SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

07/14/2015 07:28:11 AM

FB12 - <offline>
"ABB_RPBA_01"
Name:
Author: TQuy

Family:
Version: 0.1
Block version: 2
05/25/2015 03:57:35 PM
Time stamp Code:
05/25/2015 03:57:35 PM
Interface:
Lengths (block/logic/data): 01912 01470 00020

Name

Data Type

IN

Address

Initial Value

Comment

0.0
Drive_Address

Int

0.0

Drive Address in an INT- See hardware config.

PPO

Int

2.0

PPO 1-5

On_Off

Bool

4.0

FALSE

ON OFF Command Cw bit0

Off_2_Coast

Bool

4.1

FALSE

OFF 2 Coast Cw bit1

Off_3_Q_Stop

Bool

4.2

FALSE

OFF 3 Quick Stop Cw bit2

Enable_Operation

Bool

4.3

FALSE

Enable Drive Operation Cw bit3

Ramp_Gen_Enable

Bool

4.4

FALSE

Ramp Generator Enable Cw bit4

Ramp_Gen_Hold

Bool

4.5

FALSE

Ramp Generator Hold Cw bit5

Ramp_Gen_Setpoint

Bool

4.6

FALSE

Ramp Generator Setpoint Cw bit6

Fault_Reset

Bool

4.7

FALSE

Fault Reset Cw bit7

Inching1_Jog

Bool

5.0

FALSE

Jog Command- ONLY USED WITH ACS800 Cw bit8

Inching2_1

Bool

5.1

FALSE

Remote Comms- Must be ON Cw bit9

Remote_Coms

Bool

5.2

FALSE

CtrWord bit10

Ext

Bool

5.3

FALSE

CtrWord bit11

CW12

Bool

5.4

FALSE

CtrWord bit12

CW13

Bool

5.5

FALSE

CtrWord bit13

CW14

Bool

5.6

FALSE

CtrWord bit14

CW15

Bool

5.7

FALSE

CtrWord bit15

Speed_Reference

Word

6.0

W#16#0

Speed Reference- -20000 to 20000

PZD_3_WRITE

Word

8.0

W#16#0

PZD Write

PZD_4_WRITE

Word

10.0

W#16#0

PZD Write

PZD_5_WRITE

Word

12.0

W#16#0

PZD Write

PZD_6_WRITE

Word

14.0

W#16#0

PZD Write

PZD_7_WRITE

Word

16.0

W#16#0

PZD_8_WRITE

Word

18.0

W#16#0

PZD_9_WRITE

Word

20.0

W#16#0

PZD_10_WRITE

Word

22.0

W#16#0

OUT
Actual_Value_0_100_Perct

0.0
Real

24.0

0.000000e+000

Out --100 Percent to 100 Percent

Drive_Running

Bool

28.0

FALSE

Out- Drive Running Sw bit0

Drive_ReadyRun

Bool

28.1

FALSE

Out- Drive Faulted Sw bit1

Drive_ReadyRef

Bool

28.2

FALSE

StatusWord bit2

Tripped_Out

Bool

28.3

FALSE

StatusWord bit3

Off2_out

Bool

28.4

FALSE

StatusWord bit4

Off3_out

Bool

28.5

FALSE

StatusWord bit5

Sw_on_inhb

Bool

28.6

FALSE

StatusWord bit6

Alarm_out

Bool

28.7

FALSE

StatusWord bit7

At_sp

Bool

29.0

FALSE

StatusWord bit8

Remote_out

Bool

29.1

FALSE

StatusWord bit9

Above_Li

Bool

29.2

FALSE

StatusWord bit10

ExtCtrLocal

Bool

29.3

FALSE

StatusWord bit11

