Beruflich Dokumente
Kultur Dokumente
Date
Revision
08/12/2010
R0
Prepared by
SC
Contract No.
Checked by
SC
Client
Project
Approved by
PS
Doc. No.
EQUIPMENT DESIGNATION
FROM
INTERCONNECTION DETAILS
LENGTH
PANEL
NO./MODULE
NO.
TO
SIZE
ROUTE
MTRS.
9-GF-1-01
CHP LCSS#1
7R6
3Cx2.5 sq mm Cu
As per site
210
9-GF-1-02
CHP LCSS#1
15F3
3Cx2.5 sq mm Cu
As per site
210
9-GF-1-03
CHP LCSS#1
3R2
3Cx2.5 sq mm Cu
As per site
210
9-GF-1-04
CHP LCSS#1
13F1
3Cx2.5 sq mm Cu
As per site
210
9-GF-1-05
CHP LCSS#1
3R3
3Cx2.5 sq mm Cu
As per site
210
9-GF-1-06
CHP LCSS#1
13R5
3Cx2.5 sq mm Cu
As per site
210
9-GF-1-07
CHP LCSS#1
5R4
Vibrating Feeder - VF # 1A
3Cx2.5 sq mm Cu
As per site
75
9-GF-1-08
CHP LCSS#1
14R2
Vibrating Feeder - VF # 1B
3Cx2.5 sq mm Cu
As per site
80
9-GF-1-09
CHP LCSS#1
5R3
Vibrating Feeder - VF # 2A
3Cx2.5 sq mm Cu
As per site
75
9-GF-1-10
CHP LCSS#1
13R4
Vibrating Feeder - VF # 2B
3Cx2.5 sq mm Cu
As per site
80
9-GF-1-11
CHP LCSS#1
4F1
Vibrating Feeder - VF # 3A
3Cx2.5 sq mm Cu
As per site
75
9-GF-1-12
CHP LCSS#1
16F4
Vibrating Feeder - VF # 3B
3Cx2.5 sq mm Cu
As per site
80
9-GF-1-13
CHP LCSS#1
6F4
Sump Pump-1A
3Cx2.5 sq mm Cu
As per site
130
9-GF-1-14
CHP LCSS#1
15R2
Sump Pump-1B
3Cx2.5 sq mm Cu
As per site
130
9-GF-1-15
CHP LCSS#1
6F1
Belt Conveyor-BC-1A
3Cx16 sq mm Al
As per site
75
9-GF-1-16
CHP LCSS#1
18F1
Belt Conveyor-BC-1B
3Cx16 sq mm Al
As per site
75
9-GF-1-17
CHP LCSS#1
6R2
OBMS-1A
3Cx4 sq mm Cu
As per site
150
9-GF-1-18
CHP LCSS#1
13F3
OBMS-1B
3Cx4 sq mm Cu
As per site
150
9-GF-1-19
CHP LCSS#1
1F1
Belt Conveyor-BC-2A
3Cx300 sq mm Al
As per site
75
9-GF-1-20
CHP LCSS#1
1F1
Belt Conveyor-BC-2A
2CX2.5(CU)
As per site
75
CORE
FROM
CHP LCSS#1
20F1
Belt Conveyor-BC-2B
3Cx300 sq mm Al
As per site
Page 1 of 5
55
31
32
R
APPLICATION
TO
9-GF-1-20
CHP LCSS #1 LV
SWGR.-LV Power
3VYN492201-5
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
Motor space
heater
U
Sheet No.
/ Remarks
Power Cables
ABB Limited
Date
Revision
08/12/2010
R0
Prepared by
SC
Contract No.
Checked by
SC
Client
Project
Approved by
PS
Doc. No.
EQUIPMENT DESIGNATION
FROM
9-GF-1-21
CHP LCSS#1
LENGTH
PANEL
NO./MODULE
NO.
TO
SIZE
ROUTE
MTRS.
