NUT
ESCUTCHEON FOR
FINISHED SURFACE
PLASTIC WATERPROOF
HEAT RESISTANT
CAULKING COMPOUND
MONITOR SWITCH
ASSEMBLY
LOCK WASHER
CONC. WALL
16 MM NPT
CONDUIT
CONC. SLAB
WIRE LEADS
FLAT WASHER
SLEEVE
CONCRETE SLAB
HOOK BOLT
HOOK BOLT
SHAP ON TYPE
ESCUTCHEON PLATE
(FOR FINISHED SURFACE)
CONCRETE SPOUT
NOTE:
10
U-BOLT W/ NUTS
& WASHERS
HORIZONTAL
HORIZONTAL PIPE
(VER. SIZE)
LONGITUDINAL BRACE
FP-06
14
U-BOLT W/ NUTS
& WASHERS
L 50 X 7 X 0-150MM
WALL CONNECTION
IN EXPN SHIELD
1000MM
0.40
OO
R
VICTAULIC
MECHANICAL
TEE OUTLET
6mm X 12.5 mm
X 12.5 mm
AUTOMATIC SPRINKLER
STAINLESS STEEL
PIPE RISER
ANCHORAGE PLATE
VICTAULIC
FIRELOCK RIGID
COUPLING
WATER FLOW
SWITCH
0.40
EXPANSION BOLT
VICTAULIC
MECHANICAL
TEE OUTLET
0.40
400MM
0.40
TEST
DRAIN
VICTAULIC
ALARM TEST MODULE
S/720 (INSPECTOR'S TEST LOOP)
0.40
SL
AB
L
50
VICTAULIC
FLEXIBLE
COUPLING
FLUSHING CONN.
PRESSURE SWITCH
FP-06
VICTAULIC
FLEXIBLE
COUPLING
20
15
FP-06
MAIN DRAIN
RISER
FL
PIPE BRACKET
LONGITUDINAL
FP-06
VICTAULIC
FLEXIBLE
COUPLING
OO
STD. PIPE
CLAMP
FP-06
TEST
DRAIN
0.40
HORIZONTAL PIPE
(VER. SIZE)
VICTAULIC
FLEXIBLE
COUPLING
GROOVED END
PIPE FITTING
SYSTEM
PRESSURE
GAUGE
FIN
U-BOLT W/ NUTS
& WASHERS
CONC. WALL
LADDER RUNG
L 40 X 5MM
2-L 50 X 50 X 7 X 0-75
STEEL PIPE
SCHEDULE .40
ISH
CONCRETE SLAB/BEAM
6MM.THK.
ANGULAR BAR
EXPANSION
BOLTS
NUT
ACTUATOR
COVER
AUTOMATIC RETARDING
CHAMBER
COVER SECURITY
SCREW
500MM
VICTAULIC
MECHANICAL TEE
GATE VALVE
LONG NIPPLE
IN
E
MOUNTING PLATE
UPRIGHT
SPRINKLER
HEAD
DIRECTION OF
FLOW ARROW
B.I. PIPE
A - DEFLECTORS OF SPRINKLER SHALL
BE LOCATED 25 mm TO 305mm
(1" TO 12" BELOW COMBUSTIBLE CEILING
FP-06
22
FP-06
MOUNTING HOLE
VICTAULIC
FLEXIBLE
COUPLING
GASKET
25mm X 13mm
COUPLING REDUCER
SIAMESE TWIN
25mm
DROP NIPPLE
NUT
U-BOLT
25mm X 13mm
COUPLING REDUCER
PENDENT
SPRINKLER
HEAD
ER
VICTAULIC
FLEXIBLE
COUPLING
W
LO
TRUST BLOCK
TRACK BOLT
16
12
FP-06
900 mm
WA
CEILING
21
FP-06
FP-06
FP-06
HOUSING
PIPE
150 mm
SUPPLY PIPE
C
L
VICTAULLIC
COUPLING
2 ELLS
EXTENDED COVERAGE
SIDEWALL
TYPE SPRINKLER HEAD
8"
17
'B'
'A'
FELTON WHEEL
NIPPLE 'E'
2 ELL LENGHTS
8 1/2" FOR 3" PIPE
7 1/2" FOR 2 1/2" PIPE
'C'
EII
60
FIRE HOSE
DOUBLE JACKET
NORMAL
POSITION
WALL PLATE
STRIKER ASSEMBLY
GONG
VERTICAL
MOVEMENT
ELL
FLOOR LINE
VIBRON NEOPENE
50 DURA FREE HT.2"
REINFORCED
CONCRETE FLOATING
AIR SPACE
F.F.L.
