Sie sind auf Seite 1von 23

B

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

Table of Content
Row

Part of

Designation

Comment

Title line 1

Title line 2

Title line 3

Revision

P98014-D-E-SC-013

AA1

COVER SHEET

13.8kV CONTROL PANEL 2

(=K00+W2)

SCHEMATIC DIAGRAM

A1

P98014-D-E-SC-013

AB1

TABLE OF CONTENTS

13.8kV CONTROL PANEL 2

LIST DOCUMENTS

P98014-D-E-SC-013

B1

GENERAL OVERVIEW

13.8kV CONTROL PANEL 2

GENERAL EXPLANATION

P98014-D-E-SC-013

C1

OVERVIEW DIAGRAM

13.8kV CONTROL PANEL 2

FRONT VIEW AND SECTION

A1

P98014-D-E-SC-013

D1

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

AC SUPPLY DISTRIBUTION

A1

P98014-D-E-SC-013

E1

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

DC SUPPLY DISTRIBUTION

A1

P98014-D-E-SC-013

M1

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

GENERAL SIGNALLING

A1

P98014-D-E-SC-013

M2

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

GENERAL SIGNALLING

A1

P98014-D-E-SC-013

M3

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

LOCAL REMOTE STATUS MULTIPLICATION

A1

10

P98014-D-E-SC-013

M4

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 1

GENERAL SIGNALLING

A1

11

P98014-D-E-SC-013

M5

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

SIGNALLING TO BCU COMMON PANEL

A1

12

P98014-D-E-SC-013

M6

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

SIGNALLING TO BCU COMMON PANEL

A1

13

P98014-D-E-SC-013

M7

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

SIGNALLING TO TSEA PANEL

A1

14

P98014-D-E-SC-013

M8

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

EXTERNAL SIGNAL

A1

15

P98014-D-E-SC-013

N1

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

VCB 13.8kV CONTROL

A1

16

P98014-D-E-SC-013

N2

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

VCB 13.8kV CONTROL

A1

17

P98014-D-E-SC-013

N3

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

VCB 13.8kV CONTROL

A1

18

P98014-D-E-SC-013

N4

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

MV EQUIPMENT CHECK BACK INDICATION

A1

19

P98014-D-E-SC-013

N5

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

MV EQUIPMENT CHECK BACK INDICATION

A1

20

P98014-D-E-SC-013

N6

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

MV EQUIPMENT CHECK BACK INDICATION

A1

21

P98014-D-E-SC-013

R1

CIRCUIT DIAGRAM

13.8kV CONTROL PANEL 2

AC/DC SUPPLY FAILURE INDICATION

A1

22

P98014-D-E-SC-013

Z1

COMPONENT LIST

13.8kV CONTROL PANEL 2

AUXILIARY EQUIPMENTS

A1

23

P98014-D-E-SC-013

Z2

COMPONENT LIST

13.8kV CONTROL PANEL 2

AUXILIARY EQUIPMENTS

A1

A1
Title line 3

A1

Created with

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Customer Order No

: JO400003626

13.8kV CONTROL PANEL 2


LIST DOCUMENTS

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

TABLE OF CONTENTS

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

AB1

B1

Created with

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

PROTECTION FUNCTIONS

COMPONENT IDENTIFICATION

14

Locked rotor protection

-A

Bay control unit (I/O)

21

Distance protection, phase

-B

Electrical control mech. CB & DS

21N

Distance protection, earth (ground)

21FL

Fault locator

-C

Capacitor

24

Overfluxing (V/f protection)

-D

Computer

25

Synchronizing, shyncronism check

-E

Indoor / outdoor lighting, fan

27

Undervoltage

-F

Protection relay

27/34

Stator earth fault 3rd harmonic

-G

Generator

32

Directional power

-H

Indicator (visual alarm)

32F

Forward power

32R

Reverse power

TRANSFORMER

FUSE AND ARRESTER

TERMINAL
Terminal general

Current transformer

Normally open (NO) contact

Fuse general

Plug in connector

Pressure switch and sensors


Socket
Transformer with 2 winding
Normally close (NC) contact

Terminal accessories for terminal list


Cover
Insulation plate
High level insulation plate

Change over contact

Test socket

Lightning arrester

Slide bridge

Contactor & general coil relay


Autotransformer with 3
winding

Undercurrent or underpower

-L

Inductance

40

Loss of field

-M

Motor

46

Load unbalance, negative phase sequence overcurrent

-N

Automatic voltage regulator

47

Phase sequence voltage

-P

Metering

Motor starting protection

-Q

HV equipment / apparatus

49

Thermal overload

-R

Resistor

49R

Rotor thermal protection

-S

Test plug

49S

Stator thermal protection

-T

CT and VT

50

Instantaneous overcurrent

-U

Transducer

50N

Instantaneous earth fault overcurrent

-V

Varistor

50BF

Breaker failure

-X

Test block w/ additional

51GN

Zero speed and underspeed device

51

Overcurrent time relay, phase

51N

Overcurrent time relay, earth

51V
59

Star circuit

Lamp general

Star circuit with neutral


connection

Drop annunciator
Circuit breaker

Delta circuit

Overcurrent time relay, voltage controlled

Ammeter

Resistor variable

Overvoltage

Frequency meter

59GN

Stator earth fault protection

Syn

Synchronoscope

64

100% Stator earth fault protection (20Hz)