20F1
Belt Conveyor-BC-2B
2CX2.5(CU)
As per site
55
9-GF-1-22
CHP LCSS#1
6R5
Metal Detector-1A
3Cx2.5 sq mm Cu
As per site
60
9-GF-1-23
CHP LCSS#1
16R2
Metal Detector-1B
3Cx2.5 sq mm Cu
As per site
60
9-GF-1-24
CHP LCSS#1
6F2
Flap Gate-1A
3Cx2.5 sq mm Cu
As per site
60
9-GF-1-25
CHP LCSS#1
17R3
Flap Gate-1B
3Cx2.5 sq mm Cu
As per site
60
9-GF-1-25
CHP LCSS#1
6F3
3Cx2.5 sq mm Cu
As per site
70
9-GF-1-26
CHP LCSS#1
18R4
3Cx2.5 sq mm Cu
As per site
70
9-GF-1-27
CHP LCSS#1
5F3
3Cx2.5 sq mm Cu
As per site
70
9-GF-1-28
CHP LCSS#1
15F4
3Cx2.5 sq mm Cu
As per site
70
9-GF-1-29
CHP LCSS#1
4F2
Vibrating Feeder - VF # 4A
3Cx2.5 sq mm Cu
As per site
70
9-GF-1-30
CHP LCSS#1
8F4
Vibrating Feeder - VF # 4B
3Cx2.5 sq mm Cu
As per site
75
9-GF-1-31
CHP LCSS#1
3F3
Vibrating Feeder - VF # 5A
3Cx2.5 sq mm Cu
As per site
75
9-GF-1-32
CHP LCSS#1
14R3
Vibrating Feeder - VF # 5B
3Cx2.5 sq mm Cu
As per site
75
9-GF-1-33
CHP LCSS#1
8F2
Vibrating Screen-1A
3Cx25 sq mm Al
As per site
110
9-GF-1-34
CHP LCSS#1
13R1
Vibrating Screen-1B
3Cx25 sq mm Al
As per site
110
9-GF-1-35
CHP LCSS#1
6R1
Vibrating Screen-2A
3Cx25 sq mm Al
As per site
75
9-GF-1-36
CHP LCSS#1
13R4
Vibrating Screen-2B
3Cx25 sq mm Al
As per site
75
9-GF-1-37
CHP LCSS#1
4R2
Flap Gate-5
3Cx2.5 sq mm Cu
As per site
75
9-GF-1-38
CHP LCSS#1
8R1
Belt Conveyor-BC-3A
3Cx120 sq mm Al
As per site
100
9-GF-1-39
CHP LCSS#1
8R1
Belt Conveyor-BC-3A
2CX2.5(CU)
As per site
100
9-GF-1-40
CHP LCSS#1
16R1
Belt Conveyor-BC-3B
3Cx120 sq mm Al
As per site
100
9-GF-1-41
CHP LCSS#1
16R1
Belt Conveyor-BC-3B
2CX2.5(CU)
As per site
100
INTERCONNECTION DETAILS
CORE
FROM
31
32
Page 2 of 5
57
58
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-08-20
1450-04-07,Rev-C
1450-08-20
57
58
Motor space
heater
Motor space
heater
Sheet No.
DRG. NO.
Motor space
heater
APPLICATION
TO
CHP LCSS #1 LV
SWGR.-LV Power
3VYN492201-5
/ Remarks
Power Cables
ABB Limited
Date
Revision
08/12/2010
R0
Prepared by
SC
Contract No.
Checked by
SC
Client
Project
Approved by
PS
Doc. No.
EQUIPMENT DESIGNATION
FROM
PANEL
NO./MODULE
NO.
LENGTH
TO
SIZE
ROUTE
MTRS.
9-GF-1-42
CHP LCSS#1
4R3
Flap Gate-2
3Cx2.5 sq mm Cu
As per site
80
9-GF-1-43
CHP LCSS#1
15R6
Flap Gate-7
3Cx2.5 sq mm Cu
As per site
80
9-GF-1-44
CHP LCSS#1
8R3
Flap gate-6A
3Cx2.5 sq mm Cu
As per site
80
9-GF-1-45
CHP LCSS#1
14R5
Flap gate-6B
3Cx2.5 sq mm Cu
As per site
100
9-GF-1-46
CHP LCSS#1
5R2
Belt Conveyor-10
3Cx4 sq mm Cu
As per site
80
9-GF-1-47
CHP LCSS#1
14F1
3Cx16 sq mm Al
As per site
100
9-GF-1-48
CHP LCSS#1
9R1
Belt Conveyor-7
3Cx120sq mm Al
As per site
90
9-GF-1-49
CHP LCSS#1
9R1
Belt Conveyor-7
2CX2.5(CU)
As per site
90
INTERCONNECTION DETAILS
CORE
FROM
R
Y
Y
9-GF-1-51
CHP LCSS#1
CHP LCSS#1
16F1
9F1
Belt Conveyor-8
Belt Conveyor-9
3Cx16 sq mm Al
3Cx25 sq mm Al
As per site
As per site
110
110
9-GF-1-52
CHP LCSS#1
10F1
Yard Conveyor-1A
3Cx300 sq mm Al
As per site
125
9-GF-1-53
CHP LCSS#1
10F1
Yard Conveyor-1A
2CX2.5(CU)
As per site
125
9-GF-1-54
CHP LCSS#1
12F1
Yard Conveyor-1B
3Cx300 sq mm Al
As per site
125
9-GF-1-55
CHP LCSS#1
12F1
Yard Conveyor-1B
2CX2.5(CU)
As per site
125
31
32
R
7R2
OBMS-2A
3Cx4 sq mm Cu
As per site
110
9-GF-1-57
CHP LCSS#1
18R2
OBMS-2B
3Cx4 sq mm Cu
As per site
110
9-GF-1-58
CHP LCSS#1
3R5
3Cx16 sq mm Al
As per site
55
9-GF-1-59
CHP LCSS#1
16F2
3Cx16 sq mm Al
As per site
55
9-GF-1-60
CHP LCSS#1
7F2
3Cx16 sq mm Al
As per site
75
9-GF-1-61
CHP LCSS#1
14F2
3Cx16 sq mm Al
As per site
75
Page 3 of 5
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-08-20
31
2
CHP LCSS#1
motor space
heater
B
9-GF-1-56
58
R
Motor space
heater
32
R
Motor space
heater
Sheet No.
