LOW VOLTAGE CABLES 0.6/1 KV ELECTRICAL GUIDE | | aeve> 10 9001 : 2000 PIVANL CABLES RRBOIID AME RaOnNpaNice US aL INTRODUCTION RIYADH CABLES GROUP OF COMPANIES (RCGC), isa premier manufacture of quality Wires, Conductors and Cables with a wide range of products. Our commitment to quality, professional outlook and dedicated service put us as one of the leading names in the Cables and Allied Manufacturing Industry in the Middle East and do enjoy a prominent slot in the “Top 100 companies in the Kingdom’. RCGC, located in the Second Industrial City - Riyadh with a paid up capital of S.R. 868 Million, backed by a dedicated work force of over 1500 consisting of high calibre multinational professionals and with advanced produetion facilities sprawling over a complex admeasuring 260000 mis all poised for further expansion, RIYADH CABLES GROUP OF COMPANIES with its steady growth, innovative approach and expertise are committed to maintain and enhance its reputation in the years ahead. We believe that our success to date will provide a springboard for further achievements in the future both in the domestic and export arena alike. RCGC's well defined Quality Assurance System adds to the infrastructure for the most reliable products and ensure its conformity strictly to National/Internaional standards and specific requirements of customers to reach all the corners of Domestic and Export Market. Quality is our prime concern. OUR RANGE OF PRODUCTIO! © Wire and Cable Wiring 450/750 Volts and 500 Volts. © Special Electrical Wires. © Low Voltage Cables 1 kV Copper and Aluminium, PVC and XLPE insulated, armoured, non-armoured and lead sheathed © Medium and High Voltage Cables up to 240 kV Aluminium and Copper, XLPE insulated, armoured, non-armoured and lead sheathed. © Control Cables XLPE and PCV insulated, shielded and non-shielded, armoured, non-armoured and lead sheathed. © Overhead Line Conductors and Aerial Cables:Copper, Aluminium, Aluminium Alloy, Plain, and AW, Steel Wire Reinforced for all voltages up to 500 kV (Bare Conductors). © Telephone Cables. © Copper Rods and PVC Granules for Cable insulation and sheath. Ue APPLICATIONS MAXIMUM CONTINUOUSLY PERMISSIBLE SERVICE VOLTAGE Nominal Maximum Continuously Permissible Service Voltage For Voltage Uo/U 3-Phase systems 4-Phase systems one line with both line conductor conductors; earthed isolated wv. kv kv kv 06/1 12 14 o7 3.5/6 72 83 44 6/10 12 14 i aris 175 20 40 Cables having Uo = U/2 or Uo = U//3 may be used In all a.c. installations with rated voltages up to 1.2 kV, in all single-phase a.c. three -phase installations with rated voltages over 1.2 kV or 1 kV respectively, the neutral point of which is solidly earthed, Inall single-phase a.c. and three-phase installations with rated voltages over 1.2 kV or 1 kV respectively, the neutral point of which is not solidly earthed, ifthe duration of single line-to-earth fault does not exceed 8 hours and the duration of all line-to-earth faults occurring within a year does not exceed 125 hours. If compliance with this condition cannot be ensured the cable life shall be taken into regard anda cable with a higher rated voltage shall be chosen. GUIDELINES FOR LOAD CAPACITY The loading of the cable must be so limited that, at any point of the cable installation, all the heat produced in the conductors under set conditions can be safely dissipated to the ambient medium. Experience has shown that cables may be loaded as indicated in the tables. The values stated in Table no. 1 for cables laid in ground are based on standard service conditions mostly used in power systems of electricity boards. Load Factor 207 Thermal resistivity of soil: 1.0 Km/W (moist area) :2.5KmiW (dryarea) Ground temperature 200 No. ofcables/System — : 1 Laying depth : 0.7 meters CUS as ON The current values apply to cables laid direct in the ground, bedded in sand if necessary and covered with table tiles, the cables route including only a limited number of cables pipes none of them being above 6 meters in length. It is also assumed that any pole mounted distribution