3.9

Design of Flywing at Median wall portion


Width of the wall

3.9 m

Height of uniform width

2 m

Height of varying width

1.95 m

Thickness of return wall

0.5 m

Unitweight of soil

2
1.9
5

2 t/m3

Coefficient of earth pressure =

0.279

Grade of concrete

25 Mpa

Grade of Steel

Fe500 Mpa

Constants
Modular ratio(m)

10

st

240 Mpa

cb

8.33 Mpa

NA depth factor (n)

0.26

Leverarm factor (j)

0.91

M.R factor(Q)

0.98

Flywing is designed as a cantilever slab panel loaded for soil load and liveload surcharge pressure.
Calculation of Moment at support
Due to Soil load on uniform width
Force due to Soil load

.279* 2* 3.9* 2

4.4 t

Leverarm w.r.t support

3.9*0.5

1.95 m

Moment at support

4.4* 1.95

8.49 tm

Due to Soil load on varying width


Force due to Soil load

.279* 2*0.5* 3.9* 1 =

2.1 t

Leverarm w.r.t support

3.9/3

1.3 m

Moment at support

2.76 tm

2.1* 1.3

Due to Live load surcharge pressure (LLSP) on uniform width


Force due to LLSP

1.2* .279* 2* 3.9* 2 =

5.2 t

Leverarm w.r.t support

3.9*0.5

1.95 m

Moment at support

5.2* 1.95

10.18 tm

Due to Live load surcharge pressure (LLSP) on varying width


Force due to LLSP

1.2* .279* 2*0.5* 3.9* 1.95=

Leverarm w.r.t support

Moment at support

2.5* 1.3

Total moment

1.3 m

3.31 tm

8.49+2.76+10.18+3=

24.74 tm

Moment per metre width

24.74/( 2+ 1.95)

Effective depth required

SQRT(6.26*10^7/(0.98*1000)

Effective depth provided

Area of steel required

Hence provide

3.9/3

2.5 t

.5*1000-50-0.5*Y 1 =
6.26*10^7/( 240*0.91* 442)=
Y 16

150

6.26 tm/m
253 mm
442 mm
646 mm2
1340.41 mm2
HenceSafe