DATOS DEL PROBLEMA

NOMBRE:

IZQUIERDO VARGAS ROSARIO

PLANTA TIPICA: PLANTA B


USO:
HOTEL
UBICACIN:
LAMBAYEQUE
TIPO DE SUELO : SUELO FLEXILE
ESPECIFICACIONES:
f'c =
210 kg/cm2
fy =
4200 kg/cm2

PLANTA DE LA EDIFICACION:

SE PIDE:

a) Predimensionamiento de Vigas

VIGA 1

=/1
0

0.6 m

0.3 m

=/
2
VIGA 2

=/1
0

0.5 m

=/
2

0.25 m

b) Predimensionamiento de Losa Macisa

_=/25
Aligerado

Maciza

e=

0.2

_=_(
5_ )

0.15 m

c) Predimensionamiento de Columnas
=/(0.45 ^
Columnas centradas )
Columnas esquinada =/(0.35 ^
)
Columna excentrica

=/(0.35 ^
)

Categoria C = Pservicio = 1000 kgf/m2


Area tributaria (tipo 1)
Area tributaria (tipo 2)
Area tributaria (tipo 3)

30 m2
15 m2
7.5 m2

area (cm2) y lado (cm)

piso
piso
piso
piso
piso

5
4
3
2
1

TIPO1
Area
317.46
634.921
952.381
1269.84
1587.3

Lado
17.817
25.198
30.861
35.635
39.841

TIPO2
Area
204.08
408.16
612.24
816.33
1020

Lado
14.2857
20.2031
24.7436
28.5714
31.9438

TIPO3
Area
102
204.08
306.12
408.16
510.2

Lado
10.102
14.286
17.496
20.203
22.588

Considerando que el area debe ser mayor a 1000 cm2

piso
piso
piso
piso
piso

5
4
3
2
1

TIPO1
Area
1000
1000
1000
1269.84
1587.3

Lado
32
32
32
36
40

TIPO2
Area
1000
1000
1000
1000
1020

Lado
32
32
32
32
32

TIPO3
Area
1000
1000
1000
1000
1000

Lado
32
32
32
32
32

COMPROBACION DE ROTURA
donde Lado de columna = (70 - 80%)h
Lcolumna = 0.7 x (60cm) = 42 cm
Entonces todas las columnas deben tener 42 cm. Lado.
METODO DE CONTROL
Inercia viga 1
Inercia viga 2

540000.00
260416.67

Inercia Columna (42cm x 42cm)

cm4
cm4
259308

REFORMULACION:
1er piso H=4.3 m.
C.Centrada a=H/8
C.Excentrica a=H/9
C.Esquinada a=H/10

0.5375 cm
0.4778 cm
43 cm

Analisis 1er piso


Inercia C.Cen.
Inercia C.Exce.
Inercia C.Esq.

2do al 5to piso H=3.3 m.


C.Centrada a=H/8
C.Excentrica a=H/9
C.Esquinada a=H/10

Analisis 2do al 5to piso


540000
442368
284900

Inercia C.Cen.
Inercia C.Exce.
Inercia C.Esq.

Por lo que la dimension elegida es de 30x60 cm. para todas las columnas, cumpliendo

d) Predimensionamiento de las zapatas


>/
(.)
Como el suelo de la edificacion es Rigido entonces:
qadm(kg/cm2) =
K=

4
0.9

Area y lado de Zapata (cm2)


CENTRADA
ESQUINADA
EXCENTRICA
Area
Lado Area
Lado
Area
Lado
41667
205
20833 145 10416.7 103

ELEVACION DEL A EDIFICACION:

2.8
5
2.8
5
2.8
5
2.8

=/2
5

10.582

to piso H=3.3 m.
ada a=H/8
0.4125 cm
trica a=H/9
0.3667 cm
nada a=H/10
0.33 cm

2do al 5to piso


235480
156180
98827

as columnas, cumpliendo el metodo de control de rotula plastica

h5

h4
h3

h2

h1

2
1.0

5.8

8.6

11.4

14.2

METRADO DE CARGAS POR SISMO


PISO 5
CARGA VIVA
Losa maciza
Vigas tipo 1
Vigas tipo 2
Columnas

18.50 x 15.50 x 0.15 x 2.4 =


12 x 0.4 x 0.45 x 5.5 x 2.4 =
12 x 0.30 x 0.35 x 4.5 x 2.4 =
16 x 0.50 x 3.15 x 0.50 x 2.4 =

