R3 DEPROPANIZER

Components: C1 nC8
FP:
PengRobinson
Stream (Tower Feed)
T = 90 oF
P = 217.28 Psia
F = 100 lbmole/hr
xC1= 0.1955
xC2= 0.1462
xC3= 0.1058
xiC4= 0.1076
xnC4= 0.0983
xiC5= 0.0891
xnC5= 0.0768
xnC6= 0.0903
xnC7= 0.0517
xnC8= 0.0387
Column Distillation (Depropanizer)
N = 10
Inlet: TowerFeed (5)
Ovd: Ovhd (total Reflux)
Bttm: Bttms
CondQ dan RebQ
PReb = 205 psia, T = 200 oF (P = 0)
PCond = 200 psia, T = 40 oF (P = 0)
Spec:
Reflux Ratio, Condenser, Molar , 1 (active)
C3inBttms, Reboiler, Mole Fraction, Liquid, 2e-2, Propane (active)
Reboiler duty, Reboiler, 7.5e5 (est)

DEBUTHANIZER

Component:
FP :

C3, iC4, nC4, iButene, iC5, nC5, nC6, nC7, nC8


PengRobinson

Streams
Variable
Temperature (F)
Pressure (Psia)
Flow (lbmole/hr
xC3
xiC4
xnC4
xi-Butene
xiC5
xnC5
nC6
nC7
nC8

Feed1
300
207
247.8
0.028
0.2016
0.2122
0.2419
0.1368
0.1795
0
0
0

Feed2
140
206
145.9
0.0198
0.2124
0.2124
0.0104
0.1409
0.1409
0.0927
0.0942
0.0763

Distillation Column (Debutanizer)


n=15, standard
Inlet Streams
Feed2 (4)
Feed1 (8)
Ovhd:
Butanes
Bttm Outlets C5+
Pressure
PCond= 205, PReb= 206.7 psia, P= 0
Condenser:
Energy:

Full
QCond, QReb

Specs:
C5 in Top, Condenser, Mole Fraction, Liquid, 1.798e-2, iC5, nC5
Reboiler Duty, Reboiler, 7.364e6 BTU/hr.

LPG

Komponen: N2, CO2, C1, C2, C3, iC4, nC4


FP : PR
MIX-100
Inlets: Feed 1 dan Feed 2
Outlet: MixerOut
Parameter:
Equilize All
Variables
Temperature (F)
Pressure (psia)
Molar Flow (lbmol/h)
xN2
xCO2
xC1
xC2
xC3
xiC4
xnC4
Separator (InletSep)
Inlet: MixerOut
Ovd: SepVap
Bttm: SepLiq
Valve (SepValve)
Inlet: SepLiq

Feed1
60
600
658.8
0.01
0.01
0.6
0.2
0.1
0.04
0.04

Feed2
60
600
439.2
0.0179
0
0.6244
0.1666
0.1136
0.0431
0.0345

Outlet: SepExit
P = 25 psia
HE (Gas/Gas)
Tube: SepVap CoolGas (P = 10 psia, TCoolGas=43.96)
Shell: LTSVap SalesGas ((P = 10 psia)
Parameter:
Calculate Ft flow
Cooler (Chiller)
CoolGas Cold Gas (Energy: (C3Duty = 1.076e6 BTU/hr)
Separator (LTS)
Inlet: ColdGas
Ovd: LTSVap
Bttm: LTSLiq
Valve (LTSValve)
LTSLiq LTSExit (P = 5 psia)
MIX-101
Inlets: SepExit and LTSExit
Outlet: TowerInlet
Parameter:
Equilize All
Valve (TowerValve)
TowerInlet TowerIn (P = 363 psia)
Heater (Heater)
TowerIn TowerFeed (Energy: HeaterQ, P = 10psi, TTowerFeed = 24.66)
Distillation Column (DePropanizer)
N = 10
Inlet: TowerFeed (5)
Ovd: Ovhd (total Reflux)
Bttm: LiquidProd
CondDuty dan RebDuty
PReb = 202.4 psia, T = 200 oF (P = 0)
PCond = 201.8 psia, T = 40 oF (P = 0)
Spec:
Reflux Ratio, Condenser, Molar , 1 (active)
Propane Fraction, Reboiler, Mole Fraction, Liquid, 2e-2, Propane (active)
Overhead Vapor Rate, Ovhd, Molar, 219.6 (est)

