Supply Voltage 100-120/220-240/380-440 V AC ±20% 100-120/220-240/380-440 V AC ±20% 110/ 220/ 380/ 415 VAC ± 10%, 380 – 440 VAC, ± 20%, 3PH-3 Wire
System 50 / 60 Hz 50 / 60 Hz 50/ 60 Hz
Note: Mention specific voltage
( Fixed/wide range ) in order Auxiliary 100-120/220-240/380-440 V AC ±20% 100-120/220-240/380-440V AC ±20% Bulit-In Built-In from 3-Phase
Output Contacts 1 CO 2 CO 2 CO 1 CO
Trip Setting (Volts)
Phase Sequence Yes Yes Yes Yes
Phase Unbalance 40 V ±6 V (fixed) 30 V to 70 V ±6 V (adjustable) 30 V to 70 V ± 6 V (adjustable) -
14
Unbalance
Td : 2-5 Sec. 3 9 >30 - 70 V Set Value
Td : 2-5 Sec. 1 11
16
13
13 14 11 10
1 4 11 8
18
15
13 15 11 12
16
13
R
L1
R
L1
R
L2 L2
Y Y
L3 L3
B
OFF
B
OFF
Y
ON ON
N/V N/V B
DOL STARTER DOL STARTER
1 2 3 4 5 6
1 2 3 VSP D2 P2 PFS1
VSP D1
AUX.
AUX. SUPPLY
SUPPLY
7 8 9 10 11 12
7 8 9
5 6 7
4 8
13 14 15 13 14 15 16 17 18
3 9
2 10
1 11
Bottom view
10
P H A S E F A I L U R E R E L A Y S
P1 PFS1 VPG D1 P1 PFS2 S2 VMR1
Phase Failure Relay +
Phase Failure Relay Low water level guard Phase Failure Relay Phase Failure Relay
C US
Phase Sequence, Single phasing, reverse phasing, Phase Failure, Unbalance, Microcontroller design,
Auto Reset, unbalanced supply, Auto reset, Phase Sequence, SMD Technology,
1 CO output relay 1 CO output contact Auto Reset, Phase Failure, Unbalance,
Suitable for any HP/kW rating fixed unbalance setting, Phase Sequence
submersible pumps 1 CO output relay Auto/Manual Reset,
Low water level guard for dry Adjustable Unbalance setting,
running protection 2 CO output relay
110/ 220/ 380/ 415 VAC ± 10%, 50 / 60 Hz 415VAC ± 20%, 50 Hz ± 3% 110 / 240 / 380 / 415 V AC ±10%, 50 / 60 Hz 100-120 / 220-240 / 380-440V AC, -25+20%, 48-63 Hz
Instant 3.5 Sec ± 1.5 Sec 3.5 sec. ±1.5 sec. 4 Sec ± 1 Sec / RP-Instant
N.A. 3.5 Sec ± 1.5 Sec N.A. N.A.
Auto Reset Auto Reset Auto Auto/ Manual Reset (Selectable by Front Push Button)
90 gms. 300 gms. 175 gms. 100 gms (Approx.)
RYB R B Y R B R Y B
RYB R B Y R Y B RYB R B Y R B R Y B
3 Ph
Td : 3-5 Sec.
Td : 2-5 Sec.
7 8 1 3 Unbalance
8 11 >4 - 20 %
7 10
1 8 1 4 7 9 10 12
L1 R
R R
R Y
L2
Y B
Y L3 Y
B
B
B
N/V
P1 PFS1
OFF
4 5 ON
3 6 NO 4 5
1 2 3
8 7 3 6
2 7 VPG D1
1 8 2 7
NC PROD
Bottom view 1 8 7 8 9 1 8
13 14 15
WATER TANK
Bottom view
C US
Supply Voltage
415 VAC ± 20%, 50 Hz ± 3% 100-110-120 / 220-230-240 / 380-415-440V AC -25+20%,
Note: Mention specific voltageSystem Selectable by Front Knob, 48-63 HZ 110 / 240 / 380 / 415 / 440 V AC ±20%, 50 / 60 Hz
( Fixed/wide range ) in order
Auxiliary Built In Built In (from 3 Phase) 110 V (Fixed) or (220-230-240) or (380-415-440) VAC
Output Contacts 1 CO 2 CO 2 CO
Trip Setting (Volts)
Phase Sequence Yes Yes Yes
Phase Unbalance 60 V± 6 V (fixed) 10% (Fixed) ± 10% 40 V ±6 V (fixed)
Under For 380-440V AC 80% to 95% (adjustable)
Voltage For 220-240V AC
For 100-120V AC
N.A ± 20% (Fixed)
Over For 380-440V AC 105% to 120% (adjustable)
Voltage For 220-240V AC
For 100-120V AC
Trip Time Delay
On Phase Failure 3.5 sec. ± 1.5 sec. 2 - 5 Sec. (Fixed) / RP-Instant 3.5 secs. ± 1.5 sec
On UV/OV Less than 2 secs. for OV & 2 - 5 secs for UV
Resetting Mode Auto Reset Auto Reset Manual / Remote
Weight 100 gms (Approx.) 100 gms (Approx.) 430 gms.
