Sie sind auf Seite 1von 43

ZXUR 9000 Product Introduction

ZTE University

Contents

General Introduction
System Architecture
Hardware Description
Product Highlights

ZXUR 9000 Location in Mobile Network


ZXUR 9000
MSC-S/VLR
Nc

BSC/RNC

Abis

GMSC-S

PSTN

BTS
A/IuCs

Abis/Iub
BTS/NodeB

Mc

Gb/IuPs
Iur/Iur-g
MGW

Abis/Iub
BTS/NodeB
Iub

BSC/RNC

Other-PLMN

Nb
GMGW

A/IuCs

Gb/IuPs

NodeB

CS/PS Mixed Data


Signaling

SGSN

GGSN

CS Data
PS Data

Functionality of ZXUR 9000 in General


BSC/RNC Basic
Function

Node B
Abis/Iub
ZXUR
9000
Node B

Iur-g
ZXUR
9000

System information
broadcast and MS access
control
Mobility management
such as handover,
relocation, etc.
Radio resource
management such as
power control, cell
resource allocation, etc.
CS and PS RAB services

Node B

GERAN/UTRAN

Radio channel encryption


for transmitted data and
signaling

Physical Specifications
Item
Dimensions (H*D*W) (mm)
Weight

Specification
2,200 * 800 * 600
Empty Cabinet <110
Full Configured Cabinet <490

Power Consumption

Single Shelf < 3500

Power Source
Requirements

-48V DC (-57V DC ~ -40V DC)

Operating Temperature

Long-term temperature: 5C40C.


Short-term temperature: -5C45C.

Operating Humidity

Long-term humidity: 5%~85%.


Short-term humidity: 5%~90%.

Design Based on ZTE Common Hardware Platform


CSCF
AGCF

MGCF
MME
PDN-GW

All IP Platform Design

MGW
BSC

GSM/UMTS/CDMA Co-Platform

RNC
USPP

BSC/RNC/CN Co- Platform

SGSN

ServingGW

GGSN

PSS/PES

AGW

IM-MGW

PDSN/HA

Converged OMC Platform

Convergence

BGCF

MSCs/MSC
e

Common platform enhance board integration, system stability and save spares
GSM and UMTS networks share interfaces and transmission, saving cost
Unified OMC simplifies O&M, saves manpower and unifies GU capacity planning
Resource pool, flexible GU resource allocation
Unified RRM realizes intelligent access, handover and GU load balance

ZXUR 9000 Rack Components


Power distribution sub-rack:

3U height, in top of the rack

Provide power distribution for the


whole system, power indication and
outer environment monitoring
function

Extensio
n subrack 1

Dual power input, support automatic


switch between 2 power input

The rack:

600mm width*800mm depth, in line with


ETS 300 119 or IEC60297 standard

Extensio
n subrack 2

2200mm height, support 3 sub-rack


configuration

Sub-racks are configured by sequence:


main sub-rack first, than sub-rack 1 and 2

Main
sub-rack

Wind guide sub-rack:

Provide wind duct


for
forward/backward
wind to isolate the
system wind duct
and improve
cooling efficiency

The wind duct is


below service subrack.

The wind duct for


main sub-rack is
2U height, and for
extension sub-rack
is 4U. Wind duct
for each sub-rack
is placed below
the sub-rack.

ZXUR 9000 Service Sub-rack Introduction


ZXUR 9000 Rack
ZXUR 9000 includes two types of subracks:
Main sub-rack, service
8 handling plus
O&M and clock function, compulsory for

ZXUR 9000 shelf (Front, Rear, Side view)

configuration.
Extension sub-rack, service handling,
configured based on capacity
requirement, configured from 0-2.

19 inch standard shelf

Front and rear plug-in shelf for each subracks, each have 14 slots

Components of each sub-rack (from


top to bottom)

shelves , designed with ATCA standard board

FAN unit (3 FANs, 2 for front shelf heat


dissipation, 1 for rear shelf heat
dissipation)

Processing boards and O&M boards in front

Interface boards and switching boards in


rear shelves

Distributed
design,
pool
Distributed
design,
resource
pool for
for service
service handling
handling ensure
ensure high
high
Plug-in
boards (front
board resource
8U,
rear
reliability, strong
strong processing
processing capability
capability with
with high
high efficiency.
efficiency.

board 9U)reliability,

Power unit (each sub-rack configure 2)

Contents

General Introduction
System Architecture
Hardware Description
Product Highlights

ZXUR 9000 System Architecture

ZXUR 9000 is designed with all IP switching architecture.


