Sie sind auf Seite 1von 1

2nd Level

Construction Joints (8/04/15)


1

X1

2
25'-6"

27'-0"

27'-0"

27'-0"

27'-0"

27'-0"

27'-0"

10

27'-0"

11

27'-0"

12

27'-0"

T6

13

27'-0"

27'-0"

14

15

27'-0"

16

27'-0"

18'-3"

T5
4
A4.0
1

T4
TA

A3.08

A3.08

A3.09

T3
5

T2
A4.12

A4.12
EWA - 2 A

N
OVE

EWA - 2 A

2
A4.0

A4.12

Tower Pour #3

METAL LOCKERS

Parking Pour #3
STORAGE
230

BIKE RACK

Parking Pour #2

CONFERENCE
ROOM
223

PARKING

FLOOR DRAIN

227

UP TO LEVEL 03

9'-11"

DOWN TO LEVEL 01-M

9'-2"

9'-11"

8'-6"

9'-2"

8'-0"

05 1516

60'-0"

22 1000

TC

VEHICLE BARRIER
CABLE GUARDS

ASST OFF
221

ASST OFF
222

EQ

DN

05 5100

2'-5"

BOLLARDS

STEEL GUARDRAIL

UP
11'-2

5'-9"

3/4"

15'-7"

ELEVATOR LOBBY
252
1'-10"

Tower Pour #1

1
A4.12

PARKING
227

54'-0"

A3.12

1
A2.02A

0
A4.0
5

Parking Pour #1

BOLLARDS

05 5219

MENS CHANGING
RM
216

HOUSEKEEPING
226

21

5
A4.0
2

17'-0 1/2"

SHEET METAL BLANK OFF PANEL

MENS
217

STORAGE
231

FLOOR DRAIN

22 1000

A4.41

A4.21

A3.06

OPEN OFFICE
220

WOMENS
CHANGING RM
WOMENS
214
215

8'-9"

DN

/4"
8'-8 1

/4"

3/4"

/2"

21
05 5219

UP

STAIR 1
261

SERVICE LOBBY
251

7'-4 3

Q EQ
EQ E
Q
EQ E

10'-7

4'-5 1

8'-0"

10'-3"

1'-0"

5'-0"

STAIR 2
262

1/2"
13'-1

Tower Pour #2

TD

MNGR OFF
224

21

A4.05

10 5600

21

5
A4.0
1

REF

10 5113

TB

SEE A2.08 FOR


RESIDENCE A
TYPICAL
INFORMATION

H
DIS

T1

RESIDENCE ASTACK B
2A

E
WIN
E
R F

A4.12

A3.07

A3.08

A4.02

8
SIM

0
A4.0
1

A4.41

5
A4.13

A4.11
6

FLOOR DRAIN

22 1000

22 1000

ELEV RM
244
GARAGE
314G

GARAGE
236

GARAGE
313G

GARAGE
237

Townhomes Pour #3.B


D

TECH RM
243

6
GARAGE
234

A4.13

GARAGE
309G

GARAGE
233

GARAGE
310G

STORAGE
242

Townhomes Pour #3.A


D

STORAGE
232

GARAGE
308G

21
UP

DISH

DN

OVEN

VESTIBULE
247

GARAGE
307G

1
A4.10
14'-8"

Townhomes Pour #2

Townhomes Pour #1

OVEN

REF

WINE
REF

DISH

REF

REF

REF

REF

A4.02

GARAGE
235

REF

GARAGE
238

GARAGE
315G

TRASH
241

IT ROOM
258

A4.02

A4.11

GARAGE
316G

A4.14

WINE
REF

CONFERENCE
ROOM CONFERENCE
ROOM
229
228

25'-0"

UP

CONFERENCE
ROOM
246

C
D

9'-0"

ELEV. 6

STAIR 3
263

A4.00

STAIR 4
264

A4.14

ELEC
260
6

DN

A4.14

FLOOR DRAIN

PODIUM ELEV
LOBBY
240

IT ROOM
239

21

6'-9"

264

A4.00

239

3'-6"

240

11'-0 1/2"

ELEV. 7

STAIR VESTIBULE
245

PODIUM 1BR
200

245

A4.02

A4.11

G
4

A4.10

3
A4.11

1
A2.02D

PODIUM STUDIO A PODIUM STUDIO B


212
211

PODIUM
TOWNHOME
310

PODIUM
TOWNHOME
308

PODIUM
TOWNHOME
309

PODIUM
TOWNHOME
307

1
A2.02C

A4.13

PODIUM
TOWNHOME
306

PODIUM
TOWNHOME
313

A4.01

A3.11

9'

PODIUM
TOWNHOME
314

PODIUM
TOWNHOME
315

A4.01

PODIUM
TOWNHOME
316

PODIUM
TOWNHOME
305

PODIUM
TOWNHOME
304

PODIUM STUDIO A
203

A4.11

A4.11

A4.10

A4.10

A4.10

PODIUM STUDIO B
202

A4.00

A4.02

A4.02

A4.14

MEP

16'-6"

E-ALUM-07, LOUVERS

A4.00

08 4400

A4.50

PODIUM 2BR
201

1
A2.02B

Level 02
3/32" = 1'-0"

PLAN GENERAL NOTES:


MATERIAL LEGEND
CONCRETE

1.
2.

CMU

3.

FRAMED WALLS

4.

PC

PIPE CHASE

TC

TRASH CHUTE

DC

DUCT CHASE

5.
6.
7.
8.
9.
10.
11.

Refer to sheet A0.00 for general notes, symbols, legends and alternates
Refer to L series for scope of work, dimensions and layout of site beyond the
outside face of exterior wall
Refer to enlarged floor plans for dimensions, door symbols and other references
not covered at this scale
Refer to A0.02 for typical bath fixture placement and shower sizes, conform to
these standards unless noted otherwise.
Refer to A5 series for enlarged stair, elevator, and trash chute plans and sections
Refer to A6.4 series for kitchen elevations, sections and enlarged plans
Refer to A8.0 series for partition types
Refer to A8.2 series for door and window schedules
Refer to A8.4 series for finish schedule and A6.0 for finish plans and elevations
Finish floor Elevation Equal + 8'6" above sea level
Refer to A6.90 Series for information about Casework Wardrobes, W.I.C.'s, and
Sliding Closet Doors

TMK: 514814

Bldg. Code

Elec. Code

Mech Code

ZPRB (Land Use Ordinance)

LEVEL 02 PLAN

AUAHI TOWER

PALEKANA PERMITS
THIRD PARTY CERTIFICATION

Scale:
As indicated
Drawn By:
Author

1108 Auahi Street

Project Number:

Structural (Non-Single/2-Family Dwellings)


21
NO.

04/17/2015 Bulletin #06.1


DATE
DESCRIPTION

Honolulu, HI 96814
2014 Solomon Cordwell Buenz

EXPIRATION:
APRIL 30, 2016

2012020

Sheet Number:

A2.02