Sie sind auf Seite 1von 2

Cek status SNMP

cek datarate
cek name, addinfo, netmodel
cek admin dan oper status
Lihat info system
Lihat info IP, mac dslam
Cek system clock
get system

:
:
:
:
:
:
:
:

get
get
get
get
get
get
get
Cek

cmoperator [public]
cmadslmodem [1.7.15]
cmif [1.7.15]
ift [1.7.15]
cmsystem
cmif [1.2.1]
cmsystem calendar
uptime, dll

Create snmp public


nmp priviledge=view
Set Admin Port
Set netmodel, encaps
destpii=1.2.1.0
Set label port
sl"
set name berdasarkan no reg
set datarate adsl
rxrate=384000
set datarate sdsl
Set IP DSLAM
Buat akses
=create
Hapus akses
Set system clock
Simpan
restart

: set cmoperator [public] state=create context=s


: set ift [1.7.15] adminstatus=up/down
: set cmif [1.6.14] netmodel=vwan encaps=rfc1483
: set cmif [1.7.15] additionalinfo="BudiAsih16-d
: set cmif [1.7.15] name="_422292876"
: set cmadslmodem [1.7.15] maxtxrate=1024000 max
: set cmhd [1.8.9] datarate=1040
: set cmif [1.2.1] ipaddr=202.138.241.125
: set cmoper [username] password = haepoov state
:
:
:
:

set cmoper [username] state=destroy


set cmsystem calend=2014/07/11-10:14:36
set cmsystem command=save
scmrestart

To override the password:


Connect to the DIAG port at 9600-8-N-1
cd "SYSTEM"
rename "config.txt","config.old"
reboot
This will set the CE150/200 to factory defaults.
Default admin username/password for a CE200 is ce200/ce200
Default admin username/password for a CE150 is admin/admin
The commands below will allow setting up a basic config from the command line to
enable further configuration by using: 192.168.1.100 and public/private communi
ties. Rename as needed.
CE200 Setup
----------set cmIfaceTable [1.2.1.0] Name="" GroupName="" AdditionalInfo="" NetModel=IP Ip
Addr=192.168.1.100 NetMask=255.255.255.0 FarEndAddr=0.0.0.0 DestPII=0.0.0.0 CMC
PCompatible=No EncapsulationType=None ServiceClass=None
set cmOperatorTable ["ce200"] Password="whateveryouwilluse" State=Active Contex
t=NonSNMP Privilege=Security
set cmOperatorTable ["public"] State=Active Context=SNMP Privilege=View
set cmOperatorTable ["private"] State=Active Context=SNMP Privilege=Provision

CE150 Setup
-----------set cmIfaceTable [1.3.1.0] Name="" GroupName="" AdditionalInfo="" NetModel=IP Ip
Addr=192.168.1.100 NetMask=255.255.255.0 FarEndAddr=0.0.0.0 DestPII=0.0.0.0 CMC
PCompatible=No EncapsulationType=None ServiceClass=None
set cmOperatorTable ["admin"] Password="whateveryouwilluse" State=Active Contex
t=NonSNMP Privilege=Security
set cmOperatorTable ["public"] Password="whateveryouwilluse" State=Active Conte
xt=SNMP Privilege=View
set cmOperatorTable ["private"] State=Active Context=SNMP Privilege=Provision
Routing
------set iproute [0.0.0.0] type=invalid (remove default route)
set ipRouteTable [0.0.0.0] NextHop=192.168.1.1 Mask=0.0.0.0
Backup
------CRAFT> set cmmaintcmd [configbackup]
CRAFT> set cmmaintcmd [configbackup]
primaryipaddr=206.71.190.4
CRAFT> set cmmaintcmd [configbackup]
secondaryipaddr=206.71.190.5
CRAFT> set cmmaintcmd [configbackup]
ce200config/sys1
CRAFT> set cmmaintcmd [configbackup]
CRAFT> set cmmaintcmd [configbackup]
pass=
CRAFT> set cmmaintcmd [configbackup]
CRAFT> set cmmaintcmd [configbackup]
CRAFT> set cmmaintcmd [configbackup]

rowstatus=createandwait

directory= /
basefilename=sysdeltabu
username=anonymous

Restore
----------CRAFT> set cmmaintcmd [configrestore]
notinservice
CRAFT> set cmmaintcmd [configrestore]
206.71.190.4
CRAFT> set cmmaintcmd [configrestore]
/ce200config/sys1
CRAFT> set cmmaintcmd [configrestore]
config206_71_190_419991101_0000
CRAFT> set cmmaintcmd [configrestore]
password=
CRAFT> set cmmaintcmd [configrestore]

recurrence=168
start=99/04/01-03:20
rowstatus=active

Restart
------set cmsystem command=restart

rowstatus=
primaryipaddr=
directory=
basefilename=
username= anonymous
rowstatus= active

Das könnte Ihnen auch gefallen