Logical units including: access unit, switching unit, processing unit,
O&M unit etc.
ZXUR 9000

Abis/Iub

Iur-g/Iur

Switching
Unit

Access
Unit

BTS/Node B

Processing
Unit

O&M

Environment
Monitoring Unit

BSC/RNC
A/Gb/Iu

Power, FAN
CN
STM -1
E1

FE GE
485

ZXUR 9000 Board Classification


Switching Board

Processing Board

Interface Board

Switching board deals with the switching in


control plane (BASE) and media plane (FABRIC).
Besides the intra-shelf switching, it also provides
switching channels for all inter-shelf
communication.

Processing board handles the protocol processing


in control plane and user plane, and is
responsible for the overall processing and control
in terms of O&M.

Interface board offers access of STM-1, E1/T1,


CSTM-1 via interfaces including A, Abis, Gb, Iu,
Iub and Iur to meet various requirements of
networking.

Switching and Processing Board


Switching Board
Boards

Full Name

Function Description

Conf. Principle

EGBS

Enhanced GE
Base Switch
board

Handles switching in BASE, namely control plane;


provides switching channels for all intra-shelf and
inter-shelf communication in control plane.

The number of EGBS is always 2


for each shelf.
GSM and UMTS can share these
2 EGBSs.

EGFS

Enhanced GE
Fabric Switch
board

Handles switching in FABRIC, namely media


plane; provides switching channels for all intrashelf and inter-shelf communication in media
plane. Provides clock function.

The number of EGFS is always 2


for each shelf.
GSM and UMTS can share these
2 EGFSs.

Processing Board
Physical
Boards

USP

Full Name

Universal
Service
Process
board

UMP

Universal
Management
Process
board

ETCB

Enhanced
Trans Coder

Logical
Boards

Function Description

Conf. Principle

RUP

Processing in user plane; handles the voice and


data processing within system.

CMP

Control plane processing, for common signaling


processing among cells

DMP

Control plane processing, dedicated for user


signaling processing irrelative with cells

OMP

Overall management

OMM

Local O&M

2 OMPs, 2 OMMs.
GSM and UMTS share
the boards.

Support transcoding and rate adaptation.

Apply to GSM only

Capacity decides the


number of USP.
GSM and UMTS should
configure respectively.
DMP is for UMTS only.

Interface Board
Boards

Full Name

Function Description

GSM or UMTS

EAPB

Enhanced ATM Process Board

Offer interface for ATM over STM-1

Apply to UMTS only

EDTA

Enhanced Digital Trunk board ATM


version

Offer interface for ATM over E1

Apply to UMTS only

ESDTA

Enhanced SDH Digital Trunk board


ATM version

Offer interface for ATM over


channelized STM-1

Apply to UMTS only

Enhanced Digital Trunk board IP


version

Offer interface for IP over E1

Apply to GSM and UMTS

ESDTI

Enhanced SDH Digital Trunk board


IP version

Offer interface for IP over channelized


STM-1

Apply to GSM and UMTS

EGPB

Enhanced GE Process Board

Offer GE/FE interfaces

Apply to GSM and UMTS

ESDTG

Enhanced SDH Digital Trunk board


GSM version

Offer access of TDM CSTM-1

Apply to GSM only.

