Zones in Room 2
150 150
mmmm
150 mm
Entrance
to room 1
Light
switch
this side
100 mm
or less
13A socket-outlet
reverse side
The doorway between Rooms 1 and 2 allows the location of an accessory on one side of the wall to be determined from the reverse side.
If the wall or partition is 100 mm or less, the zones created due to the accessory extend to the reverse side.
Cables concealed in a wall of a room containing a bath or shower need to meet the requirements of Regulation 601-07.
The contractor should make the client aware of the permitted cable route zones.
150
150 mm
mm
150 mm
Light
switch
reverse
side
Entrance
to room 2
13A socket-outlet
this side
Cooker
control
switch