points with be shielded as far as possible from direct sunlight. For overhead installations as shown in Table No. 2, continuous load factor 1.0 is permissible. The values given apply to cables laid in air at 30°C. itis assumed here that heat dissipation by convection and radiation will not be impeded, that the ambient temperature will not rise and that there are no external heat sources. These conditions can be taken as metif: © Thecableis laid atleast 2.cm form the nearest wall, floor or ceiling. ® The spacing between adjacent cables is at least twice the cable diameter. © Cables being laid above each other have a vertical separation of at least twice the cable diameter, the cable systems are at least 30 cm. © The rise in ambient temperature due to the dissipating heat is taken into consideration or adequate space and ventilation is provided. © The leading ampacities determined according to IEC publication 287 or CENELEC 64 will be identical. They are based on the following figures for the thermal resistivity of the insulating materials. PVC: 6.0KmiW XLPE : 3.5KmiW We also hold at your disposal computerized calculations for the most varied working conditions and can determine the maximum permissible load currents for almost. any practical service condition. IYADH (SUS sO aC TEI BASED ON DIN 57 298 PART 2 VDE 0298 PART 2 ‘TABLE 1 CURRENT RATING FOR CABLE INSTALLED IN GROUND = 0.6/1 KV BEBE Cable Type NIA)YY ;N(A) YCWY® N(A)2xY a eee oe cen teeae Max. 70° asc got ee arangement | @ | @ e e ee eee ee eee eee a ee eee en eee eee eee ps elas es mes a consent ees eet ees 16 460 | 16 | 98 | 107 | 127 | 408 | toe | ata | tas | azz | ty | ts | 130 eee ee een 185, gar | - | 300 | 414 | aaa | 669 | 420 | aor | soa | zor | 441 | 449 | sze 300 843, i 524 542 632 | 987 | 552 | 564 | eo | 931 | 580 | 587 | 689 500. 1125] - 98 | za | 1174} 715 | 723 | a6 | 1203 | - | 748 | a9 Rao |e 35 192 wg | sar | 151 | zoz | 125 | 132 | 157 | 212 | 4a | ta7 | a6 70 282 ive | 186 | 218 | 296 | 185 | 193 | 228 | 311 | 195 | zor | 238 + oes El peaeA EA} SE) a) cea OES we 120 3e8 | 242 | 254 | 297 | 407 | 254 | 264 | 310 | 427 | 266 | 274 | 323 roma eee ee 185 aga | 08 | 923 376 | sis | 324 | 336 | 392 543 | 340 | 350 | 408 | Forages a pe ny pn pace ne 300, esa | a2 | aar | aoa | 678 | 433 | 44a | sis | 721 | 455 | ez | so7 reels Sela lnStiaci a = 2 8 g 8 56, x: 8 8 SI6 Fe 8 8 58 7 eee eat jean DePth Jams 096 poet eee 4 0 85 | US OO CURRENT RATING FOR L.V. WIRE ARMOURED CABLES INSTALLED IN GROUND BERBER Inauation Maximum Conductor “Temperature Arrangement Copper 25 a5 50 10 95 120 150 185 240 300 +400 500 630 Aluminium 25 35 Notes: ‘Ampere 130 159 er 20 276 313 381 304 453 505 sr 00 119 us a 212 242 260 (355 ne war 151 188 22 251 281 315 384 400 502 86 v9 16 22 251 aut ar 07 430 456 4) Single core cables are aluminum wire armoured 2) Aluminium wre armour is bonded a! bath ends 137 187 197 202 229 388 a4 476 522 659 ase 2 147 17 203 249 207 335 375 a 492 oir 602 56 XLPE, oore 2 169 | 45 | 169 | 177 zor | is | ava | 20 zs | 207 | on | 247 208 | 254 | 260 | 200 se | 204 | 300 | 352 373 | ae | 340 | aae aor | aaa | a0 | 225 44a | 495 | 490 | 467 4s7 | 499 | 500 | 510 su | 550 | sso | sae | am | eat | 6m | 583 802 - eo | 625 | oo | - | 76 | 96 ee an tat Pe ass | 194 | 137 | 162 tea | is0 | tee | tee za | tr | am | ze | 2a 24 239 | 273 | | ao | a0 | ate ae | 200 | am | 220 ais | aos | ant | avo | 3e7 | 392 | 300 | 404 faa | 439 | 403 | aaa aa7 | 500 | 436 | 463 ama ss7 | 492 ale i eh |pea Teel ales emes|— 7) 43) Values of steel wie armoured cables may safely be applied to steel tape-armoured cables 4) When cables are arrangod in fat formation thay are spaced by ane cable dameter. mney SR BASED ON DIN 57 298 PART 2 VDE 0298 PART 2 ‘TABLE 2 CURRENT RATING FOR CABLE INSTALLED IN AIR =0,6/1 kV. BEBO pct XLPE Insulation Cable Type Na yysNyowy® Nealaxv Non \oE 0271 /1EC 502 Vor 0272 ec 602 Max ie asic oe toneucor ‘emporio ° arangoment | @” | @ Geel Copper | Ampere 15 2 | ~ |ws| ~ | 3 | m | mn | m | m | 2 | mw | ow | 2 28 sla |e a |u| = | 2 | |e |e | 2] & | 2 4 «| | % | a | as | ot | a | wo | oo | or | a | aw | os 6 sa |a | [ae | or | cs | we |e | | 2 | | | in 10 7 | os | 0 | o | | | in | w | | | 7 | 6 tos | a9 | co | 9 | too | tm | as | a | iis | ts | oo | soe | 10 25 40 | i | wos | tia | 137 | tse | se | 20 | 155 | a7 | ta0 | 39 | 473 35 ama | as | a1 | 45 | 109 | 496 | 4s | t57 | 190 | 218 | 60 | 470 | at2 so | 212 | 176 | 180 | 17 | 205 | 250 | a77 | to2 | 202 | 266 | tos | 200 | 250 70 200 | 22a | 202 | 224 | 251 | 20a | 22s | aee | zoe | aoe | zer | ass | 220 5 sai | 2m | za | an | 221 | 37a | zz | aoe | ace | ate | aos | 6 | 400 vo | san | ata | 252 | at | ave | az6 | aie | gar | azo | aer | ase | cot | ari 10 | aaa | 61 | sz | 61 | 20 | 00 | aes | ooo | ase | sso | aor | ase | ont 15 | sit | iz | ari | ara | oe | oro | azo | aso | Seo | 640 | 400 | cor | exo za | iz | aaa | a6 | 42s | soo | os | aoa | c4s | ooo | 77 | ssi | coo | 100 300 | 707 asi | 549 | 673 | oo | sso | ozs | 771 | soz | 06 | car | 04 ao | aso | = | seo | 57 | 17 | tooe | 05a | 736 | 17 | 1270 | 46 | o10 | tow so | tooo |= tao | 940 | 1429 asi | tose | tas | = | goa | 1173 «0 = | 7 = fess | ae} = | = | ose | tase |= | = | stir | tee Aruniiam | ampere z= |w]o || - | - [ajo | - | - | wr | mo] - | - 3 vas | ma | oz] sis | adn | 498 | a | azo | sar | tee | tae | sar | 109 so | te | 138 | ze | age | 160 | tor | a5 | 140 | 00 | 206 | s47 | 161 | 200 70 zs | ae | tee | za | 202 | 24a | tza | 209 | 228 | 252 | te | 205 | 254 $5 zm | 210 | 10 | 210 | 240 | aor | 2m | 2a | 201 | 320 | 22 | 250 | 319 com ea mamma oo eee lean leermberernelesr leon eaoen fsase 150 | sor | 2 | 252 | 2ei | 00 | 207 | 200 | a | are | azo | ome | act | a0 1s | at | se | 200 | 220 | see | ar | o2s | ser | 42s | Smo | sr | aos | ane 20 | 404 | ava | 300 | 378 | 400 | ou | sor | a26 | soz | cos | aos | a7o | oes ao | sas | = | arr | 4a | sao | 2a | a0 | 450 | oz | oso | sor | S10 | o7s 4oo | ese | - | aaa | 525 | a2 | 7as | sta | sos | 720 | o30 | saz | ox7 | 700 so | re | eos | 7a | ort | e7s | 035 | oes | - | 740 | 026 Tabi for [erat 0 wo | | | | | w | | w | wo | w | w | wo | w crop | roe) | 2 |e] | n |u| 2] a2] nu} nla |e] fin 4) For ai temperature 2)Eorgr 7 3) For (A) YOWY only columns 2 to 4 4) Current rating in de 5) To 240 mm accarding to CENELEC, see Publication 6) Three phase curent USS TE CURRENT RATING FOR L.V. WIRE ARMOURED CABLES INSTALLED IN AIR EEE BROOD Insuation Maximum Conductor Temperature ‘rangement ee Copper Ampere 25 wo | 12 | ut | 122] 459 | 159 | 195 | 144 | 170 8 15 | 159 | 473 | 150 | 472 | aoe | 405 | ter | air 50 | 16¢ | t90 | at | tea | 207 | aor | 201 | zz | 260 70 | 208 | 230 | 262 | 200 | 261 | 205 | 254 | 203 | azo 95 2a | 287 | aie | 270 | 318 | 356 | a1 | os | 390 120 zor | 220 | 26s | a2a | 35 | ar5 | 62 | 400 | a8 150 avo | art | aor | 372 | aio | asa | ats | ast | cor 185 ava | sig | aso | 42s | aa7 | 510 | are | ste | 570 240 435 | 44 | 512 | 492 | ss | 501 | s40 | 606 | eso | 300 47s | 536 | sso | sso | 60 | ox | 623 | 6a | 712 ‘00 sia | eza | a7 | 638 | 609 | 726 | 705 | 775 | a0 500 - | o92 | ox | = | 777 | ree | = | ese | 00 830 rar | ras | - | 043 | 895 s75 | oa Aamir ja 25 eee cat ee to eos eee a= 35 sos | 124 | toe | tt | 134 | 150 | 126 | 144 | 167 50 sz | wo | see | 130 | 160 | 104 | 152 | 173 | 205 70 1e2 | 15 | 203 | 178 | 209 | 220 | ao | 219 | 255 95 sea | 222 | 245 | 21s | 244 | 277 | 206 | 250 | 308 120 2a | 256 | 206 | 249 | 203 | 32a | a75 | ato | 960 160 2s | 209 | 312 | 265 | 320 | 352 | a | a5 | a0 185 aor | a6 | ao | 25 | 963 | 306 | a5 | aoe | az 240 sxe | ae | 399 | 96 | 226 | 459 | ace | 475 | 500 300 ari | a3 | 4ar | ase | ara | 405 | 499 | 505 | 550 400 aa | ase | 503 | sos | sss | 570 | 575 | ots | os2 500 - | ser] ast | = |e} ote |= | em | ese Table or " wa} ww} wo] w) w] wo] w] | 10 Groupe Teble for 2 wf] nfoafa fo af ef fon Fecler Notes 41) Single core cables are aluminum wire armoured, 2) Aluminium wire armour is bonded at both ends, 3) Values of steel nire armoured cables may Safely be applied to stool ape- armoured cables. '4) When cables ere arrangod in Nat formation