Page 1 of 17

SIMATIC

Name

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

Data Type

Address

Initial Value

07/14/2015 07:28:11 AM

Comment

ExtRunE

Bool

29.4

FALSE

StatusWord bit12

SW13

Bool

29.5

FALSE

StatusWord bit13

SW14

Bool

29.6

FALSE

StatusWord bit14

SW15

Bool

29.7

FALSE

StatusWord bit15

Main_Actual_Value

Word

30.0

W#16#0

Out -Main Actual Value- -20000 to 20000

PZD_3_READ

Word

32.0

W#16#0

Out- PZD From Drive

PZD_4_READ

Word

34.0

W#16#0

Out- PZD From Drive

PZD_5_READ

Word

36.0

W#16#0

Out- PZD From Drive

PZD_6_READ

Word

38.0

W#16#0

Out- PZD From Drive

PZD_7_READ

Word

40.0

W#16#0

PZD_8_READ

Word

42.0

W#16#0

PZD_9_READ

Word

44.0

W#16#0

PZD_10_READ

Word

46.0

W#16#0

IN_OUT

0.0

STAT

0.0

INCHING1

Bool

48.0

FALSE

DRIVE BIT 8 -ATTENTION-THE CONTROL WORD HAS BEEN


EXCHANGED TO LINE UP WITH

INCHING2

Bool

48.1

FALSE

DRIVE BIT 9

REMOTE_COMMAND

Bool

48.2

FALSE

DRIVE BIT 10

Ext_1

Bool

48.3

FALSE

DRIVE BIT 11

NA12

Bool

48.4

FALSE

DRIVE BIT 12

NA13

Bool

48.5

FALSE

DRIVE BIT 13

NA14

Bool

48.6

FALSE

DRIVE BIT 14

NA15

Bool

48.7

FALSE

DRIVE BIT 15

OFF_1

Bool

49.0

FALSE

DRIVE BIT 0

OFF_2

Bool

49.1

FALSE

DRIVE BIT 1

OFF_3

Bool

49.2

FALSE

DRIVE BIT 2

OPERATION_ENABLE

Bool

49.3

FALSE

DRIVE BIT 3

RAMP_GEN_ENABLE_1

Bool

49.4

FALSE

DRIVE BIT 4

RAMP_GENERATOR_HOLD

Bool

49.5

FALSE

DRIVE BIT 5

SETPOINT_ENABLE_COMMAND

Bool

49.6

FALSE

DRIVE BIT 6

FAULT_ACK_COMMAND

Bool

49.7

FALSE

DRIVE BIT 7

SPEED_COMMAND_PZD2

Word

50.0

W#16#0

WRITE VALUE

ACT_VALUE_WRITE_PZD3

Word

52.0

W#16#0

WRITE VALUE

ACT_VALUE_WRITE_PZD4

Word

54.0

W#16#0

WRITE VALUE

ACT_VALUE_WRITE_PZD5

Word

56.0

W#16#0

WRITE VALUE

ACT_VALUE_WRITE_PZD6

Word

58.0

W#16#0

WRITE VALUE

ACT_VALUE_WRITE_PZD7

Word

60.0

W#16#0

ACT_VALUE_WRITE_PZD8

Word

62.0

W#16#0

ACT_VALUE_WRITE_PZD9

Word

64.0

W#16#0

ACT_VALUE_WRITE_PZD10

Word

66.0

W#16#0

AT_SETPOINT

Bool

68.0

FALSE

READ VALUE

REMOTE

Bool

68.1

FALSE

READ VALUE

ABOVE_LIMIT

Bool

68.2

FALSE

READ VALUE

Ext_Local

Bool

68.3

FALSE

READ VALUE

Ext_RunE

Bool

68.4

FALSE

READ VALUE

NU13

Bool

68.5

FALSE

READ VALUE

NU14

Bool

68.6

FALSE

READ VALUE

NU15

Bool

68.7

FALSE

READ VALUE

-BITS IN THE DRIVE

Page 2 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