Voltmeter

64R

Rotor earth fault

VV

Double voltmeter

67

Directional overcurrent

Var

Var meter

67N

Directional earth fault overcurrent

VarH

Var hour meter

67G

Stator earth fault directional overcurrent

Watt meter

68

Power swing detection

74TC

Trip circuit supervision

78

Out of step protection

79

Auto reclose

81

Frequency protection

L1,..L3 AC infeed

81R

Rate of frequency change protection, vector jump supervision

N, PE

85

Carrier interface / remote trip

1L+

Horn

COMPONENT SEMICONDUCTOR
Resistor

Double frequency meter

Isolating switch
(disconnector)

Zigzag circuit

Make before break contact

FF

Semaphore indicator

Open delta circuit


1 pulse close + 1 pulse open
contact

ABBREVIATIONS

Residual voltage earth fault protection

SWITCHES

Off delay contact

Suffix (A or V)

59N

Slide bar
LAMP AND INDICATION

On delay contact

48

WH

Plug

Fuse isolating switch

Buzzer, bell, horn


-K

Fuse top, with input fuse

Transformer with 3 winding

37

Double-way isolator switch


(disconnector)

GROUNDING

Earth general

Double-way isolator with


earth

Ground, chassis
Contactor general

Dioda
Load break switch
Protective earth

Capacitor
Contactor coil ON-delay
(operating delay)

Contactor coil OFF-delay


(releasing delay)

Resistor volt sensitive,


varistor

POWER SUPPLY AND CONVERTER

Switch with operation


*)

MINIATUR CIRCUIT BREAKER


Hand control general
Power supply general

Watt hour meter

Operation by push

MCB 1 pole in general

Operation by turning

Contactor accessories

I>

POTENTIAL DESIGNATION

*)
Emergency switch
DC power supply

Suppressor dioda for


contactor coil

U<

Trip low voltage

I>>

Trip instantaneous
overcurrent

protection

Lockout function

87G

Differential protection generator

2L+

DC infeed for CB control 1

87T

Differential protection transformer

3L+

DC infeed for CB control 2

87BB

Differential protection busbar

4L+

DC infeed for control/signal

87M

Differential protection motor

87L

Differential protection line

5L+

DC infeed for HV Equipment

87N

Restricted earth fault protection

94

Tripping relay

97S

Bucholz relay (Oil surge)

97OLTC

OLTC protection relay

df / dt

Rate of frequency

I>

RC element for contactor coil

I>>

BW+

Operation by key
Reactive power converter

I>

Varistor for contactor coil

DC infeed for bus wire

I>>

I>

Operation by motor

Trip over current,


instantaneous overcurrent
Inverter power converter

I>>

control

Operation by roller

*) Protection

DC infeed for main & back up

86

Power operated mechanism


general

Trip thermal, time overcurrent


Trip thermal, time
overcurrent, instantaneous
overcurrent
Trip overcurrent, thermal,
time

Latch mechanism + motor


drive

Mechanical interlock

General converter

Noth locked
Noth after automatic return
Bridge connected rectifier
circuit

Lock-out, latched
Lock-out, not latched

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

CONTACT AND CONTACTORS

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


GENERAL EXPLANATION
Title line 3
PT. SCHNEIDER INDONESIA

Format

A3

NTS

Drawn By

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

GENERAL OVERVIEW

Scale

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

B1

C1

FRONT VIEW

REAR VIEW
LEGEND :
A

2200
PANEL NAME PLATE

2100
2000

No.

Device

1.
2.
3.

-S401
-H84..6, -H94.5
-52G4..6
-52TIE-4/5

Description

Type

"Remote / Supervisory" selector switch c/w key


Semaphore for Earthing Switch Indicator
Discrepancy Switch for CB

XB5
SPS
BHL3

Brand

Qty.

Schneider / eq.
Fuji / equal
Fuji / equal

1 pc
6 pcs
7 pcs

-52TIE-5/6

1900

-52TX1..2

1800
B

1700
MODE CONTROL
SWITCH

1600

REM

SUP

-S401

1500

-HG4

-HG5

1400

-HG6

1300
-H84

-H85

SECTION A-A

-H86

1200
-52G4

1100

-52G5

-52G6

65

670

65
65

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

1000
-52TIE-4/5

-52TIE-5/6

900
-52TX-2

800

-52TX-1

D
-H95

800
600

-H94

670

700
600

gland plate

500
cu 5x30x500

400

65

300
E

800

100

Created with

PANEL CHARACTERISTIC

BASE FRAME

0
Y

180

200

100

200

300

400

500

600

700

800

100

200

300

400

500

600

700

800

Type

: Free Standing Panel

Thickness

: 2mm

Dimension

: 2200 x 800 x 800 (HxWxD)

