAULT CIRCUIT
INTERRUPTER
GROUND FAULT INTERRUPTER
GROUND FAULT RELAY

PI\ SYSTEM HORN- MOUNTING HEIGHT: SEE PLANS

EQUIPMENT
MAIN SWITCHBOARD

ENT

CEILING EXHAUST FAN

IG

ISOLATED GROUND

JB

JUNCTION BOX

KAIC

KWH

KILO-AMPS INTERRUPTING
CAPACITY
KILOVOLT
KILOVOLT-AMP
KILOWATT
KILOWATT-HOUR

LPS
LV

LOW PRESSURE SODIUM


LOW VOLTAGE

MCB
MCC
MCP
MFR
MH
MLO
MV

MAIN CIRCUIT BREAKER


MOTOR CONTROL CENTER
MOTOR CIRCUIT PROTECTOR
MANUFACTURER
METAL HALIDE
MAIN LUGS ONLY
MEDIUM VOLTAGE

NIC
NL
NTS

NOT IN CONTRACT
NIGHT LIGHT
NOT TO SCALE

oc

ON CENTER

PA
PT
PVC
PB

PUBLIC ADDRESS
POTENTIAL TRANSFORMER
POLYVINYL CHLORIDE
PULL BOX, ELECTRICAL

KV
KVA

KW

0:i) OR I!!E]

WATER HEATER
POWER POLE: P=POWER, T=TELEPHONE,
D=DATA, C=COMBINATION

OR

--.11111111'
=

BRANCH CIRCUIT PANEL BOARD, SURFACE OR FLUSH


MOUNTED

TEST PORT
LIGHTING CONTROL PANEL
GROUND ROD
)

OR ...-1~-r

GUY WIRE AND ANCHOR

SIGNAL TERMINAL CABINET OR CONTROL PANEL


SURFACE OR FLUSH MOUNTED

GFI
GFR

SIGNAL TERMINAL BACKBOARD

HH
HID
HOA
HP
HPS
HVAC

ACQUISITION &
DEVELOPMENT DIVISION
One Capitol Mall
Sacramento, CA
95814-3229

CALIFORNIA STATE FIRE MARSHAL-APPROVED

Approval of this plan does not authorize or


approve any omission of deviation from
applicable regulations. Final approval is
subject to field inspection. One set of
approved plans shall be available on the
project site
~<(,,
Reviewed b
Date

;;G:

DPR ACCESS COMPLIANCE REVIEW


ACCESSIBILITY SECTION
[\-61..(
CERTIFICATION#

Reviewed

RECPT RECEPTACLE, OUTLET


RIGID GALVANIZED STEEL
RGS
REDUCED VOLTAGE SOFT
RVSS
START
REMOTE TERMINAL UNIT
RTU
TV
TVSS

TELEVISION MONITOR (SET)


TRANS. VOLT. SURGE
SUPPRESSOR

UF
UG
UON
UPS

UNDER FLOOR
UNDERGROUND
UNLESS OTHERWISE NOTED
UNINTERRUPTIBLE POWER
SUPPLY

V
VA
VFD

VOLT
VOLT-AMP
VARIABLE FREQUENCY DRIVE

WP

WEATHERPROOF

XFMR

TRANSFORMER

DISTRIBUTION PANEL BOARD

DENOTES FIXTURE CONNECTED TO EMERGENCY CIRCUIT

ADJUSTABLE SPOT OR FLOOD (ARROW INDICATES AIMING)

BATTERY
BELOW FINISH GRADE

COMBINATION METER/MAIN SERVICE PANEL

<1---

BAT
BFG

AUDIONIDEO OUTLET- MOUNTING HEIGHT: +18" AFF UON

JUNCTION BOX, CODE SIZED UON

<2)

ANN
ATS
AWG

I@I]

