Sie sind auf Seite 1von 16

-

) 1436 (1450


)(Q
)(H
)(pump
)(motor
)(Total

2
1
120
45
75
93
70

95

109
185

92

77

92

185

109

92

( 1 +

386

.
.

294

.
..

92 X

367
)

Q x H x 0.746
75 x Total
1.2 X
77

109

) (

483

..

500

..

) 1450 (1470


)(Q

2
1
155

45
75
93
70

)(H
)(pump
)(motor
)(Total

Q x H x 0.746
75 x Total
1.2 X
99

=
=

120

109
239

119

99

119

239

.
.
.
.

109

348

435

..

)(%80

543

..

630

..

630
500

..
..


-



)(Q
)(H
)(Total
=
=

1
1
10
15
50
Q x H x 0.736

2.94.

1.3

X
4

2.94

3.83

75 x Total

.
.


-
No.


).(

380
380
380
380
380
380

0.5
0.5
3
10
1
4

1
3
3
10
8
4

20
15
5
10
10
5
10
5

20
15
5
10
10
5
10
5

25
18.75
6.25
12.5
12.5
6.25
12.5
6.25

109

136


1
2
3
4
5
6

) (
7
8
9
10
11
12
13
14



)(
) + + (
1-
2-

3
12
1
1
8
2
1
1
1
1
1
1
1
1

2
6
1
1
8
1
1
1
1
1
1
1
1
1

1
6
-1
---

380
380
380
380
380
380
380
380

).( )..(
1.25
3.75
3.75
12.5
10
5


-
1- SHORT CIRCUIT CALCULATIONS AT TRANSFORMER LOW VOLTAGE TERMINAL
Transformer Low Voltage =
Transformer rating =
Transformer impedance (Z) =
Transformer full load current (Ir) =

Short circuit current (Isc) = Ir / Z =

400
630
6.0
957
15

(v)
(KVA)
%
(A)
(KA)

INPUT
CALCULATED

2- GENRATOR CALCULATION TO FEED MAINLOW VOLTAGE PANEL


Generator rating =

Generator full load current (Ir) =

500
760

(KVA)
800
(A)

630
957
1.50
1436

(KVA)
(A)
(A)

0.324
294
95

(KW)
(KVAR)

INPUT
CALCULATED

2- BUSBAR CALCULATION FOR MAINLOW VOLTAGE PANEL


Transformer rating =
Transformer full load current (Ir) =
Bus Bar Seafty Factor =

BUSBAR RATING =

INPUT
2500

CALCULATED

3- POWER FACTOR CORRECTION


Correct Factor From 0.8% TO 0.92 % =
Total Load Power For Low Voltage =
Power Factor For Low Voltage Loads =

INPUT
CALCULATED

THE CAPACITY IS

100

(KVAR)

Transformer
P=
504
S=
630
IF.L
957.6
IC.B = IF.L x1.25
1197
Standerd C.B
1250
K
0.75
Icable = IF.L / K
1277
IC (A) =
435
No.of Cable = Icable/ IC2.9
Selected cable 3(3x240+120) mm/CU/XLPE/SWA/PVC
Generator
P=
400
S=
500
IF.L
760
IC.B = IF.L x1.25
950
Standerd C.B
1000
K
0.75
Icable = IF.L / K
1013
IC (A) =
375
No.of Cable = Icable/ IC2.7
Selected cable 3(3x185+95) mm /CU/XLPE/SWA/PVC
Pump
P=
95
S=
119
IF.L
181
IC.B = IF.L x1.25
226
Standerd C.B
250
K
0.80
Icable = IF.L / K
226
260
IC (A) =
No.of Cable = Icable/ IC
0.87
Selected cable (3x95) + 25E mm /CU/XLPE/PVC


-
KW
KVA
A
A
A
Derating factors
A
(3x240+120) mm- ( in Ground)

ble 3(3x240+120) mm/CU/XLPE/SWA/PVC

KW
KVA
A
A
A
Derating factors
A
(3x185+95) mm- ( in Ground)
nr
ble 3(3x185+95) mm /CU/XLPE/SWA/PVC

KW
KVA
A
A
A
Derating factors
A
(3x95) + 25E mm ( Air)
nr
cable (3x95) + 25E mm /CU/XLPE/PVC


-
LOAD CABACITY
No

TO

FROM

TAG.

CABLE SELECTED CURRENTC.B

Ira (A)

D.Factor

CABLE DATA
laying IZ (A)

(KW)

(V)

504

11000

504
400

400
400

909

0.75

1212

1250

435

3 (3X240+120)

722

0.75

962

1000

375

3 (3X185+95)

95
95
95

400
400
400

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400

4
4

400
400

5
1
1
1
1
1
1
1
1

400
400
400
400
400
400
400
400
400

10
20
15
5

400
400
400
400
400

171
171
171
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
7
7
9
2
2
2
2
2
2
2
2
18
36
27
9
18
18
9
18
9

0.75
0.75
0.75
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.75
0.75
0.75
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75

229
229
229
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
10
10
12
3
3
3
3
3
3
3
3
24
48
36
12
24
24
12
24
12

250
250
250
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
250
250
20
20
20
20
20
20
20
20
20
40
40
40
40
40
40
40
40
40

A
A
A
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
G
G
G
G
G
G
G
G

260
260
260
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
260
260
30
23
23
23
23
23
23
23
23
59
220
185
74
96
74
185
96
74

NO.