Protection Degree

: IP42

Painted

: RAL 7032

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


FRONT VIEW AND SECTION

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

OVERVIEW DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

C1

D1

=K00+W2

CUBICLE

CUBICLE

13.8kV CONTROL PANEL 2

LIGHTING

HEATING

SOCKET

AC POWER SUPPLY
-XAC 1

230VAC, 60Hz

-XAC 2

-F100
/Z2.6A
10A

I>

11

-B101
/Z1.1E

12

-S101
/Z1.2E

-R101

AC DISTRIBUTION BOARD
=NE1+NE1

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

/Z1.4E

-H101

Ph

-X101

/Z1.3E

/Z1.4E

PE

E
PE

-XAC 3

-XAC 4

Created with

PE1

PE2

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


AC SUPPLY DISTRIBUTION

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

D1

E1

=K00+W2

POWER SUPPLY
CONTROL PROTECTION

13.8kV CONTROL PANEL 2

CIRCUIT

A
DC POWER SUPPLY

-XDC 1

-XDC 2

=NK1+NK1
110VDC MAIN DISTRIBUTION BOARD

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

-F201

D
I>
1

/Z2.4A
10A

I>
3

1L/M1.1F

/M1.1A

1L+

Created with

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


DC SUPPLY DISTRIBUTION

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

E1

M1

VCB INCOMING 4

VCB INCOMING 5

VCB INCOMING 6

VCB BUS SECTION 5

VCB OUTGOING TX-2

=K00+W2
VCB BUS SECTION 4

13.8kV CONTROL PANEL 2


OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

A
/E1.3F

1L+

1L+

-X100 1

/M2.1A

-X5 76

-X5 70

-X5 90

-X5 68

-X5 90

-X5 68

-X5 76

-X5 70

OUTGOING TX-2 PANEL


13.8kV SIDE

-X5 70

BUS TIE 5 PANEL


13.8kV SIDE

-X5 76

BUS TIE 4 PANEL


13.8kV SIDE

-X5 70

INCOMING 6 PANEL
13.8kV SIDE

-X5 76

INCOMING 5 PANEL
13.8kV SIDE

INCOMING 4 PANEL
13.8kV SIDE

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

-X5 77

-X5 71

-X5 77

-X5 71

-X5 77

-X5 71

-X5 91

-X5 69

-X5 91

-X5 69

-X5 78

-X5 71

-X100 23

24

-X100 25

26

-X100 27

28

-X100 29

30

-X100 31

32

-X100 33

34

A1

A1

-KJ12
/Z1.7E

A2

A1

A2

A1

-KJ10
/Z1.7D

A2

A1

-KJ11
/Z1.7D

A2

A1

-KJ08
/Z1.7D

A2

A1

-KJ09
/Z1.7D

A2

A1

-KJ06
/Z1.7D

A2

A1

-KJ07
/Z1.7D

A2

A1

A2

A1

-KJ04
/Z1.7C

A2

-KJ02
/Z1.7C

-KJ05
/Z1.7C

A2

-KJ03
/Z1.7C

A2

-KJ01
/Z1.7C

A1

MT-

Created with

-X100 19

/E1.3F

/M2.1E

20

1L-

1L-

/N4.1F

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


GENERAL SIGNALLING

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

M1

M2

=K00+W2
VCB OUTGOING TX-1

GENERATOR 4 RUN

GENERATOR 5 RUN

GENERATOR 6 RUN

13.8kV CONTROL PANEL 2


OPEN

CLOSE

A
/M1.8A

1L+

1L+

-X100 8

/M3.1A

-X5 78

-X5 71

-X100 35

36

37

38

39

-X300 2

40

INCOMING 6 PANEL
13.8kV SIDE
-X300 5

-KGR3
/Z1.5B

-X300 4

A1

-KGR2
/Z1.5B

A2

-KGR1
/Z1.5A

-X300 3

A1

-X300 1

A2

-X5 70

A1

-X5 76

INCOMING 5 PANEL
13.8kV SIDE

INCOMING 4 PANEL
13.8kV SIDE

A2

OUTGOING TX-1 PANEL


13.8kV SIDE

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

-X300 6

INCOMING 6 PANEL
13.8kV SIDE

INCOMING 5 PANEL
13.8kV SIDE

INCOMING 4 PANEL
13.8kV SIDE

MT-

MT-

/M3.1E
/M4.1E

Created with

/M1.8E

A1

-KJ14
/Z1.7E

A2

A2

-KJ13
/Z1.7E

A1

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


GENERAL SIGNALLING

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

M2

M3

=K00+W2

SEL. SWITCH

SEL. SWITCH

IN MIMIC

IN BCU

POSITION

POSITION

13.8kV CONTROL PANEL 2

PILOT LAMP

PILOT LAMP

PILOT LAMP

GENERATOR 4 RUN

GENERATOR 5 RUN

GENERATOR 6 RUN

A
/M2.8A

1L+

1L+

/M4.1A

-X100 10

BCU

-S401
/Z1.1D

-KGR3

/Z1.5B

/Z1.5B

14

12

-KGR2

/Z1.6A

11

-KGR1

11

14

12

14

12

/Z1.2D

11

MIMIC

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

-HG6
/Z2.3D

MT-

Created with

/M2.8E

-HG5
/Z2.3D
1

-HG4
/Z2.3C
1

A1

-KBC4
/Z1.7C

A2

A1

-KBC3
/Z1.7B

A2

-KBC2
/Z1.7B

A1

A1

-KBC1
/Z1.7B

A2

/Z1.7B

A1

-KMC4

A2

/Z1.7B

A1

-KMC3

A2

/Z1.7B

A2

A1

-KMC2

A2

/Z1.7A

A2

-KMC1

A1

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


LOCAL REMOTE STATUS MULTIPLICATION

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

