Deflection Check for a Slab

(Based on CP-65)

SLAB NAME
Type -3
Thickness of the slab
=
180
Effective Depth of the slab considered
=
155
Length of the slab
=
2500
Width of the slab considered
=
1000
Strength of the concrete used,fcu
=
40
Strength of the steel Reinf., fy
=
460
Parameters for Modification Factor Calculations
Area of Reinforcement Required, Asreq
=
1230
Area of Tension Reinf Prov, Asprov
=
2011
Area of Compression Reinf. Prov Asprov
=
664
Stress in Steel,fs
=
175.85
Ultimate Moment
=
55
Span/Effective Depth Ratio based on C
=
7
Tension Modification Factor,Mod(ten)
Compression Modification factor,Mod(c

=
=

1.3369
1.125

Allowable Span/ Depth Ratio


Assumed Span Depth Ratio

=
=

10.528
16.129