Sie sind auf Seite 1von 1

Uponor East Europe

Uponor return temperature limiter


(Art. Nr.: 1013005)

The most common application of the return temperature limiter is in the low-temperature range,
with combined underfloor-element/radiator heating systems, for the temperature control of smaller
underfloor heating systems covering an area of up to 15 m2. The return temperature limiter is also
suitable for use in combined wall/radiator heating systems.

The return temperature limiter regulates the return temperature of the underfloor heating system,
functioning in a similar way to a thermostat valve to control room temperature. The return
temperature limiter allows the target temperature (e.g. the return temperature for the underfloor
heating system) to be limited within a range of 25 °C to 65 °C. The target temperature setting is
factory adjusted to a maximum of 50 °C.

The return temperature limiter functions automatically and without a power supply. Its function is
based on the transfer of heat from the flowing medium to a specially designed thermostatic sensor.
The setting corresponds to the return temperature in the underfloor heating system. If the return
temperature in the underfloor heating system exceeds the preset target temperature setting, the
valve shuts. The valve does not reopen until the return temperature has once more dropped to
below the preset target value.

Note that the default supply temperature of the heating system must be suitable for the Underfloor
system being used, and that a maximum temperature limiter should be fitted. The supply
temperature for an underfloor heating system is limited, according to EN 1264, to a maximum of
55 °C. The indications of the screed and/or wall plaster supplier should also be taken into account.

The use of the return temperature limiter as a room thermostat for a radiant heating system does
not conform to paragraph 12 of the EnEV, which establishes standards for the use of automatic
devices for room-temperature control.

Return temperature limiter

For regulating the return temperature of smaller


Underfloor heating systems (up to 15 m2).
Consisting of cover panel (white), fast-action
ventilator and thermostat for return temperature
limiting between 25 °C and 65 °C. The return
temperature limit is factory-adjusted to approx.
50 °C.

Permitted operating pressure: max. 10 bar


kv-value: 0,45
Connections: 3⁄4 Euro-cone
Dimensions (H x W x D): 150 x 122 x 65 mm
Item No.: 1013005