M3

M4

=K00+W2
13.8kV CONTROL PANEL 2

EARTHING SWITCH

EARTHING SWITCH

EARTHING SWITCH

EARTHING SWITCH

INCOMING 4

INCOMING 5

INCOMING 6

OUTGOING TX-2

OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

OPEN

EARTHING SWITCH
OUTGOING TX-1

CLOSE

OPEN

CLOSE

A
/M3.8A

1L+

1L+

-X100 13

14

15

16

17

/N4.1A

18

-X5 46

-X5 48

-X5 46

-X5 48

-X5 46

-X5 48

-X5 46

OUTGOING TX-1 PANEL


13.8kV SIDE

-X5 48

OUTGOING TX-2 PANEL


13.8kV SIDE

-X5 46

INCOMING 6 PANEL
13.8kV SIDE

-X5 48

INCOMING 5 PANEL
13.8kV SIDE

INCOMING 4 PANEL
13.8kV SIDE

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

-X5 49

-X5 47

-X5 49

-X5 47

-X5 49

-X5 47

-X5 49

-X5 47

-X5 49

-X5 47

-X100 41

42

-X100 43

44

-X100 45

46

-X100 47

48

-X100 49

50

/Z1.5D

A1

A1
-KSW10

A2

/Z1.5D

A1

-KSW8

A2

A1

/Z1.5D

A2

A1
/Z1.5C

A1

A1

-KSW6

-KSW9

A2

/Z1.5C

/Z1.5C

A2

A1
-KSW4

-KSW7

MT-

Created with

/M2.8E

/Z1.5C

A2

/Z1.5C

-KSW5

A2

-KSW2

A1

/Z1.5C

A2

-KSW3

A2

/Z1.5B

A2

-KSW1

A1

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 1


GENERAL SIGNALLING

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

M4

M5

=K00+W2
VCB INCOMING 4

13.8kV CONTROL PANEL 2

OPEN

VCB INCOMING 5

CLOSE

OPEN

VCB INCOMING 6

CLOSE

OPEN

VCB BUS SECTION 4

CLOSE

OPEN

VCB BUS SECTION 5

CLOSE

OPEN

VCB OUTGOING TX-2

CLOSE

OPEN

VCB OUTGOING TX-1

CLOSE

OPEN

CLOSE

=E00+X2
COMMON PANEL

-X400 3

-X900 1

-KJ14
/Z1.7E

24

22

-KJ13
/Z1.7E

21

-KJ12
/Z1.7E

21

-KJ11
/Z1.7D

21

-KJ10
/Z1.7D

21

-KJ09
/Z1.7D

21

-KJ08
/Z1.7D

21

-KJ07
/Z1.7D

21

-KJ06
/Z1.7D

21

-KJ05
/Z1.7C

21

-KJ04
/Z1.7C

21

-KJ03
/Z1.7C

21

-KJ02
/Z1.7C

21

-KJ01
/Z1.7C

21

24

22

24

22

24

22

24

22

24

22

24

22

24

22

24

22

24

22

24

22

24

22

24

22

24

22

21

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

-X900 2

-X400 59

-X400 60

-X400 61

-X400 62

-X400 63

-X400 64

-X400 65

-X400 66

10

11

12

13

14

15

-X400 67

-X400 68

-X400 69

-X400 70

-X400 71

-X400 72

16

17

18

Created with

=E00+X2
COMMON PANEL

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


SIGNALLING TO BCU COMMON PANEL

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

M5

M6

=K00+W2
13.8kV CONTROL PANEL 2

EARTHING SWITCH

EARTHING SWITCH

EARTHING SWITCH

EARTHING SWITCH

INCOMING 4

INCOMING 5

INCOMING 6

OUTGOING TX-2

OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

OPEN

EARTHING SWITCH
OUTGOING TX-1

CLOSE

OPEN

CLOSE

=E00+X2
COMMON PANEL

-X400 8

-X904 1

-KSW10

/Z1.6D

/Z1.6D

24

22

-KSW9

/Z1.6D

21

-KSW8

/Z1.6C

21

-KSW7

/Z1.6C

21

-KSW6

/Z1.6C

21

-KSW5

/Z1.6C

21

-KSW4

/Z1.6C

21

-KSW3

/Z1.6C

21

-KSW2

/Z1.6B

21

-KSW1

21

24

22

24

22

24

22

24

22

24

22

24

22

24

22

24

22

24

22

21

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

-X904 2

-X400 85

-X400 87

-X400 88

-X400 89

-X400 90

-X400 91

-X400 92

10

11

-X400 93

-X400 94

12

Created with

=E00+X2
COMMON PANEL

-X400 86

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


SIGNALLING TO BCU COMMON PANEL

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

M6

M7

=K00+W2
VCB INCOMING 4

13.8kV CONTROL PANEL 2

OPEN

VCB INCOMING 5

CLOSE

OPEN

VCB INCOMING 6

CLOSE

OPEN

VCB BUS SECTION 4

CLOSE

OPEN

VCB BUS SECTION 5

CLOSE

OPEN

VCB OUTGOING TX-2

CLOSE

OPEN

VCB OUTGOING TX-1

CLOSE

OPEN

CLOSE

TSEA PANEL
(OUT OF SCOPE)

-X902 1

-KJ14
/Z1.8E

34

32

-KJ13
/Z1.8E

31

-KJ12
/Z1.8E

31

-KJ11
/Z1.8D

31

-KJ10
/Z1.8D

31

-KJ09
/Z1.8D

31

-KJ08
/Z1.8D

31

-KJ07
/Z1.8D

31

-KJ06
/Z1.8D

31

-KJ05
/Z1.8C

31

-KJ04
/Z1.8C

31

-KJ03
/Z1.8C

31

-KJ02
/Z1.8C

31

-KJ01
/Z1.8C

31

34

32

34

32

34

32

34

32

34

32

34

32

34

32

34

32

34

32

34

32

34

32

34

32

34

32

31

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

-X902 2

10

11

12

13

14

15

16

17

18

Created with

TSEA PANEL
(OUT OF SCOPE)

