OUTSIDE
SKIN
CONTINUOUS SEALANT
EACH SIDE OF FRAMING TYP.
AS RECOMMENDED
BY MANUFACTURER
FOAM
CORE
DRYWALL
CONTINUOUS SEALANT
AS RECOMMENDED BY MANUFACTURER
CONTINUOUS SEALANT
EACH SIDE OF FRAMING
TYP. AS RECOMMENDED
BY MANUFACTURER
8d COMMON NAILS
@ 6" O.C. EACH SIDE
Fig. 2
DRYWALL
SUBFLOOR OR COMBINED SUBFLOOR
AND UNDERLAYMENT
SIP WALL
DRAINED AND
VENTILATED
CLADDING
FLOOR JOIST
FIELD INSTALLED
PANEL BOTTOM
PLATE
16d NAILS INTO SILL
PLATE @ 16" O.C.
8d COMMON
NAILS @ 6" O.C.
BOTH SIDES
TREATED
SILL PLATE
BE SURE OUTSIDE
SKIN IS SUPPORTED
BY SILL PLATE
SILL SEALER
CONCRETE
OR MASONRY
FOUNDATION
WALL
TERMITE SHIELD
FOUNDATION CONNECTIONS
FOUNDATION CONNECTION DETAIL A
Fig. 3
SIP WALL
DRAINED AND
VENTILATED
CLADDING
DRYWALL
CONTINUOUS SEALANT EACH SIDE OF FRAMING
TYP. AS RECOMMENDED BY MANUFACTURER
8d COMMON
NAILS @ 6"
O.C. EACH SIDE
CAPILLARY BREAK,
MIN. 6 MIL POLY OR
MIN. 3/4" PRESSURETREATED PLYWOOD
UNDER SILL PLATE
AND BOTH FACES
FIELD INSTALLED
TREATED BOTTOM
PLATE
MINIMUM 1/2" (13MM) DIAMETER ANCHOR BOLTS
@ 6 FEET O.C. MAXIMUM
TERMITE SHIELD
CONCRETE OR
MASONRY
FOUNDATION
WALL
FOUNDATION CONNECTIONS
FOUNDATION CONNECTION DETAIL B
Fig. 4
SIP WALL
DRAINED AND
VENTILATED
CLADDING
DRYWALL
FIELD INSTALLED
TREATED BOTTOM
PLATE
8d COMMON
NAILS @ 6"
O.C. EACH SIDE
CONTINUOUS SEALANT
AT EACH SIDE OF
FRAMING TYP. AS
RECOMMENDED BY
MANUFACTURER
USE NAILS PER
MANUFACTURERS
RECOMMENDATIONS
FOR SIZE AND
SPACING
TREATED
SILL PLATE
CAPILLARY BREAK, MIN.