EDTT

Enhanced Digital Trunk board TDM


version

Offer access of TDM E1/T1

Apply to GSM only

ESDTT

Enhanced SDH Digital Trunk board


IP version

Offer access of TDM CSTM-1

Apply to GSM only

EDTI

Abundant interfaces for different networking requirements


Abundant interfaces for different networking requirements

High Reliability Design


Logical Unit
O&M Unit

Access Unit

Switch Unit

Processing Unit

Physical
Board

Logical Board

Backup Method

OMM

1+1

OMP

1+1

EAPB

EAPB

1+1

ESDTA

ESDTA

1+1

EDTA

EDTA

Load sharing

EGPB

EGPB

1+1, load sharing

EDTI

EDTI

1+1

ESDTI

ESDTI

1+1

EDTT

EDTT

1+1

ESDTT

ESDTT

1+1

ESDTG

ESDTG

1+1

EGBS

EGBS

Load sharing

EGFS

EGFS

Load sharing

RUP/DMP

Load sharing

UMP

USP
ETCB

CMP

1+1

ETCB

Load sharing

Signaling Processing Flow-GSM/UMTS

Signaling Processing Flow

Service Processing Flow-GSM(IP A)/UMTS

CS Service Processing Flow


PS Service Processing Flow

Service Processing Flow-GSM(TDM A)

CS Service Processing Flow


PS Service Processing Flow

Contents

General Introduction
System Architecture
Hardware Description
Product Highlights

Hardware System Overview

B1
3

A
1

B2

Shelf

Service shelf
19 inch standard shelf
Front and rear plug-in shelf for each
sub-racks, each have 14 slots
Processing boards and O&M boards in
front shelves , designed with ATCA
standard board
Interface boards and switching boards
in rear shelves

Board parameters

Front plug-in board

Height: 8U
Service processing

Rear plug-in board

Height: 9U
Interface and switching

Configuration

Master shelf configuration


1

Rack Configuration

RNC/BSC
Slave shelf 1
Slave shelf 2
Master shelf

UEUEUEUE U
STSTSTST M
PCPCPCPC P
B B B B
I
N
T

I
N
T

15

I
N
T

I
N
T

17

E
G
B
S

11

13

U
M
P

U
M
P

U UEUEUEUEUEUE
M STSTSTSTSTST
P PCPCPCPCPCPC
B B B B B B

E
G
B
S

E
G
F
S

E
G
F
S

19

21

I
N
T

I
N
T

23

I
N
T

I
N
T

I
N
T

25

27

11

13

I
N
T

Slave shelves configuration


1

UEUEUEUEUEUEUEUEUEUEUEUEUEUE
STSTSTSTSTSTSTSTSTSTSTSTSTST
PCPCPCPCPCPCPCPCPCPCPCPCPCPC
B B B B B B B B B B B B B B
I
N
T
15

I
N
T

I
N
T
17

I
N
T

E
G
B
S
19

E
G
B
S

E
G
F
S
21

E
G
F
S

I
N
T
23

I
N
T

I
N
T
25

I
N
T

I
N
T
27

I
N
T

UMP (Universal Management Process Board)


OMM function
1.Responsible for NE operation and maintenance.
2.Through the rear board EGBS, it externally provides GE
interface to connect EMS.

OMP function
1.Processes global procedure, controls the operation
and maintenance of the entire System.
2.UMP directly or indirectly monitors and manages the
boards in the system and manages the configuration of
each board and other components.

O&M Unit Principle

USP (Universal Service Processing Board)

The USP is a service processing board, including


the protocol processing of control plane and user
plane.
CMP
Common control
plane protocols
processing

USP
DMP
Dedicated control
plane protocols
processing (UMTS)

RUP
User plane protocols
processing

ETCB (Enhanced TransCoder Board)

The ETCB implements the conversion


between the voice codeand PSTN A PCM
voice code at radio interface and the rate
adaptation between the two codes
(including the rate adaptation in data
service).
GSM Only

EGBS (Enhanced GE Base Switch board)


EGFS (Enhanced GE Fabric Switch board)

EGBS: Control plane switching


EGFS: User plane switching
EGBS function
1.Responsible for board
power-on and version
loading.
2.Monitors shelf environment,
including the power,
temperature, and fan status.
3.Implements inter-shelf
control plane switching

EGFS function
1.Distill clock reference and
distribute in the shelf
2.Implement inter-shelf user
plane switching

Switching Unit Principle


Control plane
connection
EGFS Clock Distribution

Uer plane connection

IP Interface Board
----------EGBP (Enhanced GE Process Board)

The EGPB is an interface board for GE access and IP


processing.
The EGPB provides 4 GE (optical or electrical) interfaces.
The EGPB can be configured on each interface of GSM
and UMTS.

