Sie sind auf Seite 1von 6

PFD Modification

Candidate for Heat Integration


Column 2
40C
140C

180C

20C

Process Integration Background

250C

230C

Column 3

Reactor

Column 1

200C

Process Integration - Background

80C

Feasible Heat Exchange


Tpinch
Ts = 250C
Ts = 200C

Tt = 40

Tt = 80

Tt = 180C
Tt = 230C

Qc= 10.0 MW

QH = 7.5 MW

Process Integration - Background

Ts = 20

Design after
Heat Integration
140C
250C

180C

Reactor

230C
7.5 MW

80C

4
5

10 MW
20C

40C

200C

Candidate for Heat Integration


FCp=2 MW/C
40C
180C

180C
60C

Column 2

Reactor

FCp=3 MW/C
105C
Column 3
30C

150C

FCp=2.6 MW/C

40C

FCp=4 MW/C
Process Integration Background

Process Integration - Background

1. For Tmin= 10 oC, find pinch temperature and determine


minimum cooling and heating utility.
2. What is the maximum heat recovery potential for this
problem?
3. Calculate percentage savings on cooling and heating
utility.
4. Design heat exchanger network (HEN) to achieve (1)
5. Redraw the process flowsheet to represent HEN in (4)

Process Integration Background