Dimensions (mm)
Overall (L x W x D) 76 x 30.5 x 117.5 90 X 35 X 60 76 x 56.5 x 117.5
Mounting (L x W) 68 centre to centre / 35 mm rail Mounting 35 mm Rail Mounting 67 x 46 / 35 mm rail Mounting
• * CE marked products 1 2 7 8 10 11
Phase Fail
Td : 2-5 Sec.
available on request. 13 14 16 17
1 3 7 9 10 12 13 15 16 18
R
R
M
L L
Y O
A Y O
A R
L1
L
D D
B B Y
L2 O
MOTOR
A
L3 D
B
OFF ON
N/V
DOL STARTER
USP D1
1 2 3 4 5 6
HLV D2
AUX.
SUPPLY
7 8 9 10 11 12
13 14 1516 17 18
Phase Failure, Unbalance, Phase Failure, Unbalance, Phase Failure, Unbalance, Phase
Phase Sequence, under voltage, Phase Sequence, under voltage, Sequence,
Over Voltage, Auto Reset, Over Voltage, Auto Reset, Under Voltage, Over Voltage, Auto
Fixed Unbalance setting, Fixed Unbalance setting, Reset, Fixed Unbalance Settings,
Adjustable UV/OV settings, Adjustable UV/OV settings, Adjustable UV/ OV Settings, Neutral
2 CO output relay 2 CO output relay Fail, 2 CO output relay
415 V AC ± 20%
110 / 240 / 380 / 415 / 440 V AC ±20%, 50 / 60 Hz 110/220/230/240/380/415/440 V AC ±20%, 50/60 Hz
110 V (Fixed) or (220-230-240) or (380-415-440) VAC ±20% selectable 110/220/230/240/380/415/440 V AC ±20%, 50/60 Hz Built-In
2 CO 2 CO 2 CO
105% to 120% (adjustable) 105% to 120% (adjustable) 105% to 125% of 415 VAC
3.5 secs. ± 1.5 sec 3.5 secs. ± 1.5 sec 5 sec. ± 1 sec for UB/SP/UV/OV, Instant for RP,
Less than 2 secs. Less than 2 secs. Less than 2 secs. for NF.
Auto Reset Auto Reset Auto Reset
400 gms. 400 gms. 110 gms.
OV
OV OV RYBN RY RBYN RYBN
UV UV Unbalance /
Aux Aux UV
Supply Supply
3 Ph-N Phase fail
13 15 16 18 13 15 16 18
7 9 10 12
R
L1 L1 L
R R
L L Y O
L2 O L2 A
R Y
L3
MOTOR
A
D
Y
L3
MOTOR
O
A B D
D
B B N
OFF ON OFF ON
N/V N/V OFF
N/V
DOL STARTER DOL STARTER ON
DOL STARTER
S2 VMR6
1 2 3 4 5 6 1 2 3 4 5 6
ALV D2
VMR D2
AUX. AUX.