ney are spaced by ene cable dana CUO Na TABLE 3 RATING FACTOR FOR CABLES INSTALLED IN GROUND 2S 2 Sees Se See 0 peer | pee coun tnamal resistivity “Com tenpembre | Tonpertie [ay = a 7G Joa factor toa factor toad tacr | 0 cc %c | esaloselarofoes| co) o60|060'970|035|100| o8olaedioz0|ass|100] 95, oo 5 1.24]12|sso]s33|sor| 421|109|s07]100|190| os9/osslos7jossloay) 09a 10 .2a|129|126|521]405| 402|107/105|101]098] osrloscloss|asslaos] 03s 15 | saifrarfisa|uee| sos] 107] 108|102/199}095| o9s|osajoszlosr|aso] oe x | st0frasfus2|s|100] 105|1,00100|120)039] oszlosifosolassfose| ost s 192|1¢0|0se|054J090] osoloseloar|assfans| 07 » | o9s\osi|ae0| oe7losslostlosajosi| o75 = osalavojoral 072 © | 8 3 5 127] 123[120|1%4|100] _122|s0)s07]104]100| aso|ozelear|oaslaca] ae t© | s2sfsaslssz|asa|s0%] so]07/100|101]007] aarlossjastloezlaos] oss 15 | s2}ssafi1s|s0e|100] 107/105]103|199)085] ose|osefoze|aso|oss] one 20 4,20/1.17/1,13]1,07/1,.01] 4,08] 1.03]1,00|1.97]092| o91|osoloaaloe7|oas| 0.78 ~ lossloas|oee| 6s|0e4joaa|aerjara] ae 6 | j0,a0|0,77)0,75| 0.68 « ose 7 5 ‘2afiz|iza|135|10 138 1.21|:.09]s04 100] osloseloarlass|ozs| oan 10 | 27|taaissa}aa|r68] 114/166|106|101]097] oas\oss|as4loaz|oas] ose 1s | s25fsailssz|a9|r63] s00|s06|123)099]oe] o9a,osojoetloaslaas| aro a el el) 80\0<9/087/oas|oas] a76 3B | +1.03| 1,00]0,97/0,93]0,88) 0,87 /0,26|0,a4 O72 ~ losilanaloss| o24| 022/020 se we | lozrjarslore| ons « oso | RIYADH CABLI —o USS aera CE TABLE 5 f2 GROUP FACTOR FOR CABLE INSTALLED IN GROUND TREFOIL FORMATION CONSTRUC- | numberof Ground thermal resisiviy CW STON system o7 40 15 Z| XLPE cable load factor load factor load factor toad factor osjos{or| os|oslor| os|os|or| o5| 06| 07 1 199 | 1,08/099/ 1.11] 405] 1.00] 1.13] 107] 1.01] 4.17] 108] 1.03, 2 0.97 | 090 | 088 oa1| 0.5] 1,00/0.92|086| 102) 094| 087 | 3 0.98 | 0,80 | 0,74 [092] 075} 0.90 082| 0,76} 092 | 083/076 4 0.3 | 0.75) 069 076/070) 085/077|0.70| 082) 0.7a| 071 5 079 | 0,71 | 0,85 72/066} 0.80/073/066| a1 |a7a| 067 6 076 | 068 | 0,63 093/063 | 0.77 070/063) a.78 | 0.70) 064 8 072 | 064 | 0,59 085) 059} 0.73 /085| 059) 0,74 | 068| 0.59 10 069 |0.61/055| 069/062] 0.56] 070/062] 056| 0.70| 063| 057 construc.) numberof |_| Ground thermal rasistiviy‘C.miW | ince st or 10 15 Pvc cabie od factor load factor teat factor load factor os |os|o7| o5|os|o7| os|os|o7| 05 |0s| 07 1 191 | 4.02/099| 1,04] 105] 1,00] 1.07 | 1.06] 4.01] 1,11 | 108 | 4,01 2 094) 088/084) o97|o91|085| 099/092| 086 1.01) 093/087) 3 086 |0,79/ 074] 082/081}0,75| 0.80 | 083] 076] 0.91 | 043) 0,77 4 082|075/069| 0,84] 076|070| 085|077/071| 0.96| 078 0.71 6 078} 071/065] 0.90/ 072/066 0.80 |0,73/066| 0.81 | 073| o67 6 075 |068/062| 077/068] 0.63] 0,77 | 0,70/n6«| 0,78 | 0,70| 0.64 8 071 064/058) 072 065|059| 0,73 | 065] 059] 0,73 | 066 10 os |os1}oss| 059) 062] 058| 0.69 0.3 Ze Ze construc: | umber of ‘round thera resis C mi ‘ TION ia o7 10. 45 25 a load factor load factor load factor load factor os | 4.9 085 | 1.0 os | 10 oas|10| | 1 | 093 | os? 0,93 | 087 0,94 | 0,87 0,94 | 0,87 2 | onlon a azlors| | o70|az1 3 oer | os 087 | ost 068 | ot 0.68 | 0.61 4 a2 | 050 062 | ase a2 | 058 083 | 050 5 0.88 | 0.52 oss }osz| | 088 | os2 089 | 0.52) 6 085 | 050 058 050 56 | 050 056 | 050) 8 0,51 | 0,46 0,52 | 0,46 | 0.52) | 0.46 0.82 | 0,46 | 10 0.49 | 044 049 | 0.44 049 | 0.44 049 | 044 USS kV TABLE 6 f2 GROUP FACTOR FOR CABLE INSTALLED IN GROUND TREFOIL FORMATION BE es se) == covstruc coun hema sym deal einai 07 40 45 25 "Pei fdas | better | ttc | To tr esles|ar| oslos|ar| os |oslar| os | os |a7 | i 1 | s08|10e/os6) a1 10s) 00] 199 sor) vor] var 10810 i 1.01 | 0,94/ 0,69] 1,02 | 0,95} 0,89) 1,04) 0,.97|0,90 | 1,06 | 0,98 | 0,91 f 2 | oselosr|oai) oss eas |aaz| aor oso |oaz| 000 |os0| ass + | esi |ase)o7e) 092 |ase|o7| 090 @es|o70| 098 aae|o70 + | ase|aso|are| oso est |a7s] 020 |oc2/are| oat |oas|a7e | ¢ | ase|or|a72| or |or|a73) om |oa0/ara| one |oas aru 2 | oms|ore/a7e| o0« oz |a70) oas arora] ose laze| on 10 | 081 |o74 068] 082|074}068| 083] 0.75|068| 0.84 0.76 | 069 ‘Ground thermal resistivity ‘C.mW nun system 10 45 25 J Pic Cn | fedtecer | oaateder | ——wafacer os [ss |or| os jas|or| os |os|or| os |os |or . 