Sie sind auf Seite 1von 39
The DeltaV digital automation system helps you improve your operations by harnessing today’s predictive technologies in an easy, intuitive, and interoperable way to connect your people, processes, and production. 1/0 on Demand What you want, when you want it, where you want it. With the introduction of /0 on Demand, an unprecedented amount of field /0 adaptability, ease-oF integration and plant availability becomes possible. Costs and concems around single points of failure, marshalled cross- \witingy power and grounding of Founoanion” fieldbus segments, and late project O and process Regardless of 0 type— traditionally wired IO, Fousnarion fieldbus, Profibus DP, DeviceNet, AS-i bus, or even redundant ‘wireless—you can add and begin Using the information all natively and with far less engineering, design, and field work. You choose the I/O you need, we make it easy. VO on Demand-your /0, any design change orders can completely disappear. type, anytime, anywhere rc REED ilis gs Process control facilites and applications certainly come in all sizes and levels of complexity. To maximize the return on your investment, the automation system should easily scale without adding complexity. Partof Emerson's PlantWeb™ architecture, the Delta™ system is built from the ground up for ultimate scalability. Regardless of your application's size, the Delta Page 2—Deltav System Overview Ultimate Scalability Inherent functionality regardless of size. system keeps the same look and feel. This reduces administration and training costs, and optimizes both initial investment and future expansions. From bench top, to pilot plant, to full production; from 25 1/0 points to over 1 million, yoursystem adapts to meet your needs. Sane ‘operations experience, Same maintenance experience. Same system, scaled to fit. Easy. Seed esis ere Plant availabilty at peak per- formance, that’s really the ultimate goal of any automaton system, Keeping the facility running in a safe and secure manner, while ‘optimizing the production is what the DeltaV system with AMS™ ‘Suite: Inteligent Device Manager isallabout. sta Deol rice Allthe predictive power of smart devicesis combined with the latest advanced control technologies to provide the ultimate in embedded intelligent control. Whether it’s the latest in predictive device alerts, adaptive tuning, or model predictive control-you have the Embedded Intelligent Control Advanced technologies that are easy to use and maintain. power of embedded intelligent control within an integrated system that’s easy to use and maintain, Vv Deurav AMS Inherently Integrated Delivering the power of PlantWeb to every installation. The DeltaV syste ias the. The inherent integration of the _the DeltaV system. And, itis tightly commissioning and monitoring _DeltaVsystemextendsto batch, _ integrated with: power of AMS Device Manager advanced control, change mSyncade™ suite which provides included. This combination management, engineering tools, _operationsmanagement Blan connectsyour operationswith the diagnostics, simulation, and event ml AMS™ Suite which provides predictive intelligenceinsmart and continuous historian. predictive maintenance 7 devices and creates PlantWeb—for mDeltaV Sis™system which ‘greater availability. Emerson provides solutions that provides integrated yet integrate with your plant systems separate safety above, below, and in parallel with prey Bente ecu ec Over the last ten years, commercial off the-shelf technologies (COTS) have provided tremendous inereases in functionality and cost advantages to end-users of today's automation systems. The DeltaV system was the first such system on the market, and continues to provide open, proven products to its process manufacturers. integrated machinery monitoring. Built for Purpose Designed specifically for your process control applications. However, while COTS has given many advantages, it has also come with expensive administration and life-cycle costs requirements. Abetter approach is to take advantage of the cost benefits and open standards of COTS, but to add functionality that allows the equipment to function much more like other parts of the system—plug-and-play full lifecycle support without upgrades, builtin security ete. We call this balance “Built for Purpose", and the DeltaV systems the first automation system to address this critical need in many of the most important facets of the system. Page 3-Deltav System Overview Piety Scalability The DeltaV Architecture Improve plant performance with PlantWeb =*> The proven PlantWeb digital plant a Application -———=J ad architecture helps you detect ‘Station | ‘operations, process, and equipment ——— problems before they even occur, Maintenance soyou can move from reactive to proactive and profitable plant operations. Page 4Deltav System Overview Engineering Frese Operations The DeltaV architecture provides reliability through redundancy: MEthemet network connections Controllers Controller & feld interface powersupplies Digital HART 1/0 and classic field interface cards HH Founosnos fieldbus with integrated powerand diagnostics Profibus DP Master interface Modbus RTU/ASCI interface SIS logic solvers SISNet communications mBatch Executive Zone servers OPC servers Digital Communications 1m Founnarion fieldbus HART sm WirelessHART Profibus DP mDeviceNet mAS-ibus m Modbus RTU/ASCIYTCP mEthernet/IP morc OPC Express interface (Xi) SBEgo Page 5—DeltaV System Overview Electronic Marshalling The I/O you want, when you want it, where you want it. ‘The DeltaV system's unique regardless of signal type or control flexible field architecture delivers strategy. JO on demand—providing the [0 youwant, when youwantit, where With Electronic Marshalling, each youwantit.[tisflexible because terminal lock hasa channel youcannow decouple the process characterization module, or design from the 0 infrastructure CHARM, which includes an A/D design, to easily incorporate late converter and associated signal process changes into the characterization for different types ‘automation system, ‘analog and digital (0. Field wiring ‘of any signal type can be termin- Electronic Marshalling ated anywhere and characterized Tight project schedules with by the various CHARMS. A digital ‘changing requirements during communication bus runs along the design and implementation are a__ terminal strip to send device signal ‘way oflife. DeltaV Electronic information to the top of the Marshalling lets you land field redundant CHARM I/O card where ‘cabling wherever you want, JO conditioning is completed. Marshalling Cabinet Page 6Deltav System Overview Integrated CHARMS IECHARM base plate snaps on rail IECHARM terminal block snaps into base Auto keying sets terminal block ‘when frst CHARM is inserted CHARM secured with locking mechanism in both operating and “knife-edge” disconnect positions Winsertable/removable under power in a Zone 2 environment ‘Signal fault protection and