SUPPLY SUPPLY
7 8 9 10 11 12 7 8 9 10 11 12
13 14 1516 17 18 13 14 1516 17 18
Phase Failure, Unbalance, Phase Failure, Unbalance, Phase Failure, Phase Sequence,
Phase Sequence, Phase Sequence, under voltage, Auto Reset,
Under Voltage, Over Voltage, under voltage, Over Voltage, Adjustable trip delay,
Auto Reset, Fixed Unbalance Auto reset, Fixed Unbalance Adjustable UV setting,
Settings, Fixed UV/ OV setting, Fixed UV/OV settings, 1 CO output relay
Settings, 2 CO output relay 2 CO output relay Selectable range of supply
voltage
Over For 380-440V AC 110 % of 415 V AC (fixed) 120% of system supply (Fixed) N.A.
Voltage For 220-240V AC
For 100-120V AC
3 2 6 5 13 15 1 3 13 15
L1
R R L
L L
O L2 O
Y O Y
A A A
B D L3 D
D B
OFF
OFF ON
N/V
N/V
18 16 15 28 26 25
ON
DOL STARTER
1 2 3
S2 VMR8
VST D1
L3 L2 L1
D1 HLS1
7 8 9
13 14 15
R R
C US C US
100-120/220-240/380-440 VAC±20%, 3Ph-3Wire, 48-63 Hz 100-120 / 220-240 / 380-440V AC -25%+20%, 48-63 Hz 100-120 / 220-240 / 380-440V AC -25%+20%, 48-63 Hz
Built-in Built In (from 3 Phases) Built In (from 3 Phases)
2 CO 2 CO 2 CO
OV RYB RY R B Y OV
RYB RY R B Y
RYB RY R B Y OV
Unbalance / Unbalance / UV
3 Ph Phase fail
UV
Unbalance / UV 3 Ph N Phase fail
Td : 3.5 Sec.
3 Ph Phase fail
Td : 1-10 Sec.
Td : 1-10 Sec. Td : 1-10 Sec.
Td : 1-10 Sec.
13 14 1 2 13 14 16 17
13 14 16 17
13 15 1 3
13 15 16 18 13 15 16 18
L R L R
O O L
A Y A Y O
D D
A
B B D
N
DOL STARTER
MANUAL MANUAL
RESET RESET
PB PB
D2 VMR 1 D2 VMR 2
C US
Microcontroller design,
SMD Technology,
3-Phase 3-Wire or 3-Phase 4-Wire voltage
Absolute values of UV/OV settings,
monitoring & display, Phase Failure, Unbalance,
Phase Failure, Unbalance, Phase
Phase Sequence, under voltage, Over Voltage,
Sequence, under voltage, Over Voltage
Auto / Manual Reset, Adjustable unbalance trip
Auto/Manual reset, Adjustable settings
setting, Adjustable under/over voltage settings,
for Unbalance, UV/OV and trip delays,
adjustable trip delay, RS232 communication port,
2 CO output relay
2 CO output relay, True RMS Values
Supply Voltage
System
Note: Mention specific voltage 100-120 / 220-240 / 380-440V AC -25%+20%, 48-63 Hz 415 V AC + 20%,-30% (3 Ph-3 W or 3 Ph-4 W selectable)
( Fixed/wide range ) in orderAuxiliary Built In (from 3 Phases) 90-270 V AC/DC, 50 Hz/ (60 Hz) ± 3%
Output Contacts 2 CO 2 CO & RS 232 (optional)
Trip Setting (Volts)
Phase Sequence Yes Yes
Phase Unbalance 4 % - 20 % [Variable] 1 - 20 % (Adjustable)
Under For 380-440V AC 285-425V AC [Variable] 1 - 80V below nominal voltage (for 3 Ph. 3 W)
Voltage For 220-240V AC 165-225V AC [Variable] 1 - 50V below nominal voltage (for 3 Ph. 4 W)
For 100-120V AC 75-115V AC [Variable]
Over For 380-440V AC 400-520V AC [Variable] 1 - 60V above nominal voltage (for 3 Ph. 3 W)
Voltage For 220-240V AC 230-290V AC [Variable] 1 - 25V above nominal voltage (for 3 Ph. 4 W)
For 100-120V AC 105-145V AC [Variable]
7 8 10 11 T2 T2 UV T2
OV UV UB/SP UB/SP UB/SP
LED
T1
9 12 RELAY
7 10
C - NO
T1 = POWER ON DELAY T2 = TRIP DELAY
R L
O
Y A
D
B
R Y B N +VE VE
AUX. SUPPLY
SYSTEM SUPPLY 90-270 VAC/DC
RS232