SPEAKER- WALL MOUNTED

DEMOLITION
EXISTING
FUTURE
NEW
AMPERES
ALTERNATING CURRENT
AMP FRAME
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR HANDLING UNIT
AMPS INTERRUPTING
CAPACITY
ANNUNCIATOR
AUTOMATIC TRANSFER SWITCH
AMERICAN WIRE GAUGE

CATV OUTLET- MOUNTING HEIGHT: +96" AFF UON

EXIT SIGN, LOW LEVEL


COMBINATION EXIT/EMERGENCY LIGHT FIXTURE
MOUNTING HEIGHT: +8'-0" AFF, UON

A
AC
AF
AFF
AFG
AHU
AIC

I@]

I@

BATH FAN WITH INTEGRAL LIGHT


EXIT SIGN, SINGLE FACE WITH DIRECTIONAL ARROWS AS
INDICATED

TELEPHONE OUTLET FOR WALL MOUNTED TELEPHONE


MOUNTING HEIGHT: +48" AFF UON

FLOOR RECEPTACLE, 15A 125V 2P 3W, GROUNDING TYPE, FLUSH


TYPE UON

o..::lo:....__ _e"-'1 FLUORESCENT FIXTURE, PENDANT OR CABLE HUNG

'SZV

<I

-e
~ OR

INTERCOM CALL IN SWITCH- MOUNTING HEIGHT: +48" AFF, UON

DENOTES # OF
liLEPHONE JACKS

DOUBLE DUPLEX RECEPTACLE, 15A 125V 2P 3W, GROUNDING TYPE,


MOUNTING HEIGHT: +18" AFF UON

WALL-MOUNTED HID, INCANDESCENT, OR COMPACT


FLUORESCENT FIXTURE

([]

DUPLEX RECEPTACLE- CEILING MOUNTED

FLUORESCENT FIXTURE, WALL MOUNTED

CCTV CAMERA, CEILING MOUNT

<I

DUPLEX RECEPTACLE- EMERGENCY POWER

(D)
(E)
(F)
(N)

c:J<1

DUPLEX RECEPTACLE- SPLIT WIRED, SWITCHED

LARGE DIAMETER PENDANT, DEPICTING APPROXIMATE


DIAMETER

COMMUNICATION

by~ DateA;-)&/)1

ACCESSIBILITY COMPLIANCE AND STATE FIRE


MARSHAL SIGNED ORIGINALS ARE ON FILE AT
THE DEPARTMENT OF PARKS AND RECREATION,

NORTHERN SERVICE CENTER

DESIGNED:
DRAWN:

TW
SS

CHECKED:
DATE:

RG
3-21-2011

REVISIONS

Cl

z
w
e>cn

BOLLARD OR POST-TOP FIXTURE


THERMOSTAT (SEE MECHANICAL DRAWINGS)
MOUNTING HEIGHT: +48" AFF UON

KD
SWITCHING

$
$2

BYPASS TIMER OR TIME SWITCH

CONCRETE UNDERGROUND HAND HOLE


(NUMBER DENOTES CHRISTY SIZE)

PUSHBUTTON

TRANSFORMER

LIGHT SWITCH, SPST- MOUNTING HEIGHT: +48" AFF, UON

El
LIGHT SWITCH, DPST- MOUNTING HEIGHT: +48" AFF, UON

HAND HOLE
HIGH INTENSITY DISCHARGE
"HAND-OFF-AUTO" SWITCH
HORSEPOWER
HIGH PRESSURE SODIUM
HEATING, VENTILATION &
AIR-CONDITIONING

~z

-0

cn...JI-

LIGHTING CONTACTOR

$3

LIGHT SWITCH, 3-WAY- MOUNTING HEIGHT: +48" AFF, UON

CONDUIT

,--DENOTES
SV!TCH

$-

LOW VOLTAGE SWITCH, MOMENTARY CONTACT, 3-POS.,


CENTER-OFF, MOUNTING HEIGHT: +48" AFF, UON
MANUAL OVERLOAD TOGGLE SWITCH

1a

DENOTES
SWITCH

LoENOTEs
CIRCUIT

CONDUIT INSTALLED UNDERGROUND OR UNDER SLAB

CIRCUIT AND SWITCH DESIGNATION FOR LIGHTING FIXTURE

----:13
~

CIRCUIT AND RELAY DESIGNATION FOR LIGHTING FIXTURES


(SEE CORRESPONDING LIGHTING CONTROL PANEL RELAY
SCHEDULE)