Name

Data Type

Address

Initial Value

Comment

READY_ON

Bool

69.0

FALSE

READ VALUE

READY_RUN

Bool

69.1

FALSE

READ VALUE

READY_REF

Bool

69.2

FALSE

READ VALUE

TRIPPED

Bool

69.3

FALSE

READ VALUE

OFF2

Bool

69.4

FALSE

READ VALUE

OFF3

Bool

69.5

FALSE

READ VALUE

SWITCH_ON_INHIB

Bool

69.6

FALSE

READ VALUE

ALARM

Bool

69.7

FALSE

READ VALUE

READ_ACT_VALUE_HIW_PZD2

Word

70.0

W#16#0

READ VALUE

READ_ACT_VALUE_HIW_PZD3

Word

72.0

W#16#0

READ VALUE

READ_ACT_VALUE_HIW_PZD4

Word

74.0

W#16#0

READ VALUE

READ_ACT_VALUE_HIW_PZD5

Word

76.0

W#16#0

READ VALUE

READ_ACT_VALUE_HIW_PZD6

Word

78.0

W#16#0

READ VALUE

READ_ACT_VALUE_HIW_PZD7

Word

80.0

W#16#0

READ_ACT_VALUE_HIW_PZD8

Word

82.0

W#16#0

READ_ACT_VALUE_HIW_PZD9

Word

84.0

W#16#0

READ_ACT_VALUE_HIW_PZD10

Word

86.0

W#16#0

Ret_Val_Error1

Int

88.0

Ret_Val_Error2

Int

90.0

addresstemp

Word

92.0

W#16#0

TEMP

07/14/2015 07:28:11 AM

0.0

Block: FB12

Network: 1
L
T

#Drive_Address
#addresstemp

Network: 2

#Drive_Address
#addresstemp

-- Drive Address in an INT- See hardware config.

PPO1

CMP ==I
#PPO
PPO 1-5
#PPO IN1

SFC14
Read Consistent
Data of a Standard
DP Slave
"DPRD_DAT"
EN
ENO
#addresste
mp
#addresste
mp LADDR

#Ret_Val_E
rror1
#Ret_Val_
RET_VAL Error1

1 IN2
P#DIX
68.0 BYTE
RECORD 4

Page 3 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

Network: 3

07/14/2015 07:28:11 AM

PPO2

CMP ==I
#PPO
PPO 1-5
#PPO IN1

SFC14
Read Consistent
Data of a Standard
DP Slave
"DPRD_DAT"
EN
ENO
#addresste
mp
#addresste
mp LADDR

#Ret_Val_E
rror1
#Ret_Val_
RET_VAL Error1

2 IN2
P#DIX
68.0 BYTE
RECORD 12

Network: 4

PPO3

CMP ==I
#PPO
PPO 1-5
#PPO IN1

SFC14
Read Consistent
Data of a Standard
DP Slave
"DPRD_DAT"
EN
ENO
#addresste
mp
#addresste
mp LADDR

#Ret_Val_E
rror1
#Ret_Val_
RET_VAL Error1

3 IN2
P#DIX
68.0 BYTE
RECORD 4

Network: 5

PPO4

DP Read Block

CMP ==I
#PPO
PPO 1-5
#PPO IN1

SFC14
Read Consistent
Data of a Standard
DP Slave
"DPRD_DAT"
EN
ENO
#addresste
mp
#addresste
mp LADDR

#Ret_Val_E
rror1
#Ret_Val_
RET_VAL Error1

4 IN2
P#DIX
68.0 BYTE
RECORD 12

Page 4 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

Network: 6

07/14/2015 07:28:11 AM

PPO5

DP Read Block

CMP ==I
#PPO
PPO 1-5
#PPO IN1

SFC14
Read Consistent
Data of a Standard
DP Slave
"DPRD_DAT"
ENO
EN
#addresste
mp
#addresste
mp LADDR

