DESIGN FOR BASE PLATE

From Tower Crane Operation manual, the following


are the maximum resulting forces at the column base
Total (Dead + Wind)

Vertical
Horizontal

=
=

250 Kn
1735 Kn

Permissible Stress in M30 Concrete in Direct compression 0.6fcu


=
Permissible bending stress in base plate (Grade 43)
=
Recommended Load for an HSFG_(8.8 Grade)
(For M36 Bolt)
Tensile
=
Shear
=

18 N/mm
275 N/mm
366 Kn
306 Kn

Area of base Plate Required to transmit the Loads to Concrete.


Areq
=
250 * 1000 /18
=
13888.89 mm
Providing, 300x500mm Size base plate
Bearing pressure on Concrete

=
=
<

Providing 4nos M36-HSFG bolts, There is no Uplift in beams


Maximum Shear force per Bolt
=
=
<
Hence Ok, Safe

18 * 1000 / (500*500)
1.67 N/mm
18.00 N/mm

1735/6
289.2 Kn
306.0 Kn

(Down)
(Left)