Beruflich Dokumente
Kultur Dokumente
Prepared by :
NDPM
11 October 2012
Huawei Confidential
Methodology
Tools Used :
TEMS Investigation 9.0, Scanner PCTEL Seagull Ex Mini, 2 K800i without external antenna.
Methodology :
Huawei Confidential
Trial Route
Huawei Confidential
Scanner RSCP
Note :
Before Changing parameter
Note :
After Change PCPICH Power from
33dBm to 36dBm
Spot with red circle improved.
Note :
Fallback PCPICH Power from
36dBm to 33dBm
Change MAXTXPOWER from 46 to 43
Huawei Confidential
Scanner EcNo
Note :
Before Change parameter
Note :
After Change PCPICH Power from
33dBm to 36dBm
Spots with red circle improved.
Note :
Fallback PCPICH Power from
36dBm to 33dBm
Change MAXTXPOWER from 46 to 43
UE Idle RSCP
Note :
Before Change parameter
Note :
After Change PCPICH Power from
33dBm to 36dBm
Spot with red circle improved.
Note :
Fallback PCPICH Power from
36dBm to 33dBm
Change MAXTXPOWER from 46 to 43
Huawei Confidential
UE Idle EcNo
Note :
Before Change parameter
Note :
After Change PCPICH Power from
33dBm to 36dBm
Spot with red circle improved.
Note :
Fallback PCPICH Power from
36dBm to 33dBm
Change MAXTXPOWER from 46 to 43
UE Dedicated RSCP
Note :
Before Change parameter
Note :
After Change PCPICH Power from
33dBm to 36dBm
Spot with red circle improved.
Note :
Fallback PCPICH Power from
36dBm to 33dBm
Change MAXTXPOWER from 46 to 43
Huawei Confidential
UE Dedicated EcNo
Note :
Before Change parameter
Note :
After Change PCPICH Power from
33dBm to 36dBm
Spot with red circle improved.
Note :
Fallback PCPICH Power from
36dBm to 33dBm
Change MAXTXPOWER from 46 to 43
Before
Percentage
EcNo
Aftrer 1
Percentage
EcNo
After 2
Percentage
0 t0 -4
0.37%
0 t0 -4
31
2.32%
0 t0 -4
33
2.72%
-4 to -8
405
29.96%
-4 to -8
519
38.76%
-4 to -8
398
32.78%
-8 to -12
467
34.54%
-8 to -12
523
39.06%
-8 to -12
516
42.50%
-12 to -20
475
35.13%
-12 to -20
266
19.87%
-12 to -20
267
21.99%
Total
1352
100.00%
Total
1339
100.00%
Total
1214
100.00%
>= -12
64.87%
>= -12
80.13%
>= -12
78.01%
RSCP
Before
Percentage
RSCP
Aftrer 1
Percentage
RSCP
After 2
Percentage
0 t0 -4
27
1.47%
0 t0 -4
119
7.65%
0 t0 -4
87
5.82%
-4 to -8
553
30.02%
-4 to -8
664
42.70%
-4 to -8
502
33.60%
-8 to -12
608
33.01%
-8 to -12
564
36.27%
-8 to -12
605
40.50%
-12 to -20
654
35.50%
-12 to -20
208
13.38%
-12 to -20
300
20.08%
Total
1842
100.00%
Total
1555
100.00%
Total
1494
100.00%
>= -90
64.50%
>= -90
86.62%
>= -90
79.92%
EcNo
Before
Percentage
EcNo
Aftrer 1
Percentage
EcNo
After 2
Percentage
0 t0 -4
20
1.07%
0 t0 -4
99
6.25%
0 t0 -4
73
4.86%
-4 to -8
554
29.58%
-4 to -8
741
46.81%
-4 to -8
571
38.04%
-8 to -12
714
38.12%
-8 to -12
638
40.30%
-8 to -12
635
42.31%
-12 to -20
585
31.23%
-12 to -20
105
6.63%
-12 to -20
222
14.79%
Total
1873
100.00%
Total
1583
100.00%
Total
1501
100.00%
>= -90
68.77%
>= -90
93.37%
>= -90
85.21%
Huawei Confidential
Note :
EcNo of Scanner
Note :
EcNo of UE Idle
Note :
EcNo of
UE Dedicated
DL Power Blocking
Huawei Confidential
Summary
Purpose of trial :
To make comparison EcNo level when changing parameter
1. PCPICH Power
2. Total DL Power
Conclusion :
1.By increasing PCPICH from 330dBm to 360dBm :
RSCP is maintained
EcNo is slightly improve on some spot
2. Change MAXTXPOWER from 460dBm to 430dBm :
RSCP is slightly decreased at some spot
EcNo is slightly improved on some spots.
3.Best EcNo distribution (samples of >= -12 dB) found in 2nd scenario when CPICH set to 36
dBm while Max Tx Power set to 46 dBm (40W), equal to 10% proportion.
Huawei Confidential
Huawei Confidential
13
11 October 2012