INCLUDING
FRAME
TO CB
'D'
ELEVATION
ELL
SUPPORT
PIPE
13
9
25 50
(SIZE OF CABINET
INCLUDING FRAME)
50 25
25 X 50MM ANODIZED
ALUMINUM FRAME FOR
SURFACED MOUNTED
CABINET
2MM THICK
CLEAR GLASS
SURFACED MOUNTED
SIZE OF
CABINET
SIZE OF CABINET
INCLUDING FRAME
SURFACE MOUNTED
900mm
1000mm
800mm
900mm
700mm
800mm
FLOOR SLAB
25
FP-06
GONG BOLT
50
RECESSED MOUNTED
HOSE VALVE
EII
10MM
50
25 25
25 X 50MM ANODIZED
ALUMINUM FRAME FOR
RECESSED MOUNTED
CABINET
RECESSED MOUNTED
BODY COVER
C
25 25
IDENTIFICATION SIGNS
FP-06
25
(SIZE OF CABINET)
SIGHT GLASS
VICTAULIC
FLEXIBLE
COUPLING
25
(INCLUDING FRAME)
PLAN
FP-06
DRIVE SHAFT
PRESSURE GAUGE
NORMAL POSITION
8"
50
50 25
\\192.168.5.32\residential projects\FILINVEST BINONDO SHOWROOM\DRAWING IN\032715 One Binondo Showroom frm flfa\FIRE PRO\FP-06_MISCDET.dwg, 3/31/2015 6:16:13 PM, DWG To PDF.pc3
SUPPLY PIPE
ORDINARY
SIDEWALL
TYPE SPRINKLER HEAD
50
SEMI-AUTO HOSE
RACK EPOXY PRIMED
FIRE RED BAKED
ENAMEL FINISH
C
L
(SIZE OF CABINET
INCLUDING FRAME)
PIPE CLAMP
50 25 25
'B'
'A'
BRANCH LINE
REGULAR RECESSED
PENDENT
TYPE SPRINKLER HEAD
VICTAULIC
FLEXIBLE
COUPLING
(SIZE OF CABINET)
REGULAR
UPRIGHT
TYPE SPRINKLER HEAD
FP-06
FP-06
VICTAULIC
COUPLING
25 25 50
FP-06
VICTAULIC MECHANICAL
GROOVED END COUPLING JOINT
25 50
VICTAULIC
FLEXIBLE
COUPLING
24
ROOF MANIFOLD
25 175
FIRE EXTINGUISHER
23
PIPE HANGER
(INCLUDING FRAME)
25 175
FL
VICTAULIC
FLEXIBLE
COUPLING
900 mm
OF
U
50 PPE
0
R
800MM
0.40
AB
EXPANSION
BOLTS
6MM.THK.
ANGULAR BAR
VICTAULIC
FLEXIBLE
COUPLING
SL
CONC. WALL
HORIZONTAL PIPE
(VER. SIZE)
FP-06
FP-06
BO
TT
OM
19
FP-06
FP-06
U-BOLT W/
NUTS &
WASHERS
IDENTATION
HOOK FACES
OUTWARD
HOOK FACES
INWARD
BOTTOM OF BEAM
6MM.THK.
ANGULAR BAR
PIPE
(VER. SIZE)
LOCK NUT
INNER LOCKNUT
MOUNTING BRACKET
CONCRETE WALL
6MM.THK.
ANGULAR
BAR
WOOD
STIFFNER
'W' x 'T'
UNISTRUT VERTICAL
PIPE CLAMP OR
APPROVED EQUAL
HORIZONTAL PIPE
(VER. SIZE)
PLASTIC WATERPROOF
HEAT RESISTANT
CAULKING COMPOUND
NOTES:
EXPANSION
BOLTS
6MM.THK.
ANGULAR BAR
'W' x 'T'
UNISTRUT VERTICAL
PIPE CLAMP OR
APPROVED EQUAL
HORIZONTAL PIPE
(VER. SIZE)
EXPANSION
BOLTS
CONC. SLAB
EXPANSION
BOLTS
6MM.THK.
ANGULAR BAR
PIPE
FP-06
18
FP-06
FP-06
FP-06
SEAL
STRUCTURAL
DESIGNER
ELECTRICAL
MECHANICAL
670
P.M.E
3554
2282035
100-355-030
01-06-2015
MECHANICAL ENGINEER
REG.NO.
REG.NO.
2691
REG.NO.
REG.NO.
PTR.NO.
PTR.NO.
PTR.NO.
PTR.NO.
TIN.
TIN.
DATE:
DATE:
TIN.
TIN.
2282033
253-866-002
DATE:
DATE:
01-06-2015
MISCELLANEOUS DETAILS
SHEET
CONTENTS
FERDINAND L. FIGUEROA
SHEET NO.
1704
0181375
123-451-284
01-07-15
ONE BINONDO
MIXED-USE DEVELOPMENT
LOCATION: MORIONES ST. COR. JUAN LUNA ST. BINONDO, MANILA
DATE
SCALE
CADD
RVLJJDIDDRAG
REVISION
CHECKED
FLFA
PROJECT NO.
APPROVED
FLFA
NTS.
FP