Sie sind auf Seite 1von 4

HP Array Configuration Utility CLI 8.60-8.

0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console.
=> ctrl all show config
Smart Array P410i in Slot 0 (Embedded)

(sn: 50014380095E36E0)

array A (SAS, Unused Space: 0 MB)


logicaldrive 1 (1.1 TB, RAID 1+0, Recovering, 0% complete)
physicaldrive
physicaldrive
physicaldrive
physicaldrive
physicaldrive
physicaldrive

1I:1:1
1I:1:2
1I:1:3
1I:1:4
2I:1:5
2I:1:6

(port
(port
(port
(port
(port
(port

1I:box
1I:box
1I:box
1I:box
2I:box
2I:box

1:bay
1:bay
1:bay
1:bay
1:bay
1:bay

1,
2,
3,
4,
5,
6,

SAS,
SAS,
SAS,
SAS,
SAS,
SAS,

300
300
300
300
300
300

GB,
GB,
GB,
GB,
GB,
GB,

OK)
OK)
OK)
Rebuilding)
OK)
Predictive Failure

)
physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 300 GB, OK)
physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 300 GB, OK)
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 50014380095E36EF)
=> ctrl all show config detail
Smart Array P410i in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: 50014380095E36E0
Cache Serial Number: PACCQID1031087Q
RAID 6 (ADG) Status: Disabled
Controller Status: OK
Chassis Slot:
Hardware Revision: Rev C
Firmware Version: 3.00
Rebuild Priority: Medium
Expand Priority: Low
Surface Scan Delay: 3 secs
Surface Scan Mode: Idle
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 15 secs
Cache Board Present: True
Cache Status: OK
Accelerator Ratio: 100% Read / 0% Write
Drive Write Cache: Disabled
Total Cache Size: 256 MB
No-Battery Write Cache: Disabled
Battery/Capacitor Count: 0
SATA NCQ Supported: True
Array: A

Interface Type: SAS


Unused Space: 0 MB
Status: OK

Logical Drive: 1
Size: 1.1 TB
Fault Tolerance: RAID 1+0
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 256 KB
Status: Recovering, 0% complete
Array Accelerator: Enabled
Unique Identifier: 600508B1001030393545333645300600
Disk Name: \\.\PhysicalDrive0
Mount Points: C:\ 293.0 GB, D:\ 824.5 GB
Logical Drive Label: AE12751850014380095E36E014D3
Mirror Group 0:
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300
Mirror Group 1:
physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300
physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300
ailure)
physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 300
physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 300
physicaldrive 1I:1:1
Port: 1I
Box: 1
Bay: 1
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD9
Serial Number: D001PAA0DKK21041
Model: HP
EG0300FARTT
PHY Count: 2
PHY Transfer Rate: 6.0GBPS, Unknown
physicaldrive 1I:1:2
Port: 1I
Box: 1
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD9
Serial Number: D001PAA0DKSB1041
Model: HP
EG0300FARTT
PHY Count: 2
PHY Transfer Rate: 6.0GBPS, Unknown

GB,
GB,
GB,
GB,

OK)
OK)
OK)
Rebuilding)

GB, OK)
GB, Predictive F
GB, OK)
GB, OK)

physicaldrive 1I:1:3
Port: 1I
Box: 1
Bay: 3
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD9
Serial Number: D001PAA0DJL51041
Model: HP
EG0300FARTT
PHY Count: 2
PHY Transfer Rate: 6.0GBPS, Unknown
physicaldrive 1I:1:4
Port: 1I
Box: 1
Bay: 4
Status: Rebuilding
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD9
Serial Number: D001PAA0DJYR1041
Model: HP
EG0300FARTT
PHY Count: 2
PHY Transfer Rate: 6.0GBPS, Unknown
physicaldrive 2I:1:5
Port: 2I
Box: 1
Bay: 5
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD8
Serial Number:
PFV6N5KE
Model: HP
DG0300FARVV
PHY Count: 2
PHY Transfer Rate: 6.0GBPS, Unknown
physicaldrive 2I:1:6
Port: 2I
Box: 1
Bay: 6
Status: Predictive Failure
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD9
Serial Number: D001PAA0DJJC1041
Model: HP
EG0300FARTT
PHY Count: 2
PHY Transfer Rate: 6.0GBPS, Unknown

physicaldrive 2I:1:7
Port: 2I
Box: 1
Bay: 7
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD9
Serial Number: D001PAA0DKLE1041
Model: HP
EG0300FARTT
PHY Count: 2
PHY Transfer Rate: 6.0GBPS, Unknown
physicaldrive 2I:1:8
Port: 2I
Box: 1
Bay: 8
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD9
Serial Number: D001PAA0DKFU1041
Model: HP
EG0300FARTT
PHY Count: 2
PHY Transfer Rate: 6.0GBPS, Unknown
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250
Device Number: 250
Firmware Version: RevC
WWID: 50014380095E36EF
Vendor ID: PMCSIERA
Model: SRC 8x6G

Das könnte Ihnen auch gefallen