1 1o2}o9) 104/408] 1.00] 1,07] 1,06) 4,01) 1,11 | 1,08 | 4,01 t zi o95|oa0} 100 Jose] oa | 103|0sr|os1| 108/50 |o92 3 | 0,88 |0,62/ 0.97 088/082! 0.97 |089/083| 0.98 0,90 | 0,84 ‘ ost 078 | 092/085|079| a3] 086/072] avs a7 oo | 5 | 981 0,75] 089 |0,82/0.76 | "0.90 |0,82|0,76| 0.91 | 0,83| 0.77 a 979\073| 087 |o60/07| oes |ost 074] 029 ast |o75 8 | 088) 075/070) oa 077/07 nes |o78 071| 086 078] 072 =| 075/069] 082 |0,75|069/ 0,83 | 0,76 |0,69| 0,84 | 0,76 | 0,70 umber of resishity mW ae yee 7a as aI ood factor toad factor oas| 10| | 09s as | 10 oas | 10 easccie + | 09a |osr 099 as |o7 04 [0387 | 2 og2|o7s| | a2 082 | 075 os | 075 3 o7s |os7 074 074 | oor 074 |037| 4 | o7loss) | 070/084 70 | 068 07 [oss 5 067 | 0.60 0.87 | 0.60) 0.87 | 0,60 067 | 0.60) ee ee ee 8 | 082/056) 02 | 058 062 | 050 02 | 050 10 060 |ass 060 [ose ot jose 061 [oss IZ Tea TABLE 7 f2 GROUP FACTOR SINGLE CORE CABLE @@8008@ INSTALLED IN GROUND FLAT FORMATION [rem z= aS SS ‘CONSTRUC. ‘number of (Ground thermal resistiviy“C.mwW Ton "| _“ssten oF 10 15) 35 XIPE cate | toad fetor Yond fcr toad actor oad factor 2 oslos|or| os laslor| os |as|ar| as |os| or, 1 1,08 | 1,05/ 0,99) 1,13 | 1,07) 4,00) 1.18 | 1,09] 1,01 1.19 | 1,11] 1,03 | 2 101/093) 086] +03 |094/ 067) 108] 095/088| 100 095 | 088 a osz|ae|a77] o¢s|oes|077| 0.98] 086] 078| 09 | 06] 0.70 4 | 088 |a80/075) 080 |o80/073/ 090/ 081078 ost | 092) 07 8 | ost|azs|aso| oes |a7r\070| 087 078/070| oar |o7a\0.71 6 082| 074/067! 083 |075/068| 084 |075/068| 0.85 |0,76| 069 8 | 072/071] 084) oa0}o71) 045) 081 |o72/065| 061 | 072| 085 10 077 | 069/062] 0,78 |069| 063) 078|070\063| 0.79/0.70/ 0.69 a6 6S Se SS as umber of round thermal resitviy‘C.rwW __ ee oe 10 45, 25 PVC Catte 438 factor Toad factor foad factor load factor Geiss [aa ana ical tan eo laRIaR ReaD 1 196 |o.97| 098) 401/401] 100] 4.07] 1.05] 1.01) 1.16] 1,10] 102 2 092] 099/096] 0.96) 094|087| 1,00| 0.95] 088) 1,05| 0,97| 0,89 3 | 088 }084) 077] 091] 085/087) 095 |0.26/ 079) 096 |o87| o70 4 0.86 |0.80/073| 069] 081/074| 090/082/074| 091| 082/075, 5 984) 0,76)070/ 0.85 |077/070| 087 |0.78/071| 087 | 0,79| 0,71 6 082 | 074/068 083 / 0.75/08) 084 |078\069| 085 | 0,76| 0.69 8 079 }0,71/065) 0.80) 0.72065) 081 |0,72/065| 081 | 0,73] 066 079 |0,70| 069] 073 | 0.71| 064 i o77 number at ‘system a load factor oad fector load factor os | 10 085 | 10 os | +0 | 1 0.91 | os. 092 | 0.86 092 | 08 a or |o71 o78 |o.71 0.78 | 0.71 3 069 | 062 og |os2| | 068 | o62 4 065 | 050 065 | 0.58 085 | 0.98 068 | 0.58 5 dst | 055 ost | 08 062 | 058 082 | 0.55, 6 059 | 0.58 060 | 0.53, 060 | 053, 0.80 | 0.53 8 os7 | ost os |o51 087 | 051 057 | 051 10 055 | 049 0.55 | 0.49 055 | 049 0.88 | 049 CMs ae TABLE 8 f2 RATING FACTOR FOR THREE CORE eee CABLE IN THE GROUND IN FLAT FORMATION " CONSTRUC- | 5 umber of Ground thermal resistivity CW jcc a ener or 10 25 XLPE cablo | Toad facior load factor load factor load factor as |ce|o7| os |oe|or| os |os|or| os | os |or [+ | 12|1o0]o0e) 106] 105) 100] 109/106) sor | 141 | 107) 102 2 | 096/090 |084| 098 |001|o8s| 090 |osz]oes| 101 |ae4|asr \ 3 0.86 |0,80/0,74) 0,89/ 081/075) o90/083/077, 092 | 084) 0.77 4 | oge/a7s/aee| oss|a7e|a70| o9s|a78|071| a6) 078 |072 s | o7e/azs|a65| 090 |a72|a86| 081 |a78| 087] 082 | 074|087 « | 076 /08\a69| 077 |a0e|058| 078 /070/004| 070/071 |088 8 a72|0¢s|0s8| 070 098/060) 074 |068 |o00 o71 | 084 059 056| 069 |062|055) 070 |063|057) 071 |063|057 10 68 | 061 CONSTRUC- | numberof Ground thermal resistivity C.mW 2 pin ay o7, 40 15. 