PESO TOTAL

182.76

103.23
28.512
13.608
30.24
175.59

Ton

Toneladas

PISO 4,3 y 2
CARGA VIVA
Losa maciza
Vigas tipo 1
Vigas tipo 2
Columnas

18.50 x 15.50 x 0.15 x 2.4 =


12 x 0.4 x 0.45 x 5.5 x 2.4 =
12 x 0.3 x 0.35 x 4.5 x 2.4 =
16 x 0.50x 3.15 x 0.5 x 2.4 =

PESO TOTAL

189.93

103.23
28.512
13.608
30.24
175.59

Ton

Ton

PISO 1
CARGA VIVA
Losa maciza
Vigas tipo 1
Vigas tipo 2
Columnas

18.50 x 15.50 x 0.15 x 2.4 =


12 x 0.4 x 0.45 x 5.5 x 2.4 =
12 x 0.3 x 0.35 x 4.5 x 2.4 =
16 x 0.50 x 4.15 x 0.50 x 2.4 =

PESO TOTAL

199.53

103.23
28.512
13.608
39.84
185.19

Ton

Ton

Peso total de la
estructura =

952.07

Ton

RESUMEN
P5
P4
P3
P2
P1

=
=
=
=
=

182.76
189.93
189.93
189.93
199.53

Ton
Ton
Ton
Ton
Ton

CARGA VIVA
s/c techo

0.25 x 0.10 x 18.50 x 15.50 =

7.17

Ton

0.25 x 0.20 x 18.50 x 15.50 =

14.34

Ton

0.25 x 0.20 x 18.5 x 15.5 =

14.34

Ton

CARGA VIVA
s/c piso tipico

CARGA VIVA
s/c piso tipico

ANALISIS SISMICO ESTATICO


1

=_/_

PERIODO FUNDAMENTAL

Donde:
T:
hn :

Periodo Fundamental
Altura edificio desde nivel 0 (cero)

DATOS:
hn =
TIPO :
Ct:
2

14.2

m.
APORTICADO

35

=2,5(_/)2,5

FACTOR DE AMPLIFICACION SISMICA

Donde:
C:
Tp :

Factor de amplificacion sismica


Periodo de vibracion del suelo

Evitar resonancia :

Datos:
TIPO DE SUELO :
SUELO RIGIDO
Tp =
0.4
T=
0.4057142857
Verificamos resonancia:

2,5 , =2,5
<2,5 ,
Entonces,

C=
3

2.464789

FUERZA CORTANTE EN LA BASE

=/.

Donde:
V:
C:
Z:
U:
S:
R:
P:

Fuerza cortante en la base


Factor de amplificacion sismica
Zona sismica (Ubicacin del proyecto)
Uso de la edificacion
Factor del suelo
Factor de reduccion sismica
Peso sismico del edificio

Zona sismica: (Z)


ZONA 3
ZONA 2
ZONA 1

Z=
Z=
Z=

0.4
0.3
0.15

ESENCIAL
IMPORTANTE
COMUN

U=
U=
U=

1.5
1.3
1.0

RIGIDO
INTERMEDIO
FLEXIBLE

S=
S=
S=

1.0
1.2
1.4

Factor de reduccion sismica: ( R)


APORTICADO
DUAL

R=
R=

8
7

R=
R=
R=

6
4
6

Uso o importancia: (U)

Factor del Suelo: (S)

MUROS ESTR.
MDL
ALBAILERIA

FUERZA SISMICA POR LA ALTURA


4.1

Si ,

T 0,7 segundos,

Entonces, la Fuerza Sismica (Fi) es:

_=(_ _)/(
_ _ ).

4.1

Si ,

T > 0,7 segundos,

Existe una Fuerza Adicional (Fa) que es:

_=0,07

Entonces la Fuerza Sismica (Fi) es:

_=(_ _)/(
_ _ ).
(_)

CONTROL DE DESPLAZAMIENTOS LATERAL


F5

F4

F3

SISMO EN X

F2

F1

VERIFICANDO:

5 - 4
H5

0.002

<

0.007

4 - 3
H4

0.003

<

0.007

3 - 2
H3

0.004

<

0.007

2 - 1
H2

0.006

<

0.007

1
H1

0.008

>

0.007

SISMO EN Y
F5

F4

F3
F2

F1

VERIFICANDO:

5 - 4
H5

0.003

<

0.007

4 - 3
H4

0.005

<

0.007

3 - 2
H3

0.007

<

0.007

2 - 1
H2

0.008

>

0.007

1
H1

0.009

>

0.007

Ct =
Ct =
Ct =

35
45
60

APORTICADO
DUAL
MUROS ESTRUCTURALES O ALBAILERIA

T=

Entonces,

0.4057

_/)2,5

Tp =
Tp =
Tp =

Entonces,

=2,5

0.4
0.6
0.9

seg.
seg.
seg.

