Beruflich Dokumente
Kultur Dokumente
Temperature
(C)
Pressure
(bar)
Initial volume,V1
(L)
Final volume, V0
(L)
V0- V1
(L)
25.0
26.259
11.480
11.503
0.023
25.0
26.143
11.952
11.976
0.024
25.1
25.040
11.503
11.528
0.025
25.1
26.001
10.758
10.783
0.025
25.7
26.037
11.118
10.143
0.025
Ref.
24.9
27.751
34.872
34.900
0.028
Four minutes
1
25.0
22.789
11.503
11.531
0.028
25.0
19.262
11.976
12.002
0.026
25.1
14.694
11.528
11.551
0.023
25.0
9.886
10.783
10.818
0.035
25.5
5.547
10.143
10.170
0.033
Ref
24.9
25.535
34.900
34.929
0.029
RESULTS
Meter
Temperature
(C)
Pressure
(bar)
Initial
volume,V1
(L)
First two minutes
25.8
23.484
Ref.
25.9
25.895
Final volume,
V0
(L)
V0- V1
(L)
11.531
11.560
0.029
34.929
34.951
0.022
Four minutes
1
25.0
23.499
11.560
11.580
0.020
Ref
24.9
25.908
34.951
34.970
0.019
Meter
Temperature
(C)
Pressure
(bar)
Final volume,
V0
(L)
V0- V1
(L)
25.2
24.903
12.002
12.025
0.013
Ref
24.9
26.696
34.970
34.982
0.012
Initial
volume,V1
(L)
First two minutes
Four minutes
2
25.2
25.209
12.025
12.034
0.009
Ref
24.9
26.894
34.982
34.992
0.010
Meter
Temperature
(C)
Pressure
(bar)
Initial
volume,V1
(L)
First two minutes
25.3
23.534
Ref
25.0
25.872
Final volume,
V0
(L)
V0- V1
(L)
11.551
11.565
0.019
34.992
35.011
0.019
Four minutes
3
25.3
23.569
11.565
11.590
0.025
Ref
25.0
25.889
35.011
35.030
0.019
Meter
Temperature
(C)
Pressure
(bar)
Final volume,
V0
(L)
V0- V1
(L)
25.3
23.486
10.818
10.839
0.021
Ref
25.0
23.883
35.030
35.050
0.020
Initial
volume,V1
(L)
First two minutes
Four minutes
4
25.2
23.446
10.839
10.858
0.019
Ref
25.0
25.887
35.050
35.069
0.019
Meter
Temperature
(C)
Pressure
(bar)
Initial
volume,V1
(L)
First two minutes
25.8
23.562
Ref
25.0
25.875
Final volume,
V0
(L)
V0- V1
(L)
10.170
10.189
0.019
35.069
35.088
0.019
Four minutes
5
25.7
23.587
10.189
10.208
0.019
Ref
25.0
25.912
35.088
35.102
0.014
Meter y
Simultaneous
seperately
% errors
% correction
% errors
% correction
3.57
3.45
5.00
5.26
11.54
10.34
11.11
10.00
26.10
20.69
24.00
31.58
17.14
20.69
0.00
0.00
12.12
13.79
26.32
35.71
SAMPLE CALCULATIONS
V = V0 V1
=11.503 11.480
= 0.023 L
% Error
= (Meter Y reading Ref meter reading) / Meter Y reading 100%
= | (0.028 0.029)/ 0.028 | 100%
= 3.57 %
% Correction
= (Meter Ref reading Meter Y reading) / Meter Ref reading 100%
= | (0.029 0.028)/ 0.029 | 100%
= 3.45 %