25. PVC Cabie toad factor Toad factor Yo factor Toad factor os |oslor| os |os|o7| o5|oelor| 05 | 06 | o7 1 oat |oe2|o94| 097 |osr|1,00] 104 [03] 1.01] 1,13 | x07 | 1,02 2 086 |087/085| 091 | 090/085) 0.97 |0.93/087| 1,01 |094 | ose 3 082 | 080/075} 0.86 |092/0,76) ast |o.84]077| 092/084 | 0.78 4 080 | 076/070) 084|077\0,71) 086 |0,78)072| 027 | 0.79 | 0,73 5 0,78 072/066} 081/073 |067| asi 0,74 /068| 082 |0,75 | o68, 6 076 | 03/064] 0,77 |0,70|0.64) 078 |0.71/065| 0,79 | 0.72 |a65, 8 0,72 |088/059| 0.73/06 /080| 74 |0.57\061| 075 | 067 | 061 10 0.69 | 052 | 057 071 |0,04}058) 0.71 | 0.64 |0.58 Ground thermal resistiviy'C.ruW coystruc- TION 10 15 25 | Al Toad factor Toad factor | load factor Toad fector | | cas | 10 | oas | 10 ars | 10 cas ||| 1 0,94 | 0,89 0,94 | 089 | 094 |o89 0.95 | 085 | 2 O77 | 0,72 0,78 | 0,72 0,78 | 0,72 0,79 | 0,72 | : 3 060 | 062 oe | oee a9 | 0.62 069 | 062 4 063 | 0.57 0.63 | 057 063 | 0,57 oes|os7| | + | esoless| | asofoss| | ese lass] | avo fess] | 6 056 | 0.51 0.56 | 051 os7 |0.51 osr fost] | 8 082/047 ose oar) | 052 |a7 059 | 047 10 | 049 [os 050 | 044 090 | os 00 | oe Sa a TABLE 9 GROUP FACTOR f2 FOR CABLE @0e INSTALLED IN GROUND FLAT FORMATION [rem CONSTRUC-| numberof Ground tema resist mW __ Ton system oF ia 15 25 PVC Gabe Jona factor loa actor Jona factor load tacor os|os|o7| os|os|o7| os|os|o7| 05 | o6|o7| 1 a0 | ost] 099) 098) 090] 1.00| 1.05 | 104/103) 1.14] 1.00] 1.00 | | 2 085/085] 085| 093) o82/089/ o88|095|000| 1,03) 096| 090 a oo | 0.70] 078) 087 | 086|080| 03 | 0.88, 080) 095 | o87| oat jee lan bas Smee eae ames le 5 075| 076) 070| 088 077/071 os |o77\0,71| 085 o78| o72 5 073 | 073) o67 089 | 075| 069 8 | 070|099| 069 078 | 071| 064 075] 067| 061 CONSTRUC- ‘Ground thermal resistivty‘C.miWw TION system | ov al 15 25 PVE Cable Toad facor Jom factor Ton factor oad factor | oss | 10 | os | 10 0.85 | 10 | 095 | 1.0 1 096 |oo1 096 | 031 a7 | oat osz los] | 2 ons | 070 02 | 076 082 | 076 osa|o76) | 3 072 | 088 072 066 073 | 068 o73| 086) | 4 087 | 0.81 o67| 061 0.68 | 0.61 coal ost) | 5 0.63 | 0.57 0.63 | 0.57 | 0,63 | 0.57 064 | 0.57 | 6 480 | 058 0.60 | 0.55 081 | oss ost oss) 8 06 | ot 056/051) | 057 |os1 ost lost) | 1 | 083/048 058 0.48 058 | 048 058 048 TABLE 10 RATING FACTOR FOR DIFFERENT AIR TEMPERATURE : 2 falalsfelr|alelw[alala | CONSTRUC- | conductor | ntientemporture NsTR nt Ambient temperate © wo | as] 2 | 2 | 2 | as | a | a | oo | os | c =| Pe [spend | eee | XUPE cable | 45 | 12 | 108 | 104 | 10 | 096 | 091 | o97 | 082 | 076 | ars Pvccable #5 | ass | 114 | 110 | 105 | 10 | 095 | 099 | 089 | 076 | 068 | a60 | PVC Cable 70 122 | 117 | 1.42 | 107 | 10 | 094 | o87 | 079 | 071 | 06 | 050 1) 2.& 3 core cable in one phase and in d.c. system rer CUES aso oO I DIN 57 298 PART 2 VDE 0298 PART 2 TABLE 11 GROUP FACTOR F2 FOR CABLE INSTALLED ON CABLE TRAY Cable installation rer tei me cl ferent wae ae 0.92 0.98 0.88 No. of | 4 | LAID. ON TROUGHS (RESTRICTED AIR - 0.92 0.99 0.88 foe er | eee lee le 2 | om | ow | oat i) ee | ue | ae wot a Ss ; CABLE RACKS: 1 1.00 0.97 0.96 g eee so >| om | os | ase | | 6 0.94 0.91 0.90 a, net | ee | ARRANGED ON alee STRUCTURE ORON THE WALL | 0.94 091 098 GROUP FACTOR | [cree CURSO a DIN 57 298 PART 2 VDE 0298 PART 2 TABLE 11 (CONTINUED) raat jameter ton he grou | (ass | om | ose | oof | rouse | twwon reoucns | | | (RESTRICTED AIR ‘) Ces | || eS GrreULATION | 2 | ow | oss | oss a | ow | os | oa | 6 os oat | ore | No.of | raske LAD ON ag 1 | 190 | ose | ove 2 | 190 095 | oss 2 | t00 | om | ose © | 1 | 093 | 080 | | of tt i formation 2 i: cenour racror oa | oss | oss | Rove actor canbe considered = USS DIN 57 298 PART 2 VDE 0298 PART 2 TABLE 12 GROUP FACTOR F2 FOR CABLE INSTALLED ON CABLE TRAY No.of eable side byside laid on the ground 095 | 090 | oas | oss | ose No.of Troughs, LAID ON TROUGHS | 095 | 090 | oss | 08s (RESTRICTED AR | 04 CIRCULATION) 2 1 090 | 085 | oss | ost 3 6 No.of Racks LADD ON (GABLE RACKS 1 190 | 098 | 095 | 093 | 02 2 190 | 095 | 093 | 090 | 09 3 400 | 094 | 092 089 088 6 400 | 093 | 090 087 086 080 a3 | oss | ost | o79 | 078 oss | ost | o79 | o77 | 076 No. of CABLES an vo ARRANGED ON STRUCTURE OR 100 | 093 | 090 | 087 | 086 ON THE WALL. GROUP factor can be considered = 1 RS a DIN 57 298 PART 2 VDE 0298 PART 2 TABLE 12 ( CONTINUED ) ee Cee g No. ofeable side | bysde laid on the grounes | No.of Troughs! LAID ON TROUGHS: | (RESTRICTED AIR CIRCULATION) a 3 | 6 No. of Racks LAIDON CABLE RACKS. 