IP Over E1 Interface Board


EDTI (Enhanced Digital Trunk Board IP version)
EDTI:
ESDTI
(Enhanced SDH Digital Trunk board IP version)

Provide 32 E1/T1 interfaces

Provide HDLC/PPP/ML-PPP protocol processing

Support GSM and UMTS IP over E1 access on Abis and Iub


interface

EDTI:

Provide 4 CSTM-1 optical interfaces

Provide HDLC/PPP/ML-PPP protocol processing

Support GSM and UMTS IP over CSTM-1 access on Abis


and Iub interface

UMTS ATM Interface Board


EAPB (Enhanced ATM processing board)
ESDTA
(Enhanced SDH Digital Trunk board ATM version)
EAPB:
EDTA
Digital
Trunk Board ATM version)
Provide 3G (Enhanced
ATM over STM-1
accessing

Provide 4 STM-1 optical interfaces for the system

Distill each STM-1 line clock as the clock reference

ESDTA:

Provide 3G ATM over CSTM-1 accessing

Provide 4 CSTM-1 optical interfaces, support 252 E1s


including 168 groups of IMA

ESDTA:

Provide 3G ATM over E1 accessing

Provide 32 E1/T1 interfaces, including 30 groups of IMA

GSM Interface Board


EDTT (Enhanced Digital Trunk board TDM version)
ESDTG
(Enhanced SDH Digital Trunk board GSM version)
EDTT:
Provide 32 E1/T1
interfaces
ESDTT
(Enhanced
SDH Digital Trunk board TDM version)

Provide TDM over E1 access for the GSM Abis/A/Ater


interfaces

Provide TDM/IP processing


ESDTG:

Provide 4 CSTM-1 optical interfaces

Provide TDM over CSTM-1 access for GSM Abis interface

Provide TDM/IP processing

ESDTT:

Provide 4 CSTM-1 optical interfaces

Provide TDM over CSTM-1 access for GSM A interface,

Provide TDM/IP processing

Board Capacity
GSM Mode
Index
PDCH
CS Erl
Cell
BHCA (K)
TRX

CMP

RUP

ETCB

1024
2800
2048

5000
7000
600
-

4800
-

UMTS Mode
Index

CMP

DMP

RUP

MAX PS Throughput(Mbps)

1600

MAX CS Erl non encrypted

9000

4350
1200
120000
120000

2900
65000
65000

34000
8000

BHCA (K)
Cell
Online Subs. (D+F+P)
Online Subs. (D+F)

Remark: D-DCH, F-FACH, P-PCH


For UMTS, The PS index of RUP is based on subscribed MBR 4M, HS896/128 with
2K signaling (UL+DL); the CS index of RUP is based on VAF is 0.5.

System Configuration U 1Single


Mode
2 3 4 5 6 7 8 9 1

1 1 1 1
0 1 2 3 4

Index

One
shelf

Two
Shelves

Three
Shelves

CS

54K

135K

234K

PS

9.6G

24G

41.6G

Cell

1200

2400

2400

4350K

8700K

8700K

BHCA

UMP

OMM OMMR+OMMB

UMP

OMP Global Operation and Maintenance

USP

RUP User Plane Processing

USP

DMP Control Plane Dedicated Processing

USP

CMP Control Plane Common Processing

U U U U U U U U U U U U U U
S S S S S S S S S S S S S S
P P P P P P P P P P P P P P
I I I I E E E
N N N N G G G
T T T T B B F
S S S

E I I I I I I
G N N N N N N
F T T T T T T
S

U U U U U U U U U U U U U U
S S S S S S S S S S S S S S
P P P P P P P P P P P P P P
I I I I E E E
N N N N G G G
T T T T B B F
S S S

E I I I I I I
G N N N N N N
F T T T T T T
S

U U U U U U U U U U U U U U
S S S S M M M M S S S S S S
P P P P P P P P P P P P P P
I I I I E E E
N N N N G G G
T T T T B B F
S S S

E I I I I I I
G N N N N N N
F T T T T T T
S

System Configuration G Single


Mode
1 2 3 4 5 6 7 8 9 1

1 1 1 1
0 1 2 3 4

One
Shelf

Two
Shelves

Three
Shelves

CS

35K

63K

98K

PDCH

15K

45K

60K

TRX

2048

6144

12288

2800K

8400K

16800K

Index

BHCA

UMP OMM OMMR+OMMB


UMP OMP Global Operation and Maintenance
USP RUP User Plane Processing
USP CMP Control Plane Processing

