\ _ Application ‘The relay ype ICM (this designotionis used henceforth {or simplicity’sseke to denote all four variants ICM 2, 1CM21, ICM 22 and ICM 23) isan overcurrent relay with ‘aninvorso-time characteristic. That means to say, its tripping time is shorter, the greater the fault current. As secondary relay itis fed by current transformers. Itis used to protect parts of electrical installations and simple line systems against short circuits. Except on teed lines the ICM 2 relays can be used together with directional relays forthe protection of ring-main systems. For the protec- tion of soidly earthed systems against earth faults there are relays with current settings up t00.2 Aavailable. ‘The relay can be employed in all situations where delayed fertuption of short circuits is required, provision also being made forinstantaneous tripping ata set maximum current. Main features ~ Reliable, robust Fort gearing or coupling + Range of time setting 10-100% (see current/time characteristic) — Range of current setting 1:4, adjustablein 7 steps by means of non-interrupting setting switch — High resetting current, atleast 96% of relay setting = Max. overrun time of 0.02 = Temperature-compensated measuring system = Instantaneous maximum-current trip with own con- tact and own visual signal ~ Instantaneous maximum-currenttrip, continuously adjustable between 10/, (relay setting) and infinity ~ Separate double-pole tripping contactor with indicator, forhigh contactrating — Lowintemal consumption ~ Plug-in active part, the ct. connections being auto- matically short-circuited when the relay is withdrawn ~ Tropicalized design ss measuring system without Neale cca raisin Fig, 1 ~Inverse-time overcurrent rele, type1CM 2h | { + © Design and principie Thg sla} Comprises a temperature-compencated Ferraris rintasuringsystom which equirosno coupling. gearing orhinged amature. The 1 mm thick Fears Use of Sluminiumis drawn by afecal spring, arecallrope anda worm againstastopon tho time adjustment ise, ondis thus haldin ts postion of ext. The worm compensates forany chengein the force ofthe recall spring within an angle of rotation ofthe Ferrarisise of 320" Thus the fecal torque ramainseonatant. The driving forquo.and withitthe angular spoed of the Ferrarisciscare constant Asa esultthe current/ime characteristics ofthe reloy are exactly proportional The relays are manufactured with vatiouscurret/time charactoristies and also for 50 and 80 Hz (Fig. 7). Th characteristic determines the type designation ef the pariculr relay. Tho cusent col ofthe diving slsnoid nds 14 tappinas, comesponding 1 the seven sagesaf he non-interupting setting swtch for thewelayeureent ‘Theadjustmentofthe time setting dse determines the angle of rotation ofthe Ferraris die priorto contact making ‘The braking magnet consisting of a pair of cross- ‘magnetized magnets determines the speed of rotation ofthe Ferraris disc at a given current. | ¢ Fig.2~ Aetivepattof hesetey CM 2h 4+ Coittermina!s othe indieating contactor 2 lndistorbuiton ol delayed inp 8 = Comactsctthoindicatngelvose-contactor 4 = Tame sting al ‘5 = Moving ctect pin ofthe lay timo contact 6 = Sprunghlserofrelay une comnact 7 = Indicator button ofinetamaneous tip 8 = Drumforsoting the netantancous tp 8= Damping magnet 10 Seateso1adusting damping 11> Tomperstue compensating an 12> Peinarof anni 13 Locking nm 14 © Switch fr sing relay pick-up ewe 15» Sie Toredusting eunant 16 = Scaloformarhing actoryadjustnant of site 17 Dining magi, 18 = Catone diving magnet 18 = Fonaredice . 20 = Testeontacis Fig. ~ Internal crite of lays type ICM, indicating contactor with eutrent coi Fig. 4 ~ ltomal crit of eays type IC, indesting contactor with voltage cit Logend orig. ana eating ipting contactor hortigswich F = Breakartipco T = Signal button ofingicaing contsetor X= Signal button alistantaneour ip ‘The armature of the instantaneous maximum-curront release is drawn by the leakage flux of the driving magnet, acting against the force of a spring, The maxi mum current setiing may be adjusted at the cylinder. When setto infinity (.») the release is blocked, The release has its own contact (normally open) anda signal button which can be reset from outsido, ‘The indicating release contactor has two separate con- tacts with double interruption and a signal button which springs out when the relay tripsand can be reset by hand. The coil of the indicating contactor may bea current coil (Fig. 3) energized by the current which ‘rips the breaker ‘This tripping command is emitted by the main relay and applied direct to the breaker. One of the relay contacts has to be able to make the