2 a 6 No. of CABLES. No.of CABLES, GROUP factor can be considered = 1 OTe area DIN 57 298 PART 2 VDE 0298 PART 2 TABLE 13 CONTROL CABLE Cable core size should be from 1.5 to 10 mm” | 0 ox0 No. of cores tei in ae the ground | 5 070 075 7 060 065 08s 4 04s 0.50 9 0.40 045 24 035 040 0 020 035 6 0.28 030 1) FACTORS TO BE USED WITH TABLE 1 COLUMN 4 FOR INSTALLATION IN THE GROUND TABLE 2 COLUMN 4 FOR INSTALLATION IN AIR. CUS Oma ru TABLE 14 MAX. SHORT CIRCUT CURRENT FOR COPPER CABLE AT 1 SEC. BEREonooe rea atine| aT of short MAX | CIRCUIT TEMP AT | CONDU. | nora | crow , OPERA. | MAK, TION. Temp, | 90 | a0 | | Shor circuit curent Amn? Soft sivor | ‘connection > | 60 | 100} 18} 115) 10] 122] 129] 136] 143] 150 XLPE Cable so | 720 | ma) to] s54) 157] 150] 165] 170/170] 101 fc “co | a5 | a | 7} 6] | so | a] a] 20 PVC CABLE << 300 mim 8 160 | 104] 103) 115} 119 | 122) 129] 196) 143] 150 > 900 mnr® 85 vo | 9 | 103) 107] tor} 11 | te] 126] 193] 140] | Teer Isc for time (t) can be obtained from the following formula Is Isc.(1) vt Where: Isc (1 hort circuit current at 1 sec. ST TABLE 15 MAX. SHORT CIRCUT CURRENT FOR ALUMINIUM CABLE AT 1 SEC. SeEn86 Conductor temperature atthe beginning of shor cut COND, | SHORT MAX. | CIRCUIT TEMP.AT) CONOU- NORMAL CTOR m| 7 | 72 | o | a | | 95 as | a8 Bs OPERA. MAX. | tion. | ter | 90 | 9 | 70| 65 | 6 | 50 | 4 a0 | 20 3 . ‘Shor cheuit current Amn | XLPE Cable 2 | 250 ge | 102) 104! 105) 109} 113) 16] 120 ci € so} 7m | 6 | 6 | 50) | 30 | 2 PVC CABLE. | | $300 mn? 85 160 ag g 2 a > 200 mm® 85 TRE CO VoL CTE LAYING INSTRUCTION PERMISSIBLE BENDING RADII Minimum bending radius as a multiple of completed cable diameter: TYPE OF CABLE MULTIPLYING FACTOR Single-core Multi-core Non-metallic shielded 15 12 (VDE 0298) Permissible pulls When laying power cables by machines, par- ticular attention must be paid to the permissible tensile forces. The formulae for obtaining these are given in table underneath. pulling Construction tensile ‘method of cable force paling head all ypes of cables F=A(60N/mm2) onthe (cable with Cu conductor) conductors (20N/ mm?) (cabo wit Al conductor) with pling allwie armoured cables stocking Jeg. NYFGY, NYFGYBY, et) (Ou (AL) /PVC (xLPE)/ SWA/ PVC ‘A= Total conductor cross-section in mm? (without screen and concentric protective conductor) D = Outside diameter od cable in mm. If three single-core cable are laid simultaneously with a common pulling slocking, three cables are Used in the case of three laid up single-core cables as the basis for determining the permissible pull and two cables in the case of uplaid up single-core cables. AL GUIDE Ua LOW VOLTAGE SINGLE CORE CABLE (IN TREFOIL FROMATION ) LINEAR RESISTANCE , REACTANCE AND VOLTAGE DROP OF PVC INSULATED ( 85°C ) COPPER CONDUCTOR ve 1599 os | ts | eta ms 20 ous | ea | ta04 208 er ors saa 183 280 ose 20 | ae | 115 1444 0.124 1449 | 243 ome | com ons | osm | 0m ee oe om | aS | nal oe | caw ows | asm | ose ows | oa oa | ozs | ome | ora | ona oi | ote | oars ower | ora oo | ote | oar ors | oour oor | crm | oz | como: | oars oo | aime | 0200 oa ce on ee | acne | 001s oo | ore | ones | aa EE re Es ees R(DC) : DIRECT CURRENT RESISTANCE AT 20°C 20 R(DC) ; DIRECT CURRENT RESISTANCE AT 85°C. 85 R(AC) : ALTERNATING CURRENT RESISTANCE AT 85°C. 85 x REACTANCE,Ohm / Km 2: IMPEDANCE, Ohm / Km. VD: VOLTAGE DROP, / Amp. km RIYADH rT Tae ea | LOW VOLTAGE CABLE (MULTI CORE ) LINEAR RESISTANCE , REACTANCE AND VOLTAGE DROP OF PVC INSULATED (85°C ) COPPER CONDUCTOR 15 2a 1819 1519 16s 22 J 2s za | a0 920 ons so | 40 461 s19 578 012 an | eo | 308 sar ae ora 540 10 199 20 220 09 3x0 | 8 118 144 aut 06 se | amt 2 over oot oars | oma oasis tor % ose ssa ose 098 ses 1014 FA ose oes over o.0%8 ose orm co 0.288 os | osar oss oast ose 9 oa za oes os ost os 120 0.189 outs ote ost or ea 150 0128 0.156 0.188 0.091 0.182 os | 185 coset | axa | osre oo see oan | 20 corse | acser | oowre 0% oe az 200 caso: | cores | cone co | ova 708 400 coo | cosse | cose 089 aves ona 200 coves | 0049 | 005s | one o.1014 0361 ; 630 0.0283 oss | aoa 0.088 0.0872 oa (OC) : DIRECT CURRENT RESISTANCE AT 20°C 20 R(DC) : DIRECT CURRENT RESISTANCE AT 85°C 85 R(AG) ALTERNATING CURRENT RESISTANCE AT 85°C Bg REACTANCE,Ohm / Km