57
APPLICATION
TO
B
9-GF-1-50
CHP LCSS #1 LV
SWGR.-LV Power
3VYN492201-5
/ Remarks
1450-08-17
1450-08-18
1450-08
1450-08-20
1450-08
1450-08-20
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
Power Cables
ABB Limited
Date
Revision
08/12/2010
R0
Prepared by
SC
Contract No.
Checked by
SC
Client
Project
Approved by
PS
Doc. No.
EQUIPMENT DESIGNATION
FROM
PANEL
NO./MODULE
NO.
LENGTH
TO
SIZE
ROUTE
MTRS.
9-GF-1-62
CHP LCSS#1
8F3
3Cx16 sq mm Al
As per site
70
9-GF-1-63
CHP LCSS#1
15R4
3Cx16 sq mm Al
As per site
100
9-GF-1-64
CHP LCSS#1
9F2
3Cx16 sq mm Al
As per site
100
9-GF-1-65
CHP LCSS#1
13F2
3Cx16 sq mm Al
As per site
80
9-GF-1-66
CHP LCSS#1
6R3
3Cx16 sq mm Al
As per site
100
9-GF-1-67
CHP LCSS#1
20F2
3Cx300 sq mm Al
As per site
100
9-GF-1-68
CHP LCSS#1
20F2
2CX2.5(CU)
As per site
100
9-GF-1-69
CHP LCSS#1
7F3
3Cx2.5 sq mm Cu
As per site
100
9-GF-1-70
CHP LCSS#1
17F2
3Cx2.5 sq mm Cu
As per site
100
9-GF-1-71
CHP LCSS#1
5F4
Screw Conveyor-1A
3Cx2.5 sq mm Cu
As per site
100
9-GF-1-72
CHP LCSS#1
13F5
Screw Conveyor-1B
3Cx2.5 sq mm Cu
As per site
100
9-GF-1-73
CHP LCSS#1
3R1
3Cx25 sq mm Al
As per site
100
9-GF-1-74
CHP LCSS#1
17R2
3Cx25 sq mm Al
As per site
100
9-GF-1-75
CHP LCSS#1
18F4
3Cx 16 sq mm Al
As per site
50
9-GF-1-76
CHP LCSS#1
7R5
3Cx 16 sq mm Al
As per site
100
9-GF-1-77
CHP LCSS#1
5R1
3Cx25 sq mm Al
As per site
100
9-GF-1-78
CHP LCSS#1
15R1
3Cx25 sq mm Al
As per site
100
9-GF-1-79
CHP LCSS#1
7R4
3Cx 16 sq mm Al
As per site
100
9-GF-1-80
CHP LCSS#1
15R5
3Cx 16 sq mm Al
As per site
100
9-GF-1-81
CHP LCSS#1
5F1
3Cx185 sq mm Al
As per site
100
9-GF-1-82
CHP LCSS#1
13R2
3Cx4 sq mm Al
As per site
100
9-GF-1-83
CHP LCSS#1
5F2
Lighting Load
3Cx95 sq mm Al
As per site
30
Page 4 of 5
CHP LCSS #1 LV
SWGR.-LV Power
3VYN492201-5
INTERCONNECTION DETAILS
CORE
FROM
R
Y
APPLICATION
TO
B
31
32
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-08-20
Motor space
heater
Sheet No.
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
/ Remarks
Power Cables
ABB Limited
Date
Revision
08/12/2010
R0
Prepared by
SC
Contract No.
Checked by
SC
Client
Project
Approved by
PS
Doc. No.
EQUIPMENT DESIGNATION
FROM
PANEL
NO./MODULE
NO.
LENGTH
TO
SIZE
ROUTE
MTRS.
9-GF-1-84
CHP LCSS#1
8F1
3Cx300 sq mm Al
As per site
30
9-GF-1-85
CHP LCSS#1
7R3
DC Battery Charger
3Cx25 sq mm Al
As per site
30
9-GF-1-86
CHP LCSS#1
4R4
UPS
3Cx16 sq mm Al
As per site
30
9-GF-1-87
CHP LCSS#1
3R4
Dewatering pumps
3Cx2.5 sq mm Cu
As per site
50
CHP LCSS #1 LV
SWGR.-LV Power
3VYN492201-5
INTERCONNECTION DETAILS
CORE
FROM
R
Y
APPLICATION
TO
R
Sheet No.
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
1450-04-07,Rev-C
/ Remarks
Note :- The route length indicated are tentative. Site Engineer to ensure actual route length before cutting the Cable From Drum.
Page 5 of 5
Power Cables