6 MIL POLY OR MIN.
3/4" PRESSURE-TREATED PLYWOOD
UNDER SILL PLATE AND BOTH FACES
CONCRETE
OR MASONRY
FOUNDATION WALL
ANCHOR BOLT AS
REQUIRED BY CODE
FOUNDATION CONNECTIONS
FOUNDATION CONNECTION DETAIL C
Fig. 5
CONTINUOUS SEALANT
EACH SIDE OF FRAMING
AND BOTH FACES
AS RECOMMENDED
BY MANUFACTURER
SEALANT AS
RECOMMENDED BY
MANUFACTURER
SIPS SCREWS WITH 1"
MIN. PENETRATION INTO
STRUCTURAL SUPPORT
@ 24" O.C. MINIMUM
SIP TAPE AT
RIDGE REQUIRED
DRYWALL
CONTINUOUS FIELD
INSTALLED WOOD
RIDGE SUPPORT
BEAM SHOWN
Fig. 6
FINISHED
ROOFING
MATERIAL
BLOCKING AS REQUIRED
BY STRUCTURAL CONDITIONS
ROOFING
FELT
SIP TAPE AT
RIDGE REQUIRED
RIDGE SUPPORT
BEAM
Fig. 7
PANEL SCREW
FINISHED
ROOFING
MATERIAL
ROOFING
FELT
SIP ROOF
PANEL
8d COMMON NAILS
@ 6" O.C. EACH SIDE
CONTINUOUS
SEALANT EACH
SIDE OF FRAMING
AS RECOMMENDED
BY MANUFACTURER,
AND ROOF PANEL
2x JOINT
DRYWALL
TOP PLATE
SIP WALL PANEL
DRAINED AND
VENTILATED
CLADDING
Fig. 8
SIP ROOF
PANEL
CONTINUOUS
SEALANT EACH
SIDE OF FRAMING,
AND ROOF PANEL
2x JOINT
8d COMMON NAILS
@ 6" O.C. BOTH SIDES
TOP PLATE
DRYWALL
CONTINUOUS SEALANT EACH SIDE
OF FRAMING AS RECOMMENDED BY
MANUFACTURER
Fig. 10
8d COMMON NAILS
6" O.C. BOTH SIDES
FINISHED ROOFING
MATERIAL
ROOFING
FELT
SIP TAPE AT
RIDGE REQUIRED
Fig. 11
SECOND FLOOR
DRYWALL
SIP WALL
PANEL
DRAINED AND
VENTILATED
CLADDING
2x BOTTOM
PLATE
8d COMMON
NAILS @ 6"
O.C. BOTH SIDES
FLOOR JOISTS
METAL STRAP
AS REQUIRED
OR LTP4
SIMPSON CLIP
CAP PLATE
CONTINUOUS SEALANT
EACH SIDE OF FRAMING
TYP. AS RECOMMENDED BY
MANUFACTURER
TOP FLANGE METAL FLOOR JOIST
HANGAR (BY OTHERS)
DRYWALL
FIRST FLOOR
Fig. 12
SECOND FLOOR
DRYWALL
SIP WALL
PANEL
DRAINED AND
VENTILATED
CLADDING
2x BOTTOM
PLATE
INSULATION
3/4" T&G FLOOR SHEATHING
(GLUED & NAILED) TO EXTEND
OVER TOP OF SIP WALL
8d COMMON
NAILS @ 6" O.C.
BOTH SIDES
METAL LATERAL
TIE PLATE NAILED
TO BOTTOM OR
SHIM PLATES AND
RIM BOARD
RIM BOARD
METAL LATERAL
TIE PLATE NAILED
TO BOTTOM OR
SHIM PLATES AND
RIM BOARD
FIRST FLOOR
CONTINUOUS SEALANT EACH SIDE OF
FRAMING TYP. AS RECOMMENDED BY
MANUFACTURER
8d COMMON
NAILS @ 6" O.C.
BOTH SIDES
Fig. 13
ROOFING FELT
SIP ROOF PANEL
FINISHED ROOFING MATERIAL
AS REQUIRED, EXTEND ICE
AND WATER SHIELD FROM
FASCIA.
CONTINUOUS
SEALANT EACH SIDE
OF FRAMING TYP. AS
RECOMMENDED BY
MANUFACTURER
CONTINUOUS SEALANT AS
RECOMMENDED BY
MANUFACTURER
ROOF-TO-WALL PANEL
CONNECTION DETAIL
SHOWN ELSEWHERE
DRIP
EDGE
FLASHING
FASCIA
SOFFIT BOARD
EAVES DETAILING
EAVES DETAIL A
Fig. 14
ROOFING FELT
SIP ROOF PANEL
FINISHED ROOFING MATERIAL
AS REQUIRED, EXTEND ICE
AND WATER SHIELD FROM
FASCIA
CONTINUOUS SEALANT
EACH SIDE OF FRAMING
TYP. AS RECOMMENDED
BY MANUFACTURER
DRIP EDGE
FLASHING
CONTINUOUS SEALANT AS
RECOMMENDED BY
MANUFACTURER
ROOF-TO-WALL PANEL CONNECTION
DETAIL SHOWN ELSEWHERE
2X BLOCKING
TO SUPPORT
FASCIA BOARD
8d COMMON NAILS
@ 6" O.C. BOTH SIDES
2x FRAMING MEMBER
FASCIA
SIP SCREW
SOFFIT BOARD
EAVES DETAILING
EAVES DETAIL B
Fig. 15
ROOFING FELT
SIP ROOF PANEL
FINISHED ROOFING MATERIAL
AS REQUIRED, EXTEND ICE
AND WATER SHIELD FROM
FASCIA.