Z —:_ IMPEDANCE, Ohm / Km vD VOLTAGE DROP / Amp. km RIYADH C. aon Bes US aa sO LOW VOLTAGE SINGLE CORE CABLE (IN TREFOIL FORMATION ) LINEAR RESISTANCE , REACTANCE AND VOLTAGE DROP OF XLPE INSULATED (90°C ) COPPER CONDUCTOR 2 eee rote reese ec ce : =e EES eres esl See a ene ete farce nan wee] zi cae ee es | = ec nee re ae tae 120 0.195 0.197 0.100 zai osr7 | a i ST | om | 300 0.0766 oosiz 0.096 oie | oz | a aera eran laa | 500 0.0487 0.0513 0.094 0.105 | 0.167 5 7a EEE ete eee | Ripe) : DIRECT CURRENT RESISTANCE AT 20°C R(DC) DIRECT CURRENT RESISTANCE AT 90°C RAG) : ALTERNATING CURRENT RESISTANCE AT 80°C x REACTANCE,Ohm / Km 2: IMPEDANCE, Ohm / Km. 7) VOLTAGE DROP / Amp. km Ta LOW VOLTAGE CABLE (MULTI CORE ) LINEAR RESISTANCE , REACTANCE AND VOLTAGE DROP OF XLPE INSULATED (90°C ) COPPER CONDUCTOR 35 0.524 0.688 0.669 0.098 0.676 1.03 |i an ana meas cea | 400 | 0470 0509 con98 0.908 0.1004 one R(DC) : DIRECT CURRENT RESISTANCE AT 20°C 20 R(DC) : DIRECT CURRENT RESISTANCE AT 90°C 0 - (GG) : ALTERNATING CURRENT RESISTANCE AT 90°C Xo: REACTANCE,Ohm / km 2 IMPEDANCE, Ohm / Km vb VOLTAGE DROP.Y/ Amp. km RIYADH CABLE: EUS Ga LOW VOLTAGE SINGLE CORE CABLE (IN TREFOIL FORMATION ) LINEAR RESISTANCE , REACTANCE AND VOLTAGE DROP XLPE INSULATED ( 90°C ) ALUMINIUM CONDUCTOR R (DC) R (DC) C P z . 20 90 90 cn 18H 280 289 24 282 3522 2 120 1509 1.599 outat 1.54 2280 36 808 119 saa | oats ite 1.662 0 oes onze onze oan onze 125 70 oss sca oscs | 0105 ose 05 6 as20 ato oat autos ozs oer? 20 0259 axze 005 o.to0 oto ose 150 0206 aes oes o.to0 zea oars 185 oes oz oz 080 ox 0365 240 ars 160 x62 057 180 0225 200 100 oz e130 0.056 tee 280 200 ore e100 os02 oe) 0209 s00 0.0605 ore 081 ose ozs ee 630 0.0469 0.060 0.064 oo | oan 0.183 LOW VOLTAGE MULTI CORE CABLE LINEAR RESISTANCE , REACTANCE AND VOLTAGE DROP XLPE INSULATED ( 90°C ) ALUMINIUM CONDUCTOR Spas R(DC) J R(Oc) § Rac z M 20 ) 7 6 191 249 2481 2 120 | 1590 1i2 2240 | nee tats sant 1.604 50 ost | 0.822 0.828 1.241 10 oats oes ast 80s 8 0320 | 0410 0.421 0.666 120 oss oat 097 sts 180 one oz | 0.280 sa 185 ore o210 230 ser 240 0.125 0.160 0.185 | 0.318 00 o.to0 128 ose ars 00 aarre 100 ots az 00 .ceos ore 001 0.068 20 208 «0 ssa ceo oes 088 e109 180 Rig) Direct Current Resistance at 20°C, Ohm/Km x Reactance,Ohm / Km epey Direct Current Resistance at 90°C, Ohm/Km z Impedance, Ohm /Km_ (AC): Atemating Current Resistance at 90°C, Ohmi VD : Voltage Drop (Phase to Phase), VIA 0 The required sizes of cable shall be selected based on the following steps : Ampacity : Based on the required ampacity and the installation condition, a suitable size of cable shall be selected Voltage drop : The suitability of the above selected size shall be cross checked with the voltage drop. If it is within the limit the selection is O.K. Otherwise the higher size (whose voltage drop suits the requirement) shall be selected. Following is an example for the above Example : 150 meters of three core cable, XLPE insulated, PVC sheathed, copper cable installed underground to carry 100 amperes load, supply voltage 380 V, three phase system 60 Hz, Ground temperature 40°C, soil thermal resistivity 2.5 k m/w and load factor 1 For 35 mm* cable, From table 1 of this catalogue the ampacity is 173 Amp. Derating factors: Soil thermal resistivity and ground temperature (Table 3) = 0.68, Group and load factor (Table 8) =0.89 Therefore, the derated current is 173 x 0.68x0.89 = 104 Amps, which satisfies the requirement, Verification of Voltage Drop : Voltage drop Vap = Vex 1000 XV. y 79 jkr sae Ix L x 100 Vp Maximum permissible voltage drop (say 2.5%) Vv System voltage (here 380 Volts) L = _ Length in meters (here 150 m) 1 = Current (104 Amp) 2.5 x 1000 x 380 Therefore, V,,= VIALKm 104 x 150 x 100 = 0.609 V/A/km From table on page # 23 of this catalogue, the voltage drop of 35 mm? XLPE insulated multicore copper cable is 1.03 V/A/Km, which is much higher than the requirement of 0.609 V/A/Km. The voltage drop of 70 mm’ cable is 0.574 VIA/Km which is within the limit. Therefore, the suitable size is 70 mm”.

Das könnte Ihnen auch gefallen