OCCUPANCY SENSOR, CEILING MOUNTED, LOW VOLTAGE


OCCUPANCY SENSOR, WALL MOUNTED, LINE VOLTAGE,
1-CIRCUIT- MOUNTING HEIGHT: +48" AFF, UON
OCCUPANCY SENSOR, WALL MOUNTED, LINE VOLTAGE,
2-CIRCUIT- MOUNTING HEIGHT: +48" AFF, UON

...,.._
"'
~

~
...,

.9i

PHOTO CONTROL SWITCH - MOUNT ON BUILDING EXTERIOR


TIME CLOCK FOR LIGHTING CONTROL

DEMOLITION NOTE
RACEWAY, FEEDER OR CIRCUIT DESIGNATION (SEE SCHEDULE)

CONDUIT HOME RUN TO DESIGNATED PANEL, TERMINAL, OR


CONTROL CABINET
EXAMPLES: ~
~
L1-6,8
COMMA INDICATES MULTIPLEj
SINGLE POLE CIRCUITS

<(<C

I 101 I

OR

SLASH INDICATESj
MULTI-POLE CIRCUIT

NOTE FOR CONDUIT: THE MINIMUM CONDUIT SIZE IS 3/4". THE


TIC MARKS INDICATE THE QUANTITY OF #12 AWG WIRES OR, IF
INDICATED, THE QUANTITY OF OTHER SIZE WIRE OR CABLES.
SEE THE SINGLE LINE DIAGRAM FOR FEEDER SIZES.
EXAMPLES:
{1,'
= 3/4"C (3) #12
If = 3/4"C (2) #1 0
#10

_,__ = 3/4"C (1) TYPE F1 CABLE.


F1
SEE CABLE SCHEDULE.

-z
~<(

FIXTURE TYPE DESIGNATION


(SEE SCHEDULE)

DENOTES
WATTS
DETAIL
NUMBER

DETAIL INDICATOR

L1-10/12

OCl

DENOTES(f)ENOTES
TYPE
TYPE

180

INDICATES j,
BRANCH PANEL

...J(Q

EI.EC. ROOM ROOM NAME AND NUMBER (SEE ARCHITECTURAL DRAWINGS)

INDICATES CIRCUIT
BREAKER I.D.

LH

al>
~w
>-0::
Cf)(Q

KEYNOTE

t-:'::'-:--7

\
OCCUPANCY SENSOR, CEILING MOUNTED, LINE VOLTAGE

CONDUIT STUB-UP OR STUB-OUT


FLEXIBLE CONDUIT WHIP TO LIGHT FIXTURE OR EQUIPMENT

~
DIMMER SWITCH- MOUNTING HEIGHT: +48" AFF, UON

0
0
ITQJ

EXISTING CONDUIT

DENOTES
CIRCUIT

fDENOTES
RS
6 RELAY

CONDUIT INSTALLED ABOVE GRADE


-----

0~

ANNOTATION

SHEET NUMBER ON WHICH


DETAIL APPEARS

MECHANICAL EQUIPMENT
DESIGNATION
(SEE SCHEDULE)

DATE

(.)

w
....1
w

SECTION
LETTER

SECTION INDICATOR

SHEET NUMBER ON WIHICH


SECTION APPEARS

WINZIER&KELLY

3750 Convoy St. Suite 220


San Diego, CA 92111
tel (858) 244-0440 t fax (858) 244-0441
www.w-and-k.rom

I~===;S;H;EE~T~N;O~.====~
30110.065
I
E-0.1
065