CONTINUOUS SEALANT EACH
SIDE OF FRAMING TYP.
RECOMMENDED BY
DRIP EDGE
ING
AM
R
F
2x
ER
MB
ME
2x FRAMING MEMBER
CONTINUOUS SEALANT
RECOMMENDED BY
MANUFACTURER
8d COMMON NAILS
@ 6" O.C. BOTH SIDES
FASCIA
SOFFIT BOARD
SIP SCREW
EAVES DETAILING
EAVES DETAIL C
Fig. 16
ROOFING FELT
SIP ROOF PANEL
FINISHED ROOFING MATERIAL
AS REQUIRED, EXTEND ICE
AND WATER SHIELD FROM
FASCIA
CONTINUOUS SEALANT EACH
SIDE OF FRAMING TYP. AS
RECOMMENDED BY
MANUFACTURER
DRIP EDGE
FLASHING
8d COMMON NAILS
@ 6" O.C. BOTH
SIDES
CONTINUOUS SEALANT
AS RECOMMENDED BY
MANUFACTURER
BEVELED
BLOCKING
TO SUPPORT
FASCIA BOARD
ROOF-TO-WALL PANEL
CONNECTION DETAIL
SHOWN ELSEWHERE
FASCIA
SOFFIT BOARD
EAVES DETAILING
EAVES DETAIL D
Fig. 17
ROOFING FELT
SIP ROOF PANEL
FINISHED ROOFING MATERIAL
AS REQUIRED, EXTEND ICE
AND WATER SHIELD FROM
FASCIA
CONTINUOUS SEALANT EACH
SIDE OF FRAMING TYP. AS
RECOMMENDED BY
DRIP EDGE
8d COMMON NAILS @
6" O.C. BOTH SIDES
CONTINUOUS SEALANT
AS RECOMMENDED BY
MANUFACTURER
ROOF-TO-WALL PANEL CONNECTION
DETAIL SHOWN ELSEWHERE
USE NAILS PER MANUFACTURER'S
RECOMMENDATIONS FOR SIZE AND
SPACING.
FASCIA
SOFFIT BOARD
EAVES DETAILING
EAVES DETAIL E
Fig. 18
SEALANT AS RECOMMENDED
BY MANUFACTURER
8d COMMON NAILS
@ 6" O.C. EACH STRIP
AND EACH SIDE
Fig. 19
2x FRAMING AROUND
WINDOWS AND DOOR OPENINGS
Fig. 21
8d COMMON NAILS
@ 6" O.C. EACH PANEL
AND EACH SIDE
Fig. 20
CONTINUOUS SEALANT
EACH SIDE OF FRAMING
TYP. AS RECOMMENDED
BY MANUFACTURER
VALLEY
FLASHING
DOUBLE 2x SPLINE
BEVEL CUT
SIPS SCREW
W/ MINIMUM 1"
PENETRATION
INTO STRUCTURAL
SUPPORT
STRUCTURAL SUPPORT
DRYWALL
Fig. 22
SIP TAPE
SIP PANEL
8d COMMON NAILS
@ 6" O.C. EACH PANEL
AND EACH SIDE
CONTINUOUS SEALANT
EACH SIDE OF FRAMING TYP.
AS RECOMMENDED BY
MANUFACTURER
BLOCK SPLINE
Fig. 23