Beruflich Dokumente
Kultur Dokumente
Mating Ring
Primary Ring
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
1.
2.
3.
4.
5.
1.
2.
3.
4.
1. Spring failure.
2. Erosion damage of hardware.
3. Corrosion of drive.
1. Replace parts.
2. Check seal manufacturer for other material.
SYMPTOMS
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
Carbon dust
accumulating on outside
of gland plate.
Seal leaks.
1. Abrasive fluid.
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
1.
2.
3.
4.
5.
Mating Ring
Primary Ring
contact pattern
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
no contact
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
4. Mechanical Distortion
OBSERVATION:
Two large contact spots on mating ring pattern fades away between contact areas. 360 contact on primary ring.
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
1. Mechanical distortion.
2. Faces not flat.
high spots
no contact
Possible erosion of the primary ring (wire
drawing) if allowed to remain stationary.
5. Mechanical Distortion
OBSERVATION:
Uneven circumferential contact spots on mating ring, pattern fades away between contact areas. 360 contact on primary ring.
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
1. Mechanical distortion.
2. Faces not flat.
no contact
contact pattern
Possible erosion of the primary ring (wire drawing)
if allowed to remain stationary under pressure.
6. Mechanical Distortion
OBSERVATION:
Mating ring shows intermittent contacting and non-contacting areas. High spots are at each bolt location. 360 contact on primary ring.
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
no contact
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
1. Check seal chamber pressure for adequate vapor
pressure margin.
2. Check seal setting for proper working height.
3. Check for proper running clearances between shaft
and primary ring at operating temperature.
4. Review flush system design; increase flush flow rate.
5. Review details of seal selection.
6. Use distributed flush design instead of single
point flush.
distressed or heat
checked area
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
depth of
groove
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
highly polished
area possible
opposite drive pin
hole (only if pin
has been used)
slightly wider
contact area on
mating ring
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE PROCEDURES
For your nearest John Crane facility, please contact one of the locations below.
North America
Global Headquarters
Morton Grove, IL, USA
1-800-SEALING
Tel: 1-847-967-2400
Fax: 1-847-967-3915
Europe
Slough, UK
Latin America
So Paulo, Brazil
Asia Pacific
Singapore
Tel: 44-1753-224000
Fax: 44-1753-224224
Tel: 55-11-3371-2500
Fax: 55-11-3371-2599
Tel: 971-481-27800
Fax: 971-488-62830
Tel: 65-6518-1800
Fax: 65-6518-1803
If the products featured will be used in a potentially dangerous and/or hazardous process, your John Crane representative should be consulted prior to
their selection and use. In the interest of continuous development, John Crane Companies reserve the right to alter designs and specifications without
prior notice. It is dangerous to smoke while handling products made from PTFE. Old and new PTFE products must not be incinerated. ISO 9001 and ISO
14001 Certified, details available on request.
2011 John Crane
www.johncrane.com
www.johncranetoday.com
B-SealLeakTB