Sie sind auf Seite 1von 2

A

DLV A3

VM L

VML

DLV A3

VRF P

OUT IN

9
J

VRFP

IN

4
VMP/ S

VMD

VMD

VMP/S

1
10

VSMA

MAN

10

ML

Valve 1 , 1

Valve 2
Y-

C
UP

chg 0,02s

DN
G

OFF

[G]

[G]

3010/S

(J =1:1)

ML

[F]

[G]

VS MA

ML

[C]
3

[ B]

[F]

VMP/S

VS 1
1

VS MA

VSMA

VMD

VML

[A]
S

VRFP
9

(Y-/S CC)

VB

[E]

VRF

DAL

[H]

[F]

VR2

ML
[F]

[L]

VC 3006/B

[F]

VS10

R/S2

[H]

VRP

8
2

VR

[E]

VMP

ON

VML

VMD

VML

H
I

Y 1,5s

0,30,5s

E
D

PAM
PAM

R/S1

[L]

[H]

REMOT E

[F]

VR a

10
VR1

Ma

DLV

ISP

MAN

VALVE 3010/S + DLV A3


HYDRAULIC CIRCUIT

TABLE : 04.008.EN
DATE : 02.04.2014

VER.: D
1/2

Pmax

P min

OLD

ABBREVIATIONS FOR ALL THE GMV HYDRAULIC SCHEMES


1
2
3
4
5
6
7
8
9
10
3010, 3010EN

Adjustment screw : safety valve (pressure


relief)
Adjustment screw : levelling speed
Adjustment screw : deceleration (upward /
downward)
Adjustment screw : acceleration (upward)
Shut-off valve / Screw for rupture valve test
Shut-off valve for pressure gauge exclusion
Adjustment screw : ram pressure (only 2:1
acting jacks)
Adjustment screw : high speed
Adjustment screw : downward speed
compensation
Adjustment screw : safety valve (PAM)
Valve 3010 (complete)

BOX
C1
C2
C3
C4
CARD
CHG
D

Interface box (Valve / Control panel)


VRP chamber
Inlet chamber
VB outlet chamber
VRP pilot spool chamber
Electronic card
Exchange

DAL
DIR
DLV A3
DN
FLT
ISP
J
J 1:1
K
M, Ma
M1
MAN
ML
MP
MPS
NGV
NGV-A3
OFF
OLD, OVL
ON
OPP

Auxiliary levelling device


Direct
DLV A3 Valve
Downward
Filter
Inspection gauge fitting
Jack
Direct Jack 1:1
Non-return valve
Motor
VRP spool
Pressure gauge
Manual lowering button
Motor / pump
Maximum pressure spool
NGV Valve (Complete)
NGV A3 Valve (Complete)
Powered off
Full load pressure limit switch
Powered
MPS pilot valve

Downward signal

VALVE 3010/S + DLV A3


HYDRAULIC CIRCUIT

VRP pilot spool

PAM
Pmax

Hand pump

Pmin
PT
R/S
RDY

minimum pressure limit switch


Pressure transducer
Ball valve (1) / Silencer (2)
Ready - Ready signal (card output to control
panel)
Delay

RIT
RO

Maximum pressure limit switch

Oil heating resistance

RT
RUN

Motor thermistors
Run - Start signal (card output to control
panel)
S1 (VRP) VRP closing control sensor
S2 (VBC) VB closing control sensor
S3 (VBO) VB opening control sensor
SCC
Starting Current Control
SM
Stepping motor
TO
Oil thermostat
TT
Temperature transducer
UP
Upward / Up - upward starting command
(card to control panel)
V0
Speed : high
V1
Speed : medium
V2
Speed : inspection
V3
Speed : fine levelling
VAL
Valve (Valve only)
VB
Main flow adjustment valve
VC
Rupture valve
VMD
Downward solenoid valve
VML
Levelling solenoid valve
VMP
Starting solenoid valve (Y-D / SCC)
VP
Pressure valve
VR
Non-return valve (flow outlet)
VR1
Non-return valve (inlet)
VR2
Non-return valve (outlet)
VRa
Non-return valve (flow outlet) - Auxiliary
VRF
Flow regulation valve
VRFP
Ausiliary flow regulation valve
VRP
Non-return valve - controlled
VS
Pilot valve, Upward signal [NGV]
VS1, VS10 Pressure safety valve
VSMA
manual / electrical Lowering valve
Y, , Y- Star, Delta, Star-Delta

TABLE : 04.008.EN
DATE : 02.04.2014

VER.: D
2/2

Das könnte Ihnen auch gefallen