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


SIGNALLING TO TSEA PANEL

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

M7

M8

=K00+W2

VCB OUTGOING TX-01

VCB OUTGOING TX-02

OPEN =E01+WR1

OPEN =E02+WR1

13.8kV CONTROL PANEL 2

=E02+WR1
CRP

=E01+WR1
CRP

-X903 1

-X903 1

-X903 1

-X903 3

-KJ11
/Z1.8D

44

42

-KJ13
/Z1.8E

41

44

42

41

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

-X903 2

-X903 4

-X903 2

-X903 2

E
=E02+WR1
CRP

Created with

=E01+WR1
CRP

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


EXTERNAL SIGNAL

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

M8

N1

=K00+W2

VCB INCOMING 4

VCB INCOMING 5

VCB INCOMING 6

13.8kV CONTROL PANEL 2


OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

-X5 1

-X5 3

INCOMING 6 PANEL
13.8kV SIDE

-X5 3

INCOMING 5 PANEL
13.8kV SIDE

INCOMING 4 PANEL
13.8kV SIDE

-X5 1

-X5 3

-X5 1

59

-X100 34

60

-X100 29

-X200 3

-X100 32

30

-X200 9

4
-X200 5

-X100 35

33

-X200 15

10
-X200 11

/Z1.2B
8

-SG6
/Z1.2B

/Z1.2B
8

-SG5
/Z1.2B

=E00+X2
COMMON PANEL

-X100 31

58

-X100 28

OFF-PUSH
OFF
ON
ON-PUSH

-X200 52

=E00+X2
COMMON PANEL

-X200 45

-X200 51

-X200 44

-X200 50

OFF-PUSH
OFF
ON
ON-PUSH

7
/Z1.2A

-X200 43

=E00+X2
COMMON PANEL

/Z1.2A

24

22
/Z1.7B

31

-KBC3

/Z1.8B

21

-KBC1

/Z1.7B

31

-KMC3

/Z1.8A

11

-KMC1

/Z1.7B

21

-KBC3

/Z1.7B

11

-KBC1

/Z1.7B

21

-KMC3

/Z1.8A

41

-KMC1

/Z1.8B

11

-KBC2

/Z1.7B

41

-KBC1

/Z1.8B

11

-KMC2

/Z1.7A

21

34

32

24

22

14

34

32

14

12

24

22

14

12

24

22

44

42

14

12

44

42

-X200 13

-KMC1

-SG4

-X200 7

14

12

-X200 1

OFF-PUSH
OFF
ON
ON-PUSH

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

16
-X200 17

12

36

18

Created with

-X5 2

-X5 4

-X5 2

INCOMING 6 PANEL
13.8kV SIDE

-X5 4
INCOMING 5 PANEL
13.8kV SIDE

-X5 2

INCOMING 4 PANEL
13.8kV SIDE

-X5 4

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


VCB 13.8kV CONTROL

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

N1

N2

=K00+W2

VCB BUS SECTION 4

VCB BUS SECTION 6

VCB OUTGOING TX-2

13.8kV CONTROL PANEL 2


OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

OPEN

CLOSE

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

COMMAND

OUTGOING TX-2 PANEL


13.8kV SIDE

BUS TIE 5 PANEL


13.8kV SIDE

BUS TIE 4 PANEL


13.8kV SIDE

-X5 3

-X5 1

-X5 3

-X5 1

-X5 3

-X5 1

62

43

63

38

-X200 21

39

41

-X200 27

22
-X200 23

42

44

-X200 33

28
-X200 29

24

/Z1.2B
8

-SQ4
/Z1.2B

/Z1.2B
8

-ST5
/Z1.2B

=E00+X2
COMMON PANEL

40

61

37

OFF-PUSH
OFF
ON
ON-PUSH

-X200 55

=E00+X2
COMMON PANEL

-X200 48

-X200 54

-X200 47

-X200 53

OFF-PUSH
OFF
ON
ON-PUSH

7
/Z1.2B

-X200 46

=E00+X2
COMMON PANEL

/Z1.2B

14

12
/Z1.7C

21

-KBC4

/Z1.7B

11

-KBC2