U U U U U U U U U U U U U U
S S S S S S S S S S S S S S
P P P P P P P P P P P P P P
I I I I E E E
N N N N G G G
T T T T B B F
S S S

E I I I I I I
G N N N N N N
F T T T T T T
S

U U U U U U U U U U U U U U
S S S S S S S S S S S S S S
P P P P P P P P P P P P P P
I I I I E E E
N N N N G G G
T T T T B B F
S S S

E I I I I I I
G N N N N N N
F T T T T T T
S

U U U U U U U U U U U U U U
S S S S M M M M S S S S S S
P P P P P P P P P P P P P P
I I I I E E E
N N N N G G G
T T T T B B F
S S S

E I I I I I I
G N N N N N N
F T T T T T T
S

Cables

Rack Wiring

All cables are laid on the rear of rack.


Cables can be laid upwards and downwards to agree with the
installation mode of the rack.

Cable Connection

Fabric plane fiber

Base plane GE

Connect the 1GE ethernet cable between EGBSs in different shelves.

Clock cable

Connect the 10G fiber between EGFSs in different shelves.

Connect the RJ45 clock distribution cable between EGFSs in different


shelves.
The EGFSs in master shelf connect the outside clock reference

485 monitoring cable:

Connect the 485 monitoring cable form PDU (Power Distribution Unit )
at the rack top to the EGBS panel interfaces.

Cable Types
Power, fan, environment
monitoring

E1/T1
Fiber (ethernet,
SDH)
Ethernent

10G fiber

Clock distribution
Outside clock
reference MHz
Bps Line GP
S

GE

Contents

General Introduction
System Architecture
Hardware Description
Product Highlights

Huge Capacity in One Rack


GSM Single Mode Capacity

GU Dual-Mode Capacity (Typical


Value GSM+UMTS)

Traffic
73,500Erl

Traffic
26,800Erl+90,000Erl

BHCA

BHCA
8,400k+17,400k

MCS9 PDTCH
TRX

Throughput 0.87
Gbps+16Gbps
Cell

2,240+4,500

ZXUR 9000

IP-based switch platform,


data transmission with high
efficiency.
High integrity design, realize
huge capacity, facilitate
expansion and evolving data
processing capability.

16,800k
42,800
12,250

UMTS Single Mode Capacity


Traffic

234,000Erl

BHCA

29,000k

Throughput

41.6Gbps

Node B

2800

Cell

5600

Rich Interface Types for Various Networking


Requirements
2G&3G share
2G&3G share
O&M unit

IP interface
unit

ATM interface
unit for 3G

TDM interface
unit for 2G

2G&3G share
switch unit

Based on Unified Platform, Flexible Dual Mode


Resource Sharing and System Processing

ZXUR 9000 Summary


Huge capacity, high integrity,
easy to expand, effectively
saving footprint; adapt to
various environment and fast
growth of traffic load,
protecting operators
investment.

ZXUR 9000

The entire system adopts


redundancy design by platform
and high reliability. No single
point fault, online software
download supported, loading
and being activated in remote.

Abundant interfaces, flexible


networking, TDM/ATM/IP
protocol stack and diverse
physical interfaces like E1, STM1, channelized STM-1, FE and GE
supported, flexibly responding
to transmission changes.

Complete transmission and


processing resources sharing
between GSM and UMTS, unified
RRM realizing users flexible
access to Gu network, balancing
loads, maximally utilizing network
resources. Smooth evolution from
2G to 3G by software upgrading.

All-IP structure meets the


requirement of network evolution.
Compared with TDM/ATM platform,
IP switch management features
convenient maintenance, simple
configuration, flexible expansion,
higher delivery efficiency and more
flexible delivery mechanism.

Simple configuration,
convenient maintenance. Few
board types, including
processing, interface and
switching boards, making
configuration simpler and
expansion easier, also reducing
spare parts types, cutting
down maintenance cost.

Das könnte Ihnen auch gefallen