Comp Loop

Component: C1, C2, C3, nC4, nC5, nC6, H2O


Fluid Package: PR
Valve 103
15 2,
T15 = 25 oC
P15 = 105 kPa
F = 290.55 kmol/h
xC1 = 0.9
xC2 = 0.05
xC3 = 0.02
xnC4 = 0.01
xnC5 = 0.005
xnC6 = 0.005
xH2O = 0.01
V100
2 17 (ovd)
16 (Bttm)
Mix100
Inlet: 17,1 3
K100: 3 4 (Q-100, eff. ad.= 72.053, P4=300 kPa)
E100: 4 5 (P = 0, T5 = 46.92)
MIX101: 5,6 7 (T6 = 25, M6 = 1000 Kg/h, xH2O = 1)

V101
7 10 (ovd), 8 (bttm)
Level (19.62%)
Tee100
10 11, 13 (Split 11 = 1)
Valve102
89
P9 = 257.6 kPa
Valve101
11 12 (P12 = 257.6 kPa)
RCY1
13 14 (F14=0)
Valve100
14 1
P1 = 98.3

Absorption Dehydration

Component: N2, CO2, H2S, C1, C2, C3, iC4, nC4, iC5, nC5, TEGlycol, H2O
Fluid package: PR
Stream Composition (mol fraction)
Name
Inlet Gas
TEG Feed
Water to
Make UP TEG
Saturate
N2
1.00e-003
CO2
2.84e-002
H2S
1.55e-002
C1
0.8989
C2
3.10e-002
C3
1.48e-002
iC4
5.90e-003
nC4
3.00e-003
iC5
1.00e-003
nC5
5.00e-004
TEGlycol
0.00000
0.99 (%wt)
0.99
H2O
0.00000
0.01
1
0.01
PVT Data
Name

Inlet Gas

TEG Feed

Temperature
(F)
Pressure (Psia)

85

120

900

900

Molar Flow
(lbmole/hr)

1098

8.044

Water to
Saturate

Gas+H2O
85

1.1

Name
Temperature
(F)
Pressure (Psia)

Regen Feed
220

MekeUp TEG
60

TEG To Pump

TEG Only
7

Water DewPt
7.556

895

895

16

Liq Flow
(bbl/d)
Name
Temperature
(F)
Pressure (Psia)

TEG to Recy
120

Saturate (Mixer)
Inlet: Inlet Gas
Water to Saturate
Outlet: Gas+H2O
Equalize All
FWKO (Separator)
Inlet: Gas+H2O
Outlet: Gas to contactor (Vapor)
Water Out
Volume : 70.63Ft3
Liq Level: 50%
T100 (Absorber Column)
Top Stage Inlet:
Bottom Stage Inlet:
Vapor Outlet:
Liquid Outlet:
Number of trays: 14
P1= 885.3 psig
Pn = 885.3 psig

TEG Feed
Gas To Contactor
Dry Gas
Rich TEG

VLV-100 (Valve)
Inlet: Rich TEG
OutLet: LPTEG
L/R Exch (HE)
Tube In:
Tube Out:

Regen Bttms
Lean from L/R

Pump Out

Shell In:
LP TEG
Shell Out:
Regen Feed
HE Design (End Point)
Tube side pressure drop: 0.1 psi
Shell side pressure drop: 10 psi
TEG Regenerator (Dist. Column, 1 stage )
Regen Bttms (Bottom)
Energy: Reb Q
Condenser (Full Reflux)
Sour Gas (Vap)
Energy: Cond Q
Design Spec
TEG bottoms (TEG in battoms, reboiler, liquid, mass fract, 0.99) (active
Reboiler Temperature 400 oF (active)
Reflux Ratio 3.00 (estimate)
Sour Gas Rate 329.4 lbmole/hr (estimate)

MakeUp (Mixer)
Inlet: Lean from L/R
MakeUp TEG
Outlet: TEG to pump
Equilize All
P-100 (Pump)
Inlet: TEG to pump
Outlet: Pump Out
Energy: Pump Q
Adiabatic Eff. 75%
E101 (HE)
Tube In:
Pump Out
Tube Out:
TEG to Recy
Shell In:
Dry Gas
Shell Out:
Sales Gas
HE Design (End Point)
Tube side pressure drop: 10 psi
Shell side pressure drop: 5 psi
Remove TEG (Component Splitter)
Inlet: Sales Gas
Outlet: TEG Only (Ovd)
Water DewPt (Bttm)

Energy: Split Q
Split All zero except TEG Only=1
V-101 (Separator)
Inlet: Water DewPt
Out:

Gas Out (Vap)


XS H2O (Liq)
Vol. 70.63 ft3
Adjust
Adjust Variable: Water DewPt Temperatur
Object Variable: XS H2O (Comp Mass Flow) = 0.02 lb/hr
RCY-1 (Recycle)
Inlet: TEG To Recy
Outlet: TEG Feed