/Z1.7B

21

-KMC4

/Z1.7B

41

-KMC2

/Z1.8B

11

-KBC3

/Z1.7B

41

-KBC2

/Z1.8B

11

-KMC3

/Z1.7B

31

-KMC2

/Z1.8B

41

-KBC3

/Z1.8B

31

-KBC1

/Z1.8B

41

-KMC3

/Z1.8A

11

24

22

14

12

32

24

22

44

42

14

12

44

42

14

12

34

32

44

42

34

32

-X200 31

26

-KMC1

-ST4

-X200 25

20

44

42

-X200 19

OFF-PUSH
OFF
ON
ON-PUSH

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

34
-X200 35

30

45

36

Created with

-X5 2

-X5 4

-X5 2

OUTGOING TX-2 PANEL


13.8kV SIDE

-X5 4
BUS TIE 5 PANEL
13.8kV SIDE

-X5 2

BUS TIE 4 PANEL


13.8kV SIDE

-X5 4

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


VCB 13.8kV CONTROL

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

N2

N3

=K00+W2

VCB OUTGOING TX-1

13.8kV CONTROL PANEL 2


OPEN

CLOSE

OPEN

CLOSE

COMMAND

COMMAND

COMMAND

COMMAND

OUTGOING TX-1 PANEL


13.8kV SIDE

-X5 3

-X5 1

/Z1.2B

/Z1.2B
6

24

22
/Z1.7C

31

-KBC4

/Z1.8B

21

34

32

24

22

-KBC2

/Z1.7B

21

-KMC4

/Z1.8B

31

-KMC2

-X200 49

-X200 56

46

64

=E00+X2
COMMON PANEL

-SQ5

38

34

32

-X200 37

OFF-PUSH
OFF
ON
ON-PUSH

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

D
47

-X200 39

48

40
-X200 41

42

57

58

E
2

Created with

OUTGOING TX-1 PANEL


13.8kV SIDE

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


VCB 13.8kV CONTROL

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

N3

N4

=K00+W2
VCB INCOMING 4

13.8kV CONTROL PANEL 2

CLOSE

VCB INCOMING 5

OPEN

CLOSE

VCB INCOMING 6

OPEN

CLOSE

VCB BUS SECTION 4

OPEN

CLOSE

VCB BUS SECTION 5

OPEN

CLOSE

VCB OUTGOING TX-2

OPEN

CLOSE

OPEN

A
/M4.8A

1L+

1L+

-X100 11

12

-D09

-D011

/Z2.1C

/Z2.1C

14

12

11
12

-D07
/Z2.1C

-D05
/Z2.1B

-D03
/Z2.1B

-D01

10

12

/Z1.3B

/Z2.2B

OFF-PUSH
OFF
ON
ON-PUSH

OFF-PUSH
OFF
ON
ON-PUSH

11

1
/Z1.3B

/Z1.3B

10

12

-SQ4

/Z1.3B

/Z1.3B

10

12

-ST5

/Z1.3B

/Z1.3B

OFF-PUSH
OFF
ON
ON-PUSH

11

-ST4

/Z1.3B

/Z1.3B
10

OFF-PUSH
OFF
ON
ON-PUSH

11

-SG6

/Z1.3B

/Z1.3A
10

OFF-PUSH
OFF
ON
ON-PUSH

11

-SG5

/Z1.3A

11

-KJ11
/Z1.7D

11

-KJ12
/Z1.7E

11

-KJ09
/Z1.7D

11

-KJ10
/Z1.7D

11

-KJ07
/Z1.7D

11

-KJ08
/Z1.7D

11

-KJ05
/Z1.7C

11

-KJ06
/Z1.7D

11

-KJ03
/Z1.7C

/N5.1A

11

14

12

14

12

14

12

14

12

14

12

14

12

14

12

14

12

14

12

14

12

-KJ04
/Z1.7C

11

-KJ01
/Z1.7C

11

-KJ02
/Z1.7C

12

-SG4

14

12

MT+

OFF-PUSH
OFF
ON
ON-PUSH

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

CBK+

/Z1.5D

18

15

/Z2.1D
A

-D012
K

X2

-SQ4
/Z1.3B
X2

-ST5
/Z1.3B
X2

-ST4
/Z1.3B
X2

-SG6
/Z1.3B
X2

/Z2.1C
A

-D010
K

X1

/Z2.1C
A

X1

-D08
K

X1

/Z2.1C
A

X1

A1

-KFL

-D06
K

X1

/Z2.1B
A

-SG5
/Z1.3B
X2

-D04
K

-SG4
/Z1.3A

A2

-KFL
/Z1.4D

/Z2.1B
A

X1

-D02
K

/N5.1D

CBK-

/N5.1E

16

Created with

-X100 21