full ripping current of the breaker. Not until oftor about 25 ms, when the indicating contactor has picked up, does the latter short-circuit tie relay contacts, For this contactor only normally open contacts are permissible, because only then can the intemal constumption and thus the resistance of the contactor coils be kept small ‘The contactor coil may also be a voltage coil (Fig. 4). When the relay picks up, the contactor coilis connected to the auxiliary voltage by one of the two relay contacts, ‘the breaker tripping cugentis handled by the indicating contactor, One ofits wo contacts may bea normally closed contact. Itis possible toincorporate two separate indicating ‘contactors, one fr the inverse-time tripping, the other forthe instantaneous maximum-current tripping. “Tho active part ofthe relays plugged into the dust-tight casing. Having reset the signal buttons, the lid can be opened. The locking arm, normally vertical, can then be swung down, in which position the active part ofthe relays already disconnected from the eadsand the ct. Connections automatically short-circuited. Therelay can now be entirely withdrawn trom ts casing, forinstance fortesting orrepair. Designation of types Type of relay. Current/time characteristic 50H2 | 6OHe iGM2 Inversotimerelsy | Fig.7a__| Fig. 7e ICM21 Inverse time relay, British Standard | Fig.7 | Fig. 7 1CM22 Veryinversetime — | relay Fig.7¢ | Fig. 74 1cM23 Very inverse time relay, specialtype | Fig.74_| Fia.70 ‘The relay casing can be supplied for flush mounting in a switchboard. By pushing the mounting frame to the rear of the relay, surface mounting with rear connection is ‘made possible. For surface mounting with front con~ ection an additional adapter frame with a set of tet nalsisnceded (see Figs. page8). Alternative models, Suffix © suffix to type designation Indicating contactor voltage coilfora.c. | % Indicating contactor current coil ford. Rolay with two indicating contactors With pilot iamps for the coils and voltage, paralfol to the relay contacts, which light upas{ongasthe tripping circuit isnot interrupted by a fault and the relay isin its position of est With instantaneous maxinum-cursent trip With starting contact (instead of instantaneous Test terminals, type suffix ‘p’ Atthe front of the relays are the easily accessible test terminals 20 (Fig.2). When terminals 11 and 12 are provided for relays with two indicating contactors, test terminals can only be provided for relay terminals 1-10. Circuit 11~12 (signal for instantaneous trip) ist therefore not equipped with test terminals. For the special model with test terminals a separate test plug (Fig. 5) can be supplied. For testing, itis inserted beneath the pair of lugs in the casing, as shown in Fig.6, and then the drawout armis lowered. First of all the shorting switches close, then the connections to the terminals of the casing are interrupted and finally the test terminals are connected to the terminals of the plug, The test plug is supplied with 3 mof cable but without any terminals on the supply side, as they have to match those of the test set, Fig. G-- Inverse-tine overcurrent ilay type ICM 2 with ost pag incated, lacking aim lowered and relay inthe postion fo esting | Techpical data Current range: Relay pick-up current /adjustable to: 40/16 A 40 50 60 80 10 12 16 A 25/10 A 25 30 40 50 60 80 10 A 1.5/ 6.0 15 20 25 30 40 60 60 A 1.0/4.0, 10 125 15 20 25 30 40 A 08/ 3.24, 08 10 12 16 20 24 32 A 705/20 05 06 08 10 12 15 20 A “O27 OBA 02 025 03 04 05 06 O8 A Consumption at pick-up current: 50 Hz 35 36 37 39 42 44 48 VA 60 Hz 4142 43 46 49 52 56 VA Rated frequency ‘50 or 60 Hz Permissible sustained current Short-circuit strength: thermal (for 1's) dynamic Timing element 2x setcurrent 100 minimum set current 800% minimum set current Picl_ >eurrent/, max. error 24% Time-lag ‘as per characteristic, Fig. 7 Max. error upto 2x: = 10% to Axi 7% 4t020x/: = 5% Rosette when tme-iag sot 0 100% approx, 955 Max. overtun time ; 0.025 Drop-outratio ‘in, 0.96 — - Contact break ime aftertipping | - Instantaneous maximum-éurrent trip Sotting range fortypeICM2_andICM21 type ICM 22 and ICM 23 max. 0.085 2.5-10*/and « 3 -10x/and Max—ror | + 10% Opef@fing at twice set current orover Drop-out current =O. 03s approx. 0.08 s plus operating ime of indicating contacto approx. 1.2-2.5% pick-up current/ of relay depending on setting Starting contact (instead of instantaneous-current trip) Pick-upvaue max. 1.25%7 — ; ‘min. 0.96%) — aaas Drop-out value 1 Please quote wien ordering Ordving lasructions 4. Type with sti 2 Curent ange 8. tod frequiney 4 Ausary vatago 5. Diagam No. . 