STARTER

VD
Path len.
(m)
mv/amp/
m

Insulation

TYPE

CU/XLPE/SWA/PVC, 8.7/15(KV)

FEEDER

CU/XLPE/SWA/PVC

FEEDER
FEEDER

75
90

S.S
S.S
S.S
O/C
O/C
O/C
O/C
O/C
O/C
O/C
O/C
O/C
O/C
O/C
O/C
O/C
O/C
O/C
O/C
DOL
DOL
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER
FEEDER

180
130
50
50
55
190
70
80

Size (mm)

V.D

COMULATIVE V.D

(V)

(V)

0.201
0.201

4.6
4.4

1.1
1.1

4.6
4.4

1.1
1.1

0.52
0.715
3.094
1.982
0.955
1.982
1.982
3.094

3.4
2.5
1.4
1.8
0.9
3.4
2.5
2.2

0.8
0.6
0.3
0.4
0.2
0.8
0.6
0.6

7.9
7.1
6.0
6.4
5.5
8.0
5.2
6.8

2.0
1.8
1.5
1.6
1.4
2.0
1.3
1.6

MEDUEM VOLTAGE SUPPLY


1 R.M.U

TRANSFORMER

3X300

LOW VOLTAGE SUPPLY


1 TRANSFORMER
2 GENERATOR

MDB
MDB

T.R
GE.

CU/XLPE/SWA/PVC

MAIN LOW VOLTAGE PANEL


3
4
5
8
9
10
13
13
14
15
16
17
18
19
20
21
22
23
23
24
25
26
13
14
15
16
17
18
19
20
27
28
29
30
31
32
33
34
35

MDB

PUMP -1
p-1
PUMP -2
p-2
PUMP -3
p-3
electrical Valves for PUMP -1
E.v-p1
electrical Valves for PUMP -2
E.v-p2
electrical Valves for PUMP -3
E.v-p3
electrical Valves - Main
E.v-M
electrical Valves -1
E.v-1
electrical Valves -2
E.v-2
electrical Valves -3
E.v-3
electrical Valves -4
E.v-4
electrical Valves -5
E.v-5
electrical Valves -6
E.v-6
electrical Valves -7
E.v-7
electrical Valves -8
E.v-8
electrical Valves -9
E.v-9
electrical Valves -10
E.v-10
electrical Valves -11
E.v-11
electrical Valves 12
E.v-12
Dewetring Pump-1
DP-1
Dewetring Pump-2
DP-2
CRANE
CR
VENTILATOR-1
V-1
VENTILATOR-2
V-2
VENTILATOR-3
V-3
VENTILATOR-4
V-4
VENTILATOR-5
V-5
VENTILATOR-6
V-6
VENTILATOR-7
V-7
VENTILATOR-8
V-8
PUMP STATION LIGHT PANEL
LP-P
ADMINSTRATION BUILDING
LP-AD
CHLORINATION BUILDING
LP-CHL
ELECTRICAL BUILDING
LP-EL
GENERATOR BUILDING
LP-GE
GURD-1 & EXTERNAL LIGHITING PANE LP-G-1
GURD-2 LIGHITING PANEL
LP-G-2
WORKSHOP BUILDING
LP-WS
STORE BUILDING
LP-ST

10
10
5
10
5

400
400

400
400

(3X95)
(3X95)
(3X95)

CU/XLPE/PVC
CU/XLPE/PVC
CU/XLPE/PVC

(4x2.5)
(4x2.5)
(4x2.5)
(4x2.5)
(4x2.5)
(4x2.5)
(4x2.5)
(4x2.5)
(4x2.5)
(4x2.5)
(4x2.5)
(4x2.5)
(4x2.5)
(4x2.5)
(4x2.5)
(4x2.5)

CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC

(4X4)
(4X4)

CU/XLPE/PVC
CU/XLPE/PVC

(4X4)
(3x3)
(3x3)
(3x3)
(3x3)
(3x3)
(3x3)
(3x3)
(3x3)
(4X10)
(3X70+35)
(3X50+25)
(4X10)
(4X16)
(4X35)
(4X16)
(4X16)
(4X10)

CU/XLPE/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC
CU/PVC/PVC

CU/XLPE/PVC
CU/XLPE/SWA/PVC
CU/XLPE/SWA/PVC
CU/XLPE/SWA/PVC
CU/XLPE/SWA/PVC
CU/XLPE/SWA/PVC
CU/XLPE/SWA/PVC
CU/XLPE/SWA/PVC
CU/XLPE/SWA/PVC

Remarks