/M1.8F

1L-

1L-

/N5.1F

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


MV EQUIPMENT CHECK BACK INDICATION

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

N4

N5

=K00+W2
VCB OUTGOING TX-1

13.8kV CONTROL PANEL 2

CLOSE

OPEN

EARTHING SWITCH

EARTHING SWITCH

INCOMING 1
4

INCOMING 2
5

OPEN

CLOSE

OPEN

EARTHING SWITCH
INCOMING 3
6

CLOSE

OPEN

CLOSE

A
MT+

/Z1.3B

14

12
/Z1.5C

11

11

-KSW6

/Z1.5C

11

-KSW5

/Z1.5C

11

-KSW4

/Z1.5C

11

-KSW3

/Z1.5C

11

-KSW2

/Z1.6B

11

14

12

14

12

14

12

14

12

14

12

14

12

-KSW1
11

-KJ13
/Z1.7E

11

-KJ14
/Z1.7E

/N6.1A

10

/Z1.3B

12

-SQ5

14

12

MT+

/N4.8B

OFF-PUSH
OFF
ON
ON-PUSH

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

-D013
/Z2.1D

D
CBK+

/N4.8E

-H85

-H86

/Z2.3B

/Z2.3B

-H84
/Z2.3B
1

X2

-SQ5
/Z1.3B

/Z2.1D
A

X1

-D014
K

/N4.8D

CBK-

ES+

/N6.1E

Created with

-X100 22

/N4.8F

1L-

1L-

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


MV EQUIPMENT CHECK BACK INDICATION

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

N5

N6

=K00+W2
EARTHING SWITCH

13.8kV CONTROL PANEL 2

EARTHING SWITCH

OUTGOING TX-2
OPEN

OUTGOING TX-1

CLOSE

OPEN

CLOSE

-KSW10

/Z1.5D

/Z1.5D

14

12

-KSW9

/Z1.5D

11

-KSW8

/Z1.5C

11

-KSW7

B
11

14

12

14

12

14

MT+

12

/N5.8A

11

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

-H95
/Z2.3B

/N5.8E

-H94
/Z2.3B
1

ES+
52

53

54

Created with

-X100 51

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


MV EQUIPMENT CHECK BACK INDICATION

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

N6

R1

=K00+W2
AC/DC SUPPLY

13.8kV CONTROL PANEL 2

FAILURE

=E00+X2
COMMON PANEL

-X400 26

-X901 1

-F201
/Z2.5A

14

12

-F100
/Z2.6A

11

14

12

11

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

-X901 2

-X400 242

Created with

=E00+X2
COMMON PANEL

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


AC/DC SUPPLY FAILURE INDICATION

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

CIRCUIT DIAGRAM

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

R1

Z1

44

42

34

32

24

22

14

12

41

-KGR1

/M2.4C

/M3.6C

-KMC1

/M3.2E

/N1.2C

/N1.4C

/N1.6C

/N2.2C

-SG5

/N1.4D

/N1.4D

/N4.3C

/N4.4C

/N4.3E

-KGR2

/M2.5C

/M3.7C

-KMC2

/M3.2E

/N2.4C

/N2.6C

/N3.2C

/N1.2C

-SG6

/N1.6D

/N1.7D

/N4.4C

/N4.5C

/N4.4E

-KGR3

/M2.6C

/M3.7C

-KMC3

/M3.3E

/N1.4C

/N1.7C

/N2.2C

/N2.4C

-ST4

/N2.2D

/N2.2D

/N4.5C

/N4.6C

/N4.5E

-KMC4

/M3.3E

/N2.7C

/N3.2C

-ST5

/N2.4D

/N2.4D

/N4.6C

/N4.7C

/N4.6E

-KBC1

/M3.4E

/N1.3C

/N1.5C

/N1.7C

/N2.3C

-SQ4

/N2.6D

/N2.7D

/N4.7C

/N4.8C

/N4.7E

-KBC2

/M3.4E

/N2.5C

/N2.7C

/N3.3C

/N1.3C

-SQ5

/N3.2D

/N3.2D

/N5.2C

/N5.3C

/N5.2E

/N2.3C

/N2.5C

X2

-KSW1

/M4.2D

/N5.5B

/M6.2D

-KBC3