6. Awol mounting 4 Indicating contactor, Indicating contactor with current coil (fordc.only) (2) Ontapping 0.2 eoilresistance approx. 1ohm OO) permissible curent0.2-1.2.A Ontapping 1.0 Eoiresstance approx. 0.64 ohm Nature free contact hoxmally open (must notbe changed o N/C) indicating contactor with voage col Rated auxiliary voltage: ford.c. 6, 24, 36, 48, 60, 100, 110, 125, 145, 200, 220, 250V . fora.c. 6, 24, 48, 110, 127, 220, 250, 380 V (state frequency) Nominal consumption onde.appiox 2W ona. approx. VA Nature of ee contacts Znormaly open (ort N/Cand1 N/O) Operating time approx.0.035 Contact ratings ‘The contacts of the relay and of the instantaneous trip, when connected asin Fig. 3, are capable of making 30 Aat a maximum ‘0f 250 V and of carrying this current until they are short- by the normally open contact of the indicating tripping contactor. | ‘They must be interrupted in every case by an auxiliary contact of | the circuit-breaker. Indicating contactors with voltage coil (Fig.4) are actuated permissible current 1.0-20 | | hout difficulty by both contacts of the relay at voltages up to - ( i. . 250V. |" Contactor contacts: sustained current max 10 | making current max 30 Maximal break current Voltage 50 Hza.c. resis- Dc. ‘ tive'and inductive, | resistive inductive | pf. = 0.3 L/R=15ms 1 Teontact 2200 aA 8A | Tov 204 BA 3A 24-60 6A 765A i contacts in series 220 = 6A 35A a itov = BA 10 A ‘These are max. valued for a small number of operations. To attain a contact life of about 10000 operations, the; should be reduced to about 60%. General items Test voltage _ - 2000, 4 min - ‘Weight with one indicating contactor 38kg é Weight with two indicating contactors 4.0kg Weight of test plug with 3 mcablo 1.8k9 Circuit diegrams see page 2 Dimensions 1 Please quote when ordoing c a oO ¢ ) oz ot ioe 9 om 3 ° Oth i? ¥ j T ; | raat fe A y Stel srt] ay Sf + 4 ly ] oh—h 4 | | + —19, j s ; got or ba wy aeseaur Aon 5 mo 1 te» eo one + mo 8 t% 6 + 6 | ima le lz | ey ae ape s , see ; , | a I P : lez woleuas zz wot 2¢an wot aah, + | 014. ! ' Hos 2405 3H 09 908 pa t 00462) | oor sersun | oor 6e-ou 1 H . a 1 If 1 i a a Pontaét arrangements, type designations and circuit diagrams of inverse-time overcurrent relays. «“typoICM2 for flush er surface mounting, with rear connections Rotay Withouttestterminals | With testterminals vo) Tee Design Diagram | Sufix | Diagram w@ Tripping circuit Contactor No. totype | No. Coil { Contacts | for | @ Relay with 1 contactor having voltage coil ICM2— | Timeandmaximum | dc. e ICM21 | curentcontact 2x AK 421255 | P AK 421256 1cm22 | bothactuatethe ae Z 2b i 1cM23 | same contactor de. = P teHty AK 421 259 ‘AK 421260 ac. a = Max, curren le. - eee Pslllox axa2i267 LP___| ax az 268 a6. @ = 88 axtty = Kazi 269 |P AK 421.270 ac, @ = With pitotlamp. Tima | ge. a it CL ene mesegumcunent 2x AK 421263 AK 421 264 thesamecontactor | 8 em amp Withsioring contact | dw ie = 7 instead of maximum- 2x ! axaai27 AK 421.272 current contact, ac. 20 ‘0p Relay with 1 contactor having current f tem2h | Timeand maximum T iz i 1eM21n | current com icntazh | both actuate the aK 421251 aKazi252 ICM23h | same contactor aq |ue . de i Maximim-current contactin separate AK 421 265 AK 421 266 circuit (7 Relay with2 contactors having voltage coils iCM2k | Timaandmaximum- | dc. = > _ ICM21k | current contact 22x ———| AK 421275 |. AK 421276 1CM22k | both actuate the ac. a 2p temzax | sameconecer [ae iE le} 2-(1x+19) ——} aK 421277 AK 421278 a ae. a 2 ‘With staring contact | dc. @ o- instead of mezximum- FU] 22x |2 _| akazra7a | °P___| axazt280 ‘current contact je ao “| a0p ae ° | 2x (1x19) axazize1 | °P__| axazi2e2 CC 2 | ap | With siaiting contact op bai instead of maximum 22x AK 421283 | OP AK 421204 current contact for ak, op . combination with, 5 i e 7 Girectionatelay | xt (1x19) axazi28s |2P___| axazi 286 20 aop. ‘Dx-~ Moke contact = Breik contact i {© Pleasa quot wlien ordering . Dimensiohs ‘i — + Y Fig.T0 - Surface mountng,frontconnection fi BROWN BOVERI Printdin Swern (7502-3700-0) ‘Clssenion Ho, 071401 Fig. 8 ~ Surface mounting, rearconnection 4 Fig. 11 ~ Holoin panel forrlasin Fig. Band my tegen >} ‘Aa. = Roorteminals M5, number according to circuit agram, max 18 ‘Aat = Frontierminls M®, number accoring to ceuit degra. max 18 Fo = Hoteinpanat ‘Mounting fame, modification foreurlace mounting possible Frsingscrew its Ge © Eonhingserew MS *)" © Upperterminal Bock, only when more than 12teninals © = 27 mmforpanets upiot7 mm thick ‘ommfor panels up to 40 mmthick Dimensions in miiretors (binging) BBC Brown, Boveri & Company, Ltd., CH-5401 Baden/Switzerland : Division € a

Das könnte Ihnen auch gefallen