Sie sind auf Seite 1von 3

Pipe No

Covering
Outside Diameter, in.
Emissivity
Barometric Pressure [psia]
Steam Pressure [psig]
Steam Temperature
Average Steam Temp
Room Temperature

Average Room Temp


Time/run [min]

Length of Pipe = 10 ft
2

1
Bare Pipe

Paint
1.315
0.88
14.696
30
84
87
91
87.3
35
33.0
33.0
33.7
15

Silver Chrome Pai


1.315
0.96
14.696
30
75
79
90
81.3
35
33.0
33.0
33.7
15

2.875
0.26
14.696
30
79
89
91
86.3
35
33.0
33.0
33.7
15

0 ft
4
85% Magnesia
Insulation
3.1875
0.16
14.696
30
83
91
92
88.7
35
33.0
33.0
33.7
15

Pipe No.

Trial

Surface Temperature

A
108
116
99
61
B
107
114
94
61
1st
C
112
112
103
62
D
110
113
104
66
Average
109.25
113.75
100
62.5
A
115
117
112
57
B
115
116
108
62
2nd
C
119
110
115
62
D
117
110
103
64
Average
116.5
113.25
109.5
61.25
A
119
117
104
59
B
112
114
108
60
3rd
C
113
116
104
60
D
113
113
112
60
Average
114.25
115
107
59.75
Average Surface Temp [C]
113.33
114
105.5
61.17
[F]
236.00
237.20
221.90
142.10
Volume of Condensate (mL)
910
930
940
1070
Outside Diameter, in.
1.315
1.315
2.875
3.1875
ft
0.110
0.110
0.240
0.266
Room Temperature
33.7
92.66
Emissivity
0.88
0.96
0.26
0.16
LE
0 -2.197802 -3.296703 -17.58242
hc [ Btu/hr.ft^2.F] 2.525835 2.531105 2.024111 1.551321
hr [ Btu/hr.ft^2.F] 0.032164 0.035527 0.008182 0.00187

Das könnte Ihnen auch gefallen