#Ret_Val_E
rror1
#Ret_Val_
RET_VAL Error1

5 IN2
P#DIX
68.0 BYTE
RECORD 20

Network: 7

Network: 8
Drive Running Bit

#READY_ON
READ VALUE
#READY_ON

#Drive_Run
ning
OutDrive
Running
Sw bit0
#Drive_
Running

Network: 9
Drive Faulted bit

#READY_RUN
READ VALUE
#READY_RUN

#Drive_Rea
dyRun
OutDrive
Faulted
Sw bit1
#Drive_
ReadyRun

Page 5 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

07/14/2015 07:28:11 AM

Network: 10

#READY_REF
READ VALUE
#READY_REF

#Drive_Rea
dyRef
StatusWord
bit2
#Drive_
ReadyRef

Network: 11

#TRIPPED
READ VALUE
#TRIPPED

#Tripped_O
ut
StatusWord
bit3
#Tripped_
Out

Network: 12

#OFF2
READ VALUE
#OFF2

#Off2_out
StatusWord
bit4
#Off2_out

Network: 13

#OFF3
READ VALUE
#OFF3

#Off3_out
StatusWord
bit5
#Off3_out

Network: 14

#SWITCH_ON
_INHIB
READ VALUE
#SWITCH_
ON_INHIB

#Sw_on_inh
b
StatusWord
bit6
#Sw_on_
inhb

Page 6 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

07/14/2015 07:28:11 AM

Network: 15

#ALARM
READ VALUE
#ALARM

#Alarm_out
StatusWord
bit7
#Alarm_out

Network: 16

#AT_SETPOI
NT
READ VALUE
#AT_
SETPOINT

#At_sp
StatusWord
bit8
#At_sp

Network: 17

#REMOTE
READ VALUE
#REMOTE

#Remote_ou
t
StatusWord
bit9
#Remote_
out

Network: 18

#ABOVE_LIM
IT
READ VALUE
#ABOVE_
LIMIT

#Above_Li
StatusWord
bit10
#Above_Li

Network: 19

#Ext_Local
READ VALUE
#Ext_Local

#ExtCtrLoc
al
StatusWord
bit11
#ExtCtrLoc
al

Page 7 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

07/14/2015 07:28:11 AM

Network: 20

#ExtRunE
StatusWord
bit12
#ExtRunE

#Ext_RunE
READ VALUE
#Ext_RunE

Network: 21

Network: 22
Scales actual value from drive -20000 TO +20000 into a -100% to 100%
L
ITD
DTR
L
/R
T

#READ_ACT_VALUE_HIW_PZD2

#READ_ACT_VALUE_HIW_PZD2 -- READ VALUE

2.000000e+002
#Actual_Value_0_100_Perct

#Actual_Value_0_100_Perct -- Out --100 Percent to 100 Percent

Network: 23
Move Actual value PZD 2 from drive -20000 to 20000

EN
#READ_ACT_
VALUE_HIW_
PZD2
READ VALUE
#READ_ACT_
VALUE_HIW_
PZD2 IN

MOVE
ENO
#Main_Actu
al_Value
Out -Main
Actual
Value-20000 to
20000
#Main_
Actual_
OUT Value

Network: 24
PZD 3 out to Data Block

EN
#READ_ACT_
VALUE_HIW_
PZD3
READ VALUE
#READ_ACT_
VALUE_HIW_
PZD3 IN

MOVE
ENO
#PZD_3_REA
D
Out- PZD
From Drive
#PZD_3_
OUT READ

Page 8 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

07/14/2015 07:28:11 AM

Network: 25
PZD 4 out to Data Block

EN
#READ_ACT_
VALUE_HIW_
PZD4
READ VALUE
#READ_ACT_
VALUE_HIW_
PZD4 IN

MOVE
ENO
#PZD_4_REA
D
Out- PZD
From Drive
#PZD_4_
OUT READ

Network: 26
PZD 5 out to Data Block

EN
#READ_ACT_
VALUE_HIW_
PZD5
READ VALUE
#READ_ACT_
VALUE_HIW_
PZD5 IN

MOVE
ENO
#PZD_5_REA
D
Out- PZD
From Drive
#PZD_5_
OUT READ

Network: 27
PZD 6 out to Data Block

EN
#READ_ACT_
VALUE_HIW_
PZD6
READ VALUE
#READ_ACT_
VALUE_HIW_
PZD6 IN

MOVE
ENO
#PZD_6_REA
D
Out- PZD
From Drive
#PZD_6_
OUT READ

Network: 28
PZD 7 out to Data Block

EN
#READ_ACT_
VALUE_HIW_
PZD7
#READ_ACT_
VALUE_HIW_
PZD7 IN

MOVE
ENO

#PZD_7_REA
D
#PZD_7_
OUT READ

Page 9 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

07/14/2015 07:28:11 AM

Network: 29
PZD 8 out to Data Block

EN

MOVE
ENO

#READ_ACT_
VALUE_HIW_
PZD8
#READ_ACT_
VALUE_HIW_
PZD8 IN

#PZD_8_REA
D
#PZD_8_
OUT READ

Network: 30
PZD 9 out to Data Block

EN

MOVE
ENO

#READ_ACT_
VALUE_HIW_
PZD9
#READ_ACT_
VALUE_HIW_
PZD9 IN

#PZD_9_REA
D
#PZD_9_
OUT READ

Network: 31
PZD 10
out to Data Block

EN
#READ_ACT_
VALUE_HIW_
PZD10
#READ_ACT_
VALUE_HIW_
PZD10 IN

MOVE
ENO

#PZD_10_RE
AD
#PZD_10_
OUT READ

Network: 32

Page 10 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

Network: 33

07/14/2015 07:28:11 AM

PPO1

CMP ==I
#PPO
PPO 1-5
#PPO IN1

SFC15
Write Consistent
Data to a Standard
DP Slave
"DPWR_DAT"
EN
ENO
#addresste
mp
#addresste
mp LADDR

