Sie sind auf Seite 1von 28

Security Level:

1+1 HSB-FD-SD
Commissioning

www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

CONTENT

Basic Knowledge
1+1 HSB
1+1 FD
1+1 SD

Basic Knowledge

1+1 Configuration
For RTN 620, the paired slots (slot5 and slot7) consist a 1+1 protection group; the

paired slots (slot6 and slot8) consist another 1+1 protection group.
Slot 5 and slot 6 is main slot respectively.
For 1+1 HSB and SD application, It is only necessary to configure main IF board

parameters.
For 1+1 FD application, It is necessary to configure main parameters and standby

parameters respectively.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 3

Basic Knowledge

Trigger Conditions of the automatic HSB switching


Switching Conditions

Description

The hardware of the IF board is faulty.


The hardware of the ODU is faulty.
POWER_FAIL
VOLT_LOS IF Board
RADIO_TSL_HIGH
RADIO_TSL_LOW
RADIO_RSL_HIGH

At the same priority.

IF_INPWR_ABN
CONFIG_NOSUPPORT
R_LOC
R_LOF
R_LOS
MW_LOF
The IF connection cable is faulty.
HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 4

Basic Knowledge

Trigger Conditions of the automatic HSM switching


Switching Conditions

Description

R_LOC
R_LOF

High

R_LOS
MW_LOF

Medium

MW_FECUNCOR
B1_SD (IDU 620 PDH)

Low

B2_SD (IDU 620 SDH )


MW_BER_SD IDU 605 2B/2F

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 5

Basic Knowledge

Hybrid Coupler with Waveguide Interface


Coupler Type

Description

Asymmetrical Hybrid
Coupler(6dB)

with one main channel and


one standby channel.

Main ODU port insertion


loss, dB max:1.8 (38G: 2.0);
Standby ODU port insertion
loss, dB max: 7.2 (38G:7.4)

Symmetrical Hybrid
Coupler (3dB)

with equal attenuation in


both channels

ODU port insertion loss, db


max:3.8 (38G:4.0).

HUAWEI TECHNOLOGIES CO., LTD.

Application

Huawei Confidential

Receive Power

Page 6

Basic Knowledge

Trigger Conditions and Antenna Aligning


Alarms R_LOF,R_LOS,MW_LOF are the microwave link alarm.
While aligning antennas, the microwave link is not stable, will create these alarms.
In order to finish antennas aligning quickly, for 1+1 application, we suggest turn off

the standby IF ODU-PWR switch at first, after antenna aligning finishing, turn on
the standby IF ODU-PWR.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 7

Basic Knowledge

1+1 HSB/FD/SD Compare


Item

HSB

FD

SD

Notes

Quantity of ODU

HSB/SD: main ODU type is


same as standby.

Quantity of Antenna

1/2

Quantity of Hybrid Coupler

1/0

Quantity of Frequency Channel

HSB/SD: Only configure main


IF parameters.
FD: Configure main and
standby IF parameters
respectively.

HSB Support

HSM Support

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 8

CONTENT

Basic Knowledge
1+1 HSB
1+1 FD
1+1 SD

1+1 HSB Commissioning

1+1 HSB Commissioning Steps


Link 1+1
Configure

Parameters
Configure

Turn off Standby


IF ODU-PWR
Switch

Turn on Standby
IF ODU-PWR
Switch

1+1 Switch State


and Test

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Align Antenna

Page 10

1+1 HSB Commissioning

Link 1+1 Configure

To Next Page

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 11

1+1 HSB Commissioning

Link 1+1 Configure

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 12

1+1 HSB Commissioning

For 1+1 HSB, only configure main IF board


parameters.

IP Parameters Configure

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 13

1+1 HSB Commissioning

Query 1+1 HSB Switch State

Switch State

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 14

1+1 HSB Commissioning


1+1 Switch Control

Right Click

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 15

CONTENT

Basic Knowledge
1+1 HSB
1+1 FD
1+1 SD

1+1 FD Commissioning

1+1 FD Commissioning Steps


Link 1+1
Configure

Parameters
Configure

Turn off Standby


IF ODU-PWR
Switch

Turn on Standby
IF ODU-PWR
Switch

1+1 Switch State


and Test

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Align Antenna

Page 17

1+1 FD Commissioning

Link 1+1 Configure

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 18

1+1 FD Commissioning

IF Parameters Configure

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 19

1+1 FD Commissioning

IF Parameters Configure

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 20

CONTENT

Basic Knowledge
1+1 HSB
1+1 FD
1+1 SD

1+1 SD Commissioning

1+1 SD Commissioning Steps


Link 1+1
Configure

IF Parameters
Configure

Turn off Standby


IF ODU-PWR
Switch

Turn on Standby
IF ODU-PWR
Switch

Align Standby
Antenna

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Align main
Antenna

Page 22

1+1 SD Commissioning

1+1 Link Configure

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 23

1+1 SD Commissioning

For 1+1 SD, only configure main IF board


parameters.

Parameters Configure

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 24

1+1 SD Commissioning
Turn off two side standby ODU's power, turn on two main ODU's power, firstly, align

two main antennas.

: ODU Power on.


X: ODU Power off.
HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 25

1+1 SD Commissioning
Turn on local site standby ODU's power, keep opposite site main antenna fixed,

align local standby antenna towards opposite main one.

: ODU Power on.


X: ODU Power off.
HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 26

1+1 SD Commissioning
Turn on opposite standby ODU's power, keep local main antenna fixed, align

opposite standby antenna towards local main one.

: ODU Power on.


X: ODU Power off.
HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 27

Thank you
www.huawei.com