MEASUREMENT OF REACTIVE POWER OF STAR AND

DELTA CONNECTED BALANCED LOADS


AIM: To measure active power of star and delta loads by single wattmeter method.
APPARATUS:
SL.NO
1
2
3
4
5
6
7

EQUIPMENT
Rheostats
Capacitors
Ammeter
voltmeter
wattmeter
3- variac
Connecting wires

RATING
300/1.7A
25F
(0-1A)
(0-600V)
(600V,2.5A)
415/(440-470)V
------------

TYPE
WW
Parallel plate
MI
MI
UPF
---------------------

QUANTITY
3
3
1
1
1
1
As per required

CIRCUIT DIAGRAM:

(0-20)A MC
R

50
(0-600V)

50

MI
50

600V,2A,UPF

(0-20)A MC

200
(0-600V)

200

MI
200
Y

600V,2A,UPF

PROCEDURE:
1. Connect the circuit as per the circuit diagram.
2. Make sure that the knob of three phase variac is in minimum voltage position.
3. Now feed variac and apply different voltages to three phase load.
4. Now note down readings of voltmeter, ammeter and wattmeter without parallax error.
5. Disconnect the circuit after the experiment is over.

OBSERVATION TABLE:

STAR CONNECTED:SL. NO

VL(V)

IL(A)

W(WATTS)

SIN

COS

REACTIV
E POWER
( 3W

IL(A)

W(WATTS)

SIN

COS

REACTIV
E POWER
( 3W

1
2
3
4
5
6
DELTA CONNECTED:SL. NO

VL(V)

1
2
3
4
5
6
PRECAUTIONS:
1. Avoid making loose connections.
2. Readings should be taken carefully without parallax error.
3. Handle instruments with care and operate smoothly.
RESULT: Measurement of three phase power with single wattmeter is hence verified.