#Ret_Val_E
rror2
#Ret_Val_
RET_VAL Error2

1 IN2
P#DIX
48.0 BYTE
4 RECORD

Network: 34

PPO3

CMP ==I
#PPO
PPO 1-5
#PPO IN1

SFC15
Write Consistent
Data to a Standard
DP Slave
"DPWR_DAT"
EN
ENO
#addresste
mp
#addresste
mp LADDR

#Ret_Val_E
rror2
#Ret_Val_
RET_VAL Error2

2 IN2
P#DIX
48.0 BYTE
12 RECORD

Network: 35

PPO3

CMP ==I
#PPO
PPO 1-5
#PPO IN1

SFC15
Write Consistent
Data to a Standard
DP Slave
"DPWR_DAT"
EN
ENO
#addresste
mp
#addresste
mp LADDR

#Ret_Val_E
rror2
#Ret_Val_
RET_VAL Error2

3 IN2
P#DIX
48.0 BYTE
4 RECORD

Page 11 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

Network: 36

07/14/2015 07:28:11 AM

PPO4

DP Write Block

SFC15
Write Consistent
Data to a Standard
DP Slave
"DPWR_DAT"
EN
ENO

CMP ==I
#PPO
PPO 1-5
#PPO IN1

#addresste
mp
#addresste
mp LADDR

#Ret_Val_E
rror2
#Ret_Val_
RET_VAL Error2

4 IN2
P#DIX
48.0 BYTE
12 RECORD

Network: 37

PPO5

DP Write Block

SFC15
Write Consistent
Data to a Standard
DP Slave
"DPWR_DAT"
EN
ENO

CMP ==I
#PPO
PPO 1-5
#PPO IN1

#addresste
mp
#addresste
mp LADDR

#Ret_Val_E
rror2
#Ret_Val_
RET_VAL Error2

5 IN2
P#DIX
48.0 BYTE
20 RECORD

Network: 38

Network: 39
Write to Drive ON/OFF Command
#On_Off
ON OFF
Command
Cw bit0
#On_Off

#OFF_1
DRIVE BIT
0
#OFF_1

Page 12 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

07/14/2015 07:28:11 AM

Network: 40
Write to Drive Coast Command
#Off_2_Coa
st
OFF 2
Coast Cw
bit1
#Off_2_
Coast

#OFF_2
DRIVE BIT
1
#OFF_2

Network: 41
Write to Drive Quick Stop Command
#Off_3_Q_S
top
OFF 3
Quick
Stop Cw
bit2
#Off_3_Q_
Stop

#OFF_3
DRIVE BIT
2
#OFF_3

Network: 42
Write to Drive Operation Enable
#Enable_Op
eration
Enable
Drive
Operation
Cw bit3
#Enable_
Operation

#OPERATION
_ENABLE
DRIVE BIT
3
#OPERATION
_ENABLE

Network: 43
Write to Drive Ramp Generator Enable
#Ramp_Gen_
Enable
Ramp
Generator
Enable Cw
bit4
#Ramp_Gen_
Enable

#RAMP_GEN_
ENABLE_1
DRIVE BIT
4
#RAMP_GEN_
ENABLE_1

Page 13 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

07/14/2015 07:28:11 AM

Network: 44
Write to Drive Ramp Generator Hold Command
#Ramp_Gen_
Hold
Ramp
Generator
Hold Cw
bit5
#Ramp_Gen_
Hold

#RAMP_GENE
RATOR_HOLD
DRIVE BIT
5
#RAMP_
GENERATOR_
HOLD

Network: 45
Write to Drive Setpoint Release Command
#Ramp_Gen_
Setpoint
Ramp
Generator
Setpoint
Cw bit6
#Ramp_Gen_
Setpoint