C=

2.4647887

SUELO RIGIDO
SUELO INTERMEDIO
SUELO FLEXIBLE

DATOS DEL PROBLEMA:


ZONA :
Z=
USO:
U=
TIPO DE SUELO :
FACTOR DEL SUELO:
S=
TIPO DE EDIFICACION:
FACT. REDUC. SISMICA:
R=

PESO SISMICO DEL EDIFICIO:


P=

V=

ENTONCES,

/0.125

COMPROBAR :

C/R=

0.3081

>

P1 =

199.53

h1 =

P2 =

189.93

h2 =

5.8

P3 =

189.93

h3 =

8.6

P4 =

189.93

h4 =

11.4

P5 =

182.76

h5 =

14.2

_=0,070,15

Fa =

P1 =

199.53

h1 =

P2 =

189.93

h2 =

5.8

P3 =

189.93

h3 =

8.6

P4 =

189.93

h4 =

11.4

P5 =

182.76

h5 =

14.2

3.3

1
2
3
4
5

=
=
=
=
=

3.3
Donde:

3.3

5 - 4
H5

3.3
4 - 3
H4
3.3
3 - 2
H3
2 - 1
H2
1
H1

OK
OK
OK
OK
REFORZAR

3.3

1
2
3
4
5

=
=
=
=
=

3.3
Donde:
3.3

5 - 4

H5
3.3
4 - 3
H4
3.3
3 - 2
H3
2 - 1
H2
1
H1

OK
OK
OK
REFORZAR
REFORZAR

ALBAILERIA

ZONA 2
0.3
COMUN
1
RIGIDO
1
APORTICADO
8

952.07

Ton

88.00

0.125
OK

0.125

F1 =
F2 =
F3 =
F4 =
F5 =

4.448
12.279
18.207
24.135
28.929

NO HAY

OK

F1 =
F2 =
F3 =
F4 =
F5 =

NO HAY

T
T
T
T
T

es
es
es
es
es

menor
menor
menor
menor
menor

TIPO

24.86
43.98
58.28
69.77
76.44

DERIVA:

o
o
o
o
o

igual
igual
igual
igual
igual

DERIVA

CONCR. ARM.

0.007

ACERO

0.010

ALBAILERIA

0.005

MDL

0.005

CONCR. ARM.

a
a
a
a
a

0.7
0.7
0.7
0.7
0.7

seg.
seg.
seg.
seg.
seg.

0.007

0.007

0.007

0.007

0.007

TIPO

29.6727
55.0154
76.7844
93.1904
102.9631

DERIVA:

0.007

DERIVA

CONCR. ARM.

0.007

ACERO

0.010

ALBAILERIA

0.005

MDL

0.005

CONCR. ARM.

0.007

0.007

0.007

0.007

EXCENTRICIDAD ACCIDENTAL
5.1

COLUMNA
VIGA 1
VIGA 2

REGULARES

DIMENESIONES
0.3
0.6
0.25
0.5
0.3

0.6

MASAS A NIVEL DE ENTREPISOS

6m

6m

6m
18.55

PESO DE LA ESTRUCTUR
PISO
P5
P4
P3
P2

952.07 Ton
PESO (Ton)
182.76
189.93
189.93
189.93

Gravedad (m/s2)
9.81
9.81
9.81
9.81

Mt (ton.s2/m)
18.630
19.361
19.361
19.361

P1

9.81

FACTOR DE ESCALA
Z
U
S
g
R
F.E. =

199.53

0.3
1
1
9.81
8
0.367875

PERIODOS DE VIBRACION
RESULTADOS OBTENIDOS CON EL SAP
MODO
PERIODO (s)
FRECUENCIA
1
0.70641
1.4156
2
0.61514
1.62566
3
0.48506
2.06162
4
0.2175
4.59769
5
0.19341
5.17045
6
0.15155
6.59833
7
0.11458
8.72726
8
0.10522
9.50425

20.339

CONTROL DE DESPLAZAMIENTOS LATERAL


F5

F4

F3
F2

F1

VERIFICANDO:
5 - 4
H5

0.001

<

4 - 3
H4

0.002

<

3 - 2
H3

0.003

<

2 - 1
H2

0.003

<

0.004

<

1
H1

F5

F4

F3
F2

F1

VERIFICANDO:
5 - 4
H5

0.001

<

4 - 3
H4

0.002

<

3 - 2
H3

0.003

<

2 - 1
H2

0.004

<

0.004

<

1
H1

10

FUERZAS INTERNAS MAXIMAS


Fuerza
Interna
N max
V max

Comn
(sismo X+)
6.74 T
4.06 T

Comn

(sismo
Y+)
6.8 T
3.46 T

M max

9.57 T.m

9.16 T.m

18.55

5m
5m
5m

Mr (ton.s2/m)
909.610
945.289
945.289
945.289

15.55

15.55

993.070

SISMO EN X

3.3

3.3

3.3
3.3

3.3

0.007

OK

0.007

OK

0.007

OK

0.007

OK

0.007

OK

SISMO EN Y

3.3

3.3

3.3
3.3

3.3

0.007

OK

0.007

OK

0.007

OK

0.007

OK

0.007

OK

_=0,05_
_=0,05_
ex =

0.9275

ey =

0.7775

TIPO

1
2
3
4
5

=
=
=
=
=

12.66
23.27
32.08
38.48
42.20

Donde:

DERIVA:

5 - 4
H5

0.007

4 - 3
H4

0.007

3 - 2
H3

0.007

2 - 1
H2

0.007

1
H1

0.007

DERIVA

CONCR. ARM.

0.007

ACERO

0.010

ALBAILERIA

0.005

MDL

0.005

CONCR. ARM.

TIPO

1
2
3
4
5

=
=
=
=
=

13.2067
25.8082
36.6187
44.638
49.5381

Donde:

DERIVA:

5 - 4
H5

0.007

4 - 3
H4

0.007

3 - 2
H3

0.007

2 - 1
H2

0.007

0.007

1
H1

DERIVA

CONCR. ARM.

0.007

ACERO

0.010

ALBAILERIA

0.005

MDL

0.005

CONCR. ARM.

Th. ESCALADO

T.H. SIN ESCALAR

Z
U
S
g
R

0.3
1
1
9.81
8

F.E. =

0.367875

Fhistoria

0.0000087756

PA ARRIOSTRES
FACTOR DE ESCALA C=3.5
Z
U
S
g
R

0.3
1
1
9.81
8

F.E. =

0.367875

Fhistoria

0.0000122859

Factor = 0.00001

ESCALAR

Nmax
Vmax
Mmax

Analisis Estatico
(sismo X+)
11.97
6.21
13.35

Analisis Estatico
(sismo Y+)
13.9
6.33
14.7

Nmax
Vmax
Mmax

PISO
5
4
3
2
1

DX(mm)
76.4428
69.7737
58.2751
43.9787
24.8605

DY (mm)
102.9631
93.1904
76.7844
55.0154
29.6727

PISO
5
4
3
2
1

DESPLAZAMIENTO EN X
100
80

DESPLAZAMIENTO (mm)

60

ESTATICO

40

TIEMPO-HISTORIA

ANALISI ESPECTRAL

20
0
0

PISOS

Analisis Espectral
(sismo X+)
6.74
3.71
9.57

Analisis Epectral
(sismo Y+)
6.8
3.27
9.16

Nmax
Vmax
Mmax

Analisis
SIN ESCALAR
Tiempo Historia (sismo
X+)
12.58
6.73
17.52

DX(mm)
42.198
38.477
32.077
23.273
12.664

DY (mm)
49.538
44.638
36.618
25.808
13.207

PISO
5
4
3
2
1

DX(mm)
14.67
13.2
10.74
7.56
4.01

DESPLAZAMIENTO
120
100
80

STATICO

NALISI ESPECTRAL

IEMPO-HISTORIA

DESPLAZAMIENTO (mm)

60
40
20
0
0.5

1.5

2.5

3
PISOS

ESCALADO
Analisis Tiempo - Historia
(sismo Y+)
17.33
7.977
24.17

Nmax
Vmax
Mmax

Analisis Tiempo Historia (sismo X+)


11.04
5.909
15.37

DY (mm)
21.26
19.17
15.79
11.33
5.89

PISO
5
4
3
2
1

DX(mm)
12.87
11.58
9.428
6.634
3.51

DESPLAZAMIENTO EN Y

ESTATICO
ANALISIS ESPECTRAL
TIEMPO - HISTORIA

1.5

2.5

3
PISOS

3.5

4.5

5.5

Analisis Tiempo Historia (sismo Y+)


15.2
6.876
21.21
DY (mm)
18.66
16.82
13.85
9.94
5.173

ESTATICO

ANALISIS ESPECTRAL

TIEMPO - HISTORIA

Nmax
Vmax
Mmax

Analisis
Estatico
(sismo X+)
11.97
6.21
13.35

Analisis
Espectral
(sismo X+)
6.74
3.71
9.57

Analisis
escalado
Tiempo Historia
(sismo X+)
11.04
5.909
15.37

Nmax
Vmax
Mmax

Analisis
Estatico
(sismo X+)
13.9
6.33
14.7

Analisis
Espectral
(sismo X+)
6.8
3.27
9.16

Analisis
escalado
Tiempo Historia
(sismo X+)
15.2
6.876
21.21