/M3.5E

/N1.5C

/N1.7C

-KSW2

/M4.2E

/N5.6B

/M6.2D

-KBC4

/M3.5E

/N2.7C

/N3.3C

-KSW3

/M4.3D

/N5.6B

/M6.3D

-KJ01

/M1.2D

/N4.3B

/M5.2D

/M7.2D

-KSW4

/M4.3E

/N5.7B

/M6.3D

-KJ02

/M1.2E

/N4.2B

/M5.2D

/M7.2D

-KSW5

/M4.4D

/N5.7B

/M6.3D

-KJ03

/M1.3D

/N4.4B

/M5.2D

/M7.2D

-KSW6

/M4.4E

/N5.8B

/M6.4D

-KJ04

/M1.3E

/N4.3B

/M5.3D

/M7.3D

-KSW7

/M4.5D

/N6.2B

/M6.4D

-KJ05

/M1.4D

/N4.5B

/M5.3D

/M7.3D

-KSW8

/M4.5E

/N6.2B

/M6.5D

-KJ06

/M1.4E

/N4.4B

/M5.3D

/M7.3D

-KSW9

/M4.6D

/N6.3B

/M6.5D

-KJ07

/M1.5D

/N4.6B

/M5.4D

/M7.4D

-KSW10

/M4.6E

/N6.3B

/M6.5D

-KJ08

/M1.5E

/N4.5B

/M5.4D

/M7.4D

-KJ09

/M1.6D

/N4.7B

/M5.5D

/M7.5D

-KJ10

/M1.6E

/N4.6B

/M5.5D

/M7.5D

-KJ11

/M1.7D

/N4.8B

/M5.5D

/M7.5D

-KJ12

/M1.7E

/N4.7B

/M5.6D

/M7.6D

-KJ13

/M2.2D

/N5.3B

/M5.6D

/M7.6D

-KJ14

/M2.2E

/N5.2B

/M5.7D

/M7.7D

RXM4AB2FD

41

21

6A
WITH LED
31

44

42

34

32

24

22

14

12

RXM4AB2FD

A1

RXM4CB2F7

A2

/N4.2E

A2

/N4.3C

12

/N4.2C

10

/N1.2D

/N1.2D

-SG4

31

6A
WITH LED
21

ON

A1

44

42

34

32

24

22

14

5A
WITH LED

11

OFF

12

-SG4

41

ON

X1

11

7
OFF

-SG4

31

ON

-SG4

21

OFF

-SG4

11

-SG4

A1

-SG4

OFF-PUSH
OFF
ON
ON-PUSH

11

A2

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

-S401

/M3.2C

15

18

16

A1
A2

12

10

-S401
8

-S401
4

11

BCU

-S401
2

MIMIC

TIME RELAY
-KFL

/M3.4C

/N4.2E

/N4.2E

/M8.3D

/M8.2D

E
1

11

E
Ph
N

/D1.4D

-S101

/D1.3D

-H101

/D1.3E

2
-R101

-X101

/D1.4E

/D1.5E

Created with

-B101

12

PE

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


AUXILIARY EQUIPMENTS

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

COMPONENT LIST

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

Z1

Z2

14

12

14

12

/N4.2D

-H84

/N5.5E

-D02

/N4.2D

-H85

/N5.6E

-D03

/N4.3D

-H86

/N5.7E

-D04

/N4.3D

-H94

/N6.2E

-D05

/N4.4D

-H95

/N6.3E

-D06

/N4.4D

-D07

/N4.5D

-D08

/N4.5D

-D09

/N4.6D

-D010

/N4.6D

-D011

/N4.7D

-HG4

/M3.6E

-D012

/N4.7D

-HG5

/M3.7E

-D013

/N5.2D

-HG6

/M3.7E

-D014

/N5.2D

-F201

/E1.3D

-F100

/R1.2D

/D1.3B

11

11

I>

/R1.2D

-D01

I>
3

I>

Engineering Base Version : 6.3.1

This document is exclusively property of Schneider Electric and shall not be used or copied without authorization

D
-D015
-D016
-D017
-D018

Created with

F
Customer

BOB PT. BUMI SIAK PUSAKO PERTAMINA HULU

Project Name

: EUROASIATIC
Jl. Raya Daan Mogot No. 44, Jakarta Indonesia
: 28MW GTG POWER PLANT_CONTROL-2

Project No.

: JO400003626

13.8kV CONTROL PANEL 2


AUXILIARY EQUIPMENTS

Scale

A3
PT. SCHNEIDER INDONESIA

Format

RSM

Checked By REVI
Appr. By

Drawing No. : P98014-D-E-SC-013

COMPONENT LIST

NTS

Drawn By

IKIM

Date

Revision

7/9/2013

A1

Sheet

Next Sheet

Z2