#SETPOINT_
ENABLE_COM
MAND
DRIVE BIT
6
#SETPOINT_
ENABLE_
COMMAND

Network: 46
Write to Drive Fault Reset Command
#Fault_Res
et
Fault
Reset Cw
bit7
#Fault_
Reset

#FAULT_ACK
_COMMAND
DRIVE BIT
7
#FAULT_
ACK_
COMMAND

Network: 47
Write to Drive Jog Command

#Inching1_
Jog
Jog
CommandONLY USED
WITH
ACS800 Cw
bit8
#Inching1_
Jog

#INCHING1
DRIVE BIT
8
-ATTENTION
-THE
CONTROL
WORD HAS
BEEN
EXCHANGED
TO LINE
UP WITH
#INCHING1

Page 14 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

07/14/2015 07:28:11 AM

Network: 48

#Inching2_
1
Remote
CommsMust be
ON Cw bit9
#Inching2_
1

#INCHING2
DRIVE BIT
9 -BITS
IN THE
DRIVE
#INCHING2

Network: 49
Write to Drive Remote Command
#Remote_Co
ms
CtrWord
bit10
#Remote_
Coms

#REMOTE_CO
MMAND
DRIVE BIT
10
#REMOTE_
COMMAND

Network: 50
Write to Drive Remote Command
#Ext
CtrWord
bit11
#Ext

#Ext_1
DRIVE BIT
11
#Ext_1

Network: 51
Write to Drive Speed Reference Command

EN
#Speed_Ref
erence
Speed
Reference-20000
to 20000
#Speed_
Reference IN

MOVE
ENO
#SPEED_COM
MAND_PZD2
WRITE
VALUE
#SPEED_
COMMAND_
OUT PZD2

Page 15 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

07/14/2015 07:28:11 AM

Network: 52
Write to Drive

EN
#PZD_3_WRI
TE
PZD Write
#PZD_3_
WRITE IN

MOVE
ENO
#ACT_VALUE
_WRITE_PZD
3
WRITE
VALUE
#ACT_
VALUE_
OUT WRITE_PZD3

Network: 53
Write to Drive

EN
#PZD_4_WRI
TE
PZD Write
#PZD_4_
WRITE IN

MOVE
ENO
#ACT_VALUE
_WRITE_PZD
4
WRITE
VALUE
#ACT_
VALUE_
OUT WRITE_PZD4

Network: 54
Write to Drive

EN
#PZD_5_WRI
TE
PZD Write
#PZD_5_
WRITE IN

MOVE
ENO
#ACT_VALUE
_WRITE_PZD
5
WRITE
VALUE
#ACT_
VALUE_
OUT WRITE_PZD5

Network: 55
Write to Drive

EN
#PZD_6_WRI
TE
PZD Write
#PZD_6_
WRITE IN

MOVE
ENO
#ACT_VALUE
_WRITE_PZD
6
WRITE
VALUE
#ACT_
VALUE_
OUT WRITE_PZD6

Page 16 of 17

SIMATIC

ACS_S7\
SIMATIC 300(1)\CPU 315-2 DP\...\FB12 - <offline>

07/14/2015 07:28:11 AM

Network: 56
Write to Drive

EN
#PZD_7_WRI
TE
#PZD_7_
WRITE IN

MOVE
ENO
#ACT_VALUE
_WRITE_PZD
7
#ACT_
VALUE_
OUT WRITE_PZD7

Network: 57
Write to Drive

EN
#PZD_8_WRI
TE
#PZD_8_
WRITE IN

MOVE
ENO
#ACT_VALUE
_WRITE_PZD
8
#ACT_
VALUE_
OUT WRITE_PZD8

Network: 58
Write to Drive

EN
#PZD_9_WRI
TE
#PZD_9_
WRITE IN

MOVE
ENO
#ACT_VALUE
_WRITE_PZD
9
#ACT_
VALUE_
OUT WRITE_PZD9

Network: 59
Write to Drive

EN
#PZD_10_WR
ITE
#PZD_10_
WRITE IN

MOVE
ENO
#ACT_VALUE
_WRITE_PZD
10
#ACT_
VALUE_
WRITE_
OUT PZD10

Page 17 of 17