CERBERUS PYROTRONICS Installation Instructions MODEL ID-60T-135 Thermal Detector These instructions are written in accordance with the installation guidelines of NFPA No. 72, STANDARD FOR AUTOMATIC FIRE DETECTORS. CAUTION Detection Device Storage DO NOT install this detection device until all construction is completed. DO NOT store this detection device where it can be contaminated by dirt, dust, or humidity. DETECTOR PLACEMENT Locate the ID-60T-35 on the ceiling, at least 4 inch- es from the side walls. For an ideal, smooth ceiling condition, place the detectors at a maximum center ‘spacing of 50 feet (2500 square feet), 25 feet from side walls or room partitions. Cerberus Pyrotronics 8 Fernwood Road Florham Park, New Jersey 07932 P/N 315-090288-2 + + + + + + ToNext Base Ss 4+ ~ Detector Base Remote Relay a Model DB-3S Base Model DB-x3AS euigures Zone Wires Wiring Diagram fom Gerberus Relay" soa Pyrotronics Contacts Compatible ‘3A, 120 VAC 2 Controt Sptionat 3A, 30 VDC. ipmen lomote en ‘Alarm es) Indicator Models RLI-1/RLI-2 - + t 4+ > = ES - = = To Next Base Actual job conditions and sound engineering judgment DETECTOR MOUNTING must determine detector spacing. Consider environ- mental factors including ambient temperature fluctua- tion, and the nature of the fire hazard. Room or area configuration and ceiling type (sloped or flat, smooth or beamed) also dictates placement. Should questions arise regarding detector placement, follow the drawings provided and/or approved by Cerberus Pyrotronics or by its authorized distributors. This is extremely important! The detector placements shown on these drawings were chosen after a careful evaluation of the area being protected. Cerberus Pyro- tronics extensive experience in design of the system assures the best detector placement by following these drawings. DETECTOR WIRING Connect the detector as shown in Figure 1 and wire it to the contro! panel by following the Wiring Diagram on the control panel cover or in the system manual. 2 The detector has a separate base which attaches to a standard 4 inch square, 4 inch octagonal, or single gang switchbox. The size and depth of the box is determined by the NEC for the number and size of conductors used. A finishing trim ring (Model RA-ADB) is available for bases using a 4 inch square box. TO MOUNT: Route all wires outward from outlet box. « When viewing the alarm LED is critical, position the LED mark in the base in the necessary direction. (See Figure 2.) « Mount base to outlet box and route wires through the hole in the center of the base. Make connections directly to the base terminals. Refer to Figure 1 for details. ¢ When mounting the detector base and routing wires through the cutouts in the air shield, make sure the a shield is sealed against air leaks. Open the cutouts only as much as required. e Remove factory installed jumper in base between terminals 1a and 1b, Note: To ensure proper installation of the detector head into the base. check that the wires are properly dressed at installation. a. Position all wires flat against the base. b. Take up all slack in the outlet box. c. Route wires away from connector terminals. BASE MOUNTING HOLES Figure 2 LOCATION WITH i DETECTOR Detector Installation ystacteo in BASE INSTALLATION OF DETECTOR HEAD 1. Align notch in detector, cover to raised surface on outer ring of base (See Figure 3). 2. Push detector head into base and rotate clockwise to make electrical connec- tions. The detector auto- matically stops and locks Figure 3 into